Seller: Basi6 International, Irving, TX, U.S.A.
Condition: Brand New. New.SoftCover International edition. Different ISBN and Cover image but contents are same as US edition.Expediting shipping for all USA and Europe orders excluding PO Box. Excellent Customer Service.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New.
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New.
Seller: Phatpocket Limited, Waltham Abbey, HERTS, United Kingdom
Condition: Good. Your purchase helps support Sri Lankan Children's Charity 'The Rainbow Centre'. Ex-library, so some stamps and wear, but in good overall condition. Our donations to The Rainbow Centre have helped provide an education and a safe haven to hundreds of children who live in appalling conditions.
hardcover. Condition: Gut. 642 Seiten; 9780824790028.3 Gewicht in Gramm: 2.
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
£ 117.99
Quantity: Over 20 available
Add to basketCondition: As New. Unread book in perfect condition.
Seller: Mispah books, Redhill, SURRE, United Kingdom
Paperback. Condition: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition.
Seller: BUCHSERVICE / ANTIQUARIAT Lars Lutzer, Wahlstedt, Germany
Condition: gut. 1995. Bioreactor System Design (Bioprocess Technology, Band 21) In englischer Sprache. pages.
Language: English
Published by CRC Press 1994-11-17, 1994
ISBN 10: 0824790022 ISBN 13: 9780824790028
Seller: Chiron Media, Wallingford, United Kingdom
Hardcover. Condition: New.
Condition: New.
Condition: As New. Unread book in perfect condition.
Condition: As New. Unread book in perfect condition.
Condition: New.
Language: English
Published by Taylor & Francis Group, 1994
ISBN 10: 0824790022 ISBN 13: 9780824790028
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. pp. 648.
Language: English
Published by Taylor & Francis Group, 1994
ISBN 10: 0824790022 ISBN 13: 9780824790028
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. pp. 648.
Gebunden. Condition: New. Juan A. AsenjoDescribes the state-of-the-art techniques and methods involved in the design, operation, preparation and containment of bioreactor systems, taking into account the interrelated effects of variables associated with both upstream and downstr.
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.
Language: English
Published by Diplomica Verlag Mrz 2011, 2011
ISBN 10: 3842858949 ISBN 13: 9783842858947
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Perfused bioreactors have been developed with different designs and with various cell lines such as fibroblasts, osteoblasts and C2C12 myoblasts. All these current systems are custom made and mostly capable for only one cell type. Small seeding spaces and chambers inhibit longer cell studies and the observation of cell interaction. This study presents an advanced perfusion bioreactor which allows cell observation for longer than 5 days on an area of 2.8cm2 with a volume of 17ml. Initial experiments investigated homogeneity of the heat distribution, which is precisely controlled and stable over the length of the experiment. The addition of perfusion to the system results in the manual feeding process with modified F12 nutrient media being unnecessary. The perfusion and perfusion rate are user controllable up to 8ml/h. Different inlets allow cell seeding, cell feeding and chemical stimulation.Since the metabolism by-products are diluted and removed by the flow of the perfused system, no inhibited growth occurs and the pH-value will maintain constant at 7.4 which removes the need for balancing the CO2 environment. Fully enclosed and sealed assemblies with a controlled hot plate can be used outside of the incubator and incorporated into the stage of a microscope to track and monitor cell growth.The bioreactor chamber consists of three parts of transparent annealed cast Acrylic plus sealing material. Acrylic is chosen since it is machinable by laser cutting, which is a fast and easy method of manufacture. Due to the annealing process sterilizing by ethanol is possible. Heat distribution analysis was made with an IR-camera. And the pH was tested by indicator paper. The flow rate was set at 3.3ml/h. Computer simulations for flow and heat distribution and standard tests with cell cultures showed that a round bioreactor chamber design has advantages due to more uniform conditions.To track the cells during their distribution and over their whole life cycle, a completely transparent system is being developed. It includes an Indium Tin Oxide (ITO) coated glass plate, which can be used as a hot plate with precise controlled heating properties to heat the whole chamber. 106 pp. Englisch.
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
£ 59.14
Quantity: Over 20 available
Add to basketPAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.
Language: English
Published by Diplomica Verlag GmbH, 2011
ISBN 10: 3842858949 ISBN 13: 9783842858947
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand pp. 108 466:B&W 7 x 10 in or 254 x 178 mm Perfect Bound on White w/Matte Lam.
Language: English
Published by Diplomica Verlag GmbH, 2011
ISBN 10: 3842858949 ISBN 13: 9783842858947
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Print on Demand pp. 108.
