Yuen Albert W (15 results)

- Softcover
Seller: GreatBookPrices, Columbia, MD, U.S.A.GreatBookPrices
Contact seller5-star sellerCondition: New
£ 65.39
£ 1.93 shippingShips within U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: Rarewaves.com USA, London, LONDO, United KingdomRarewaves.com USA
Contact seller5-star sellerCondition: New
£ 69.42
Free ShippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Paperback. Condition: New.

- Softcover
Seller: GreatBookPrices, Columbia, MD, U.S.A.GreatBookPrices
Contact seller5-star sellerCondition: Used - As new
£ 69.56
£ 1.93 shippingShips within U.S.A.Quantity: Over 20 available
Condition: As New. Unread book in perfect condition.

- Softcover
Seller: California Books, Miami, FL, U.S.A.California Books
Contact seller4-star sellerCondition: New
£ 73.97
Free ShippingShips within U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: Ria Christie Collections, Uxbridge, United KingdomRia Christie Collections
Contact seller5-star sellerCondition: New
£ 63.48
£ 11.98 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Condition: New. In.

- Softcover
Seller: GreatBookPricesUK, Woodford Green, United KingdomGreatBookPricesUK
Contact seller5-star sellerCondition: New
£ 63.47
£ 15.00 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: GreatBookPricesUK, Woodford Green, United KingdomGreatBookPricesUK
Contact seller5-star sellerCondition: Used - As new
£ 69.64
£ 15.00 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Condition: As New. Unread book in perfect condition.

Language: English
Published by VDM Verlag Dr. Müller|VDM Verlag Dr. Müller e.K., 2008
- Softcover
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 72.31
£ 41.91 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Kartoniert / Broschiert. Condition: New. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector elec.

- Softcover
Seller: Rarewaves.com UK, London, United KingdomRarewaves.com UK
Contact seller5-star sellerCondition: New
£ 63.49
£ 65.00 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Book. Condition: New.

Language: English
Published by VDM Verlag Dr. Müller, VDM Verlag Dr. Müller E.K., 2008
- Softcover
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 86.28
£ 52.91 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. Neuware - Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collector current d…ensity in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distributed corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers.

- Softcover
Seller: Buchpark, Trebbin, GermanyBuchpark
Contact seller5-star sellerCondition: Used - Fine
£ 77.18
£ 89.83 shippingShips from Germany to U.S.A.Quantity: 1 available
Condition: Sehr gut. Zustand: Sehr gut | Sprache: Englisch | Produktart: Bücher | Keine Beschreibung verfügbar.

- Softcover
- Print on Demand
Seller: Grand Eagle Retail, Bensenville, IL, U.S.A.Grand Eagle Retail
Contact seller5-star sellerCondition: New
£ 67.38
Free ShippingShips within U.S.A.Quantity: 1 available
Paperback. Condition: new. Paperback. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collec-tor current d…ensity in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distri-buted corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collector current density in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distributed corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability.

- Softcover
- Print on Demand
Seller: PBShop.store US, Wood Dale, IL, U.S.A.PBShop.store US
Contact seller5-star sellerCondition: New
£ 67.94
Free ShippingShips within U.S.A.Quantity: Over 20 available
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Softcover
- Print on Demand
Seller: PBShop.store UK, Fairford, GLOS, United KingdomPBShop.store UK
Contact seller5-star sellerCondition: New
£ 64.33
£ 4.16 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
PAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Softcover
- Print on Demand
Seller: CitiRetail, Stevenage, United KingdomCitiRetail
Contact seller5-star sellerCondition: New
£ 68.99
£ 37.00 shippingShips from United Kingdom to U.S.A.Quantity: 1 available
Paperback. Condition: new. Paperback. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collec-tor current d…ensity in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distri-buted corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. Deutsch collection theory was developed for tubular geometry and applied to wire-plate ESP without taking into account the differences in geometry and current density distribution. Investigations revealed a square law relationship between the collector electric field and collector current density in space charge dominated coronas. Applying this relationship to Deutsch collection theory led to a new collection formula which is used to assess the impact on ESP performance due to the uneven current density distribution. A new concept of distributed corona impedance is developed to assess the effect of the dust layer on collection performance. It shows that optimal wire-plate ESP collection is obtained with the wire-wire spacing less than the wire-plate distance, confirming published experimental results. This is the first analytical approach to show better ESP collection performance can be achieved at the ratio of wire-wire spacing/wire-plate distance not equal to unity, which has been the industry practice since 1960. The analysis should shed some light on how ESP basic design could be changed and should be especially useful to ESP design professionals and researchers. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.