Language: English
Published by LAP Lambert Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: California Books, Miami, FL, U.S.A.
Condition: New.
Language: English
Published by LAP Lambert Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New.
Language: English
Published by LAP LAMBERT Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. HPLC-UV Method development for Fixed Dose Pharmaceutical Formulations | Analytical Method Development and Validation for selected Fixed-Dose Formulations Using HPLC and UV Spectroscopy | Sonia Yadav (u. a.) | Taschenbuch | Englisch | 2026 | LAP LAMBERT Academic Publishing | EAN 9786209779718 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu.
Language: English
Published by LAP LAMBERT Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.
Language: English
Published by LAP LAMBERT Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
£ 48.26
Quantity: Over 20 available
Add to basketPAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.
Language: English
Published by Omniscriptum, LAP Lambert Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Estimation of imeglimin hydrochloride in human plasma by HPLC-UV. The estimation of drugs by RP-HPLC (reverse phase chromatography) was chosen since it is advised for use with ionic and mild to non-polar compounds. Simple, specific, and superior in terms of efficiency, stability, and reproducibility is reverse phase chromatography. For the separation of imeglimin, the C18 column 250 x 4.6 mm, 5 µm particle size was chosen. In the mobile phase, various solvent solutions were tested and combined for optimum performance. Imeglimin hydrochloride (4 µg/ml) in buffer, pH 4 for Acetonitrile: Water (70:30), a concentration range (8-40 and 0.5-4 µg/ml) displaying excellent peak and a sizable resolution level. Having the mobile phase run at 1ml/min, photodiode array detectors were used to detect both analytes at 215 nm. The method was validated in different concentration ranges in human plasma. Imeglimin inter and intra-run precision was measured at less than 3.60% and had an accuracy of less than 1.869%. imeglimin in human plasma was validated by linearity, recovery matrix, and stability. The retention time of IMEG is 4.8 minutes in plasma. Suggested method denotes that it is cost-effective 52 pp. Englisch.
Language: English
Published by LAP Lambert Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand.
Language: English
Published by LAP Lambert Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND.
Language: English
Published by LAP Lambert Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. Estimation of imeglimin hydrochloride in human plasma by HPLC-UV. The estimation of drugs by RP-HPLC (reverse phase chromatography) was chosen since it is advised for use with ionic and mild to non-polar compounds. Simple, specific, and superior in terms of efficiency, stability, and reproducibility is reverse phase chromatography. For the separation of imeglimin, the C18 column 250 x 4.6 mm, 5 um particle size was chosen. In the mobile phase, various solvent solutions were tested and combined for optimum performance. Imeglimin hydrochloride (4 ug/ml) in buffer, pH 4 for Acetonitrile: Water (70:30), a concentration range (8-40 and 0.5-4 ug/ml) displaying excellent peak and a sizable resolution level. Having the mobile phase run at 1ml/min, photodiode array detectors were used to detect both analytes at 215 nm. The method was validated in different concentration ranges in human plasma. Imeglimin inter and intra-run precision was measured at less than 3.60% and had an accuracy of less than 1.869%. imeglimin in human plasma was validated by linearity, recovery matrix, and stability. The retention time of IMEG is 4.8 minutes in plasma. Suggested method denotes that it is cost-effective This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.
Language: English
Published by LAP LAMBERT Academic Publishing Mär 2026, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Estimation of imeglimin hydrochloride in human plasma by HPLC-UV. The estimation of drugs by RP-HPLC (reverse phase chromatography) was chosen since it is advised for use with ionic and mild to non-polar compounds. Simple, specific, and superior in terms of efficiency, stability, and reproducibility is reverse phase chromatography. For the separation of imeglimin, the C18 column 250 x 4.6 mm, 5 µm particle size was chosen. In the mobile phase, various solvent solutions were tested and combined for optimum performance. Imeglimin hydrochloride (4 µg/ml) in buffer, pH 4 for Acetonitrile: Water (70:30), a concentration range (8-40 and 0.5-4 µg/ml) displaying excellent peak and a sizable resolution level. Having the mobile phase run at 1ml/min, photodiode array detectors were used to detect both analytes at 215 nm. The method was validated in different concentration ranges in human plasma. Imeglimin inter and intra-run precision was measured at less than 3.60% and had an accuracy of less than 1.869%. imeglimin in human plasma was validated by linearity, recovery matrix, and stability. The retention time of IMEG is 4.8 minutes in plasma. Suggested method denotes that it is cost-effectiveVDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 52 pp. Englisch.
Language: English
Published by LAP LAMBERT Academic Publishing, 2026
ISBN 10: 6209779719 ISBN 13: 9786209779718
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Estimation of imeglimin hydrochloride in human plasma by HPLC-UV. The estimation of drugs by RP-HPLC (reverse phase chromatography) was chosen since it is advised for use with ionic and mild to non-polar compounds. Simple, specific, and superior in terms of efficiency, stability, and reproducibility is reverse phase chromatography. For the separation of imeglimin, the C18 column 250 x 4.6 mm, 5 µm particle size was chosen. In the mobile phase, various solvent solutions were tested and combined for optimum performance. Imeglimin hydrochloride (4 µg/ml) in buffer, pH 4 for Acetonitrile: Water (70:30), a concentration range (8-40 and 0.5-4 µg/ml) displaying excellent peak and a sizable resolution level. Having the mobile phase run at 1ml/min, photodiode array detectors were used to detect both analytes at 215 nm. The method was validated in different concentration ranges in human plasma. Imeglimin inter and intra-run precision was measured at less than 3.60% and had an accuracy of less than 1.869%. imeglimin in human plasma was validated by linearity, recovery matrix, and stability. The retention time of IMEG is 4.8 minutes in plasma. Suggested method denotes that it is cost-effective.