Language: English
Published by Diplomica Verlag GmbH, 2011
ISBN 10: 3842858949 ISBN 13: 9783842858947
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND pp. 108.
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Perfused bioreactors have been developed with different designs and with various cell lines such as fibroblasts, osteoblasts and C2C12 myoblasts. All these current systems are custom made and mostly capable for only one cell type. Small seeding spaces and c.
Language: English
Published by Diplomica Verlag, Diplomica Verlag Mär 2011, 2011
ISBN 10: 3842858949 ISBN 13: 9783842858947
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Perfused bioreactors have been developed with different designs and with various cell lines such as fibroblasts, osteoblasts and C2C12 myoblasts. All these current systems are custom made and mostly capable for only one cell type. Small seeding spaces and chambers inhibit longer cell studies and the observation of cell interaction. This study presents an advanced perfusion bioreactor which allows cell observation for longer than 5 days on an area of 2.8cm2 with a volume of 17ml. Initial experiments investigated homogeneity of the heat distribution, which is precisely controlled and stable over the length of the experiment. The addition of perfusion to the system results in the manual feeding process with modified F12 nutrient media being unnecessary. The perfusion and perfusion rate are user controllable up to 8ml/h. Different inlets allow cell seeding, cell feeding and chemical stimulation. Since the metabolism by-products are diluted and removed by the flow of the perfused system, no inhibited growth occurs and the pH-value will maintain constant at 7.4 which removes the need for balancing the CO2 environment. Fully enclosed and sealed assemblies with a controlled hot plate can be used outside of the incubator and incorporated into the stage of a microscope to track and monitor cell growth. The bioreactor chamber consists of three parts of transparent annealed cast Acrylic plus sealing material. Acrylic is chosen since it is machinable by laser cutting, which is a fast and easy method of manufacture. Due to the annealing process sterilizing by ethanol is possible. Heat distribution analysis was made with an IR-camera. And the pH was tested by indicator paper. The flow rate was set at 3.3ml/h. Computer simulations for flow and heat distribution and standard tests with cell cultures showed that a round bioreactor chamber design has advantages due to more uniform conditions. To track the cells during their distribution and over their whole life cycle, a completely transparent system is being developed. It includes an Indium Tin Oxide (ITO) coated glass plate, which can be used as a hot plate with precise controlled heating properties to heat the whole chamber.disserta Verlag, Hermannstal 119K, 22119 Hamburg 106 pp. Englisch.
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Perfused bioreactors have been developed with different designs and with various cell lines such as fibroblasts, osteoblasts and C2C12 myoblasts. All these current systems are custom made and mostly capable for only one cell type. Small seeding spaces and chambers inhibit longer cell studies and the observation of cell interaction. This study presents an advanced perfusion bioreactor which allows cell observation for longer than 5 days on an area of 2.8cm2 with a volume of 17ml. Initial experiments investigated homogeneity of the heat distribution, which is precisely controlled and stable over the length of the experiment. The addition of perfusion to the system results in the manual feeding process with modified F12 nutrient media being unnecessary. The perfusion and perfusion rate are user controllable up to 8ml/h. Different inlets allow cell seeding, cell feeding and chemical stimulation.Since the metabolism by-products are diluted and removed by the flow of the perfused system, no inhibited growth occurs and the pH-value will maintain constant at 7.4 which removes the need for balancing the CO2 environment. Fully enclosed and sealed assemblies with a controlled hot plate can be used outside of the incubator and incorporated into the stage of a microscope to track and monitor cell growth.The bioreactor chamber consists of three parts of transparent annealed cast Acrylic plus sealing material. Acrylic is chosen since it is machinable by laser cutting, which is a fast and easy method of manufacture. Due to the annealing process sterilizing by ethanol is possible. Heat distribution analysis was made with an IR-camera. And the pH was tested by indicator paper. The flow rate was set at 3.3ml/h. Computer simulations for flow and heat distribution and standard tests with cell cultures showed that a round bioreactor chamber design has advantages due to more uniform conditions.To track the cells during their distribution and over their whole life cycle, a completely transparent system is being developed. It includes an Indium Tin Oxide (ITO) coated glass plate, which can be used as a hot plate with precise controlled heating properties to heat the whole chamber.
Language: English
Published by Taylor & Francis Group, 1994
ISBN 10: 0824790022 ISBN 13: 9780824790028
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. pp. 648 This item is printed on demand.