Majeed Marw (9 results)

- Softcover
Seller: Books Puddle, New York, NY, U.S.A.Books Puddle
Contact seller4-star sellerCondition: New
£ 81.15
£ 2.92 shippingShips within U.S.A.Quantity: 4 available
Condition: New.

- Softcover
Seller: Revaluation Books, Exeter, United KingdomRevaluation Books
Contact seller5-star sellerCondition: New
£ 90.72
£ 10.00 shippingShips from United Kingdom to U.S.A.Quantity: 1 available
Paperback. Condition: Brand New. 136 pages. 8.66x5.91x0.31 inches. In Stock.

- Softcover
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 47.01
£ 59.94 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Bahavior of Reinforced Concrete Flat Plate with Shearhead Reinforcement | Marw Majeed (u. a.) | Taschenbuch | 136 S. | Englisch | 2019 | LAP LAMBERT Academic Publishing | EAN 9786200002891 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]…de | Anbieter: preigu.

Language: English
Published by LAP LAMBERT Academic Publishing Apr 2019, 2019
- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 54.60
£ 19.70 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -An experimental investigation was presented to evaluate static and repeated response of flat plate slabs reinforced by shearhead system. Fifteen panels were cast and tested under centrally point load. The slabs were geometrically si…milar (1000x1000x80) mm. The studied parameters are divided into shape of shearhead, section depth of shearhead, diameter of shearhead and number of stiffeners. The experimental results indicated that using square shearhead achieved slight increase in punching shear strength about 3% over that circular shearhead with same surface area. When increase the section depth of shearhead is increased from 30 mm to 40mm, the punching shear strength was increased about 32.7%. Increasing the number of stiffeners from one stiffener to two stiffener results a decrease in punching shear strength by about 20.3%. Under repeated load testing, there was an increase in punching shear strength when using shearhead reinforcement with 25%. When comparison between static and repeated load test was made, there was an increase in stiffness and ductility in specimens tested under static loading than specimens tested under repeated load. 136 pp. Englisch.

- Softcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 44.68
£ 41.95 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Majeed MarwMarw M. Majeed: Studied BSC in Civil Engineering at Nahrain University and completed MSC at Mustansiriyah University. Older Engineer in engineering section in an agricultural company, Iraq.An… experimental investigatio.

- Softcover
- Print on Demand
Seller: Majestic Books, Hounslow, United KingdomMajestic Books
Contact seller4-star sellerCondition: New
£ 82.39
£ 6.50 shippingShips from United Kingdom to U.S.A.Quantity: 4 available
Condition: New. Print on Demand.

- Softcover
- Print on Demand
Seller: Biblios, frankfurt am main, HESSE, GermanyBiblios
Contact seller4-star sellerCondition: New
£ 88.08
£ 8.52 shippingShips from Germany to U.S.A.Quantity: 4 available
Condition: New. PRINT ON DEMAND.

Language: English
Published by LAP LAMBERT Academic Publishing Apr 2019, 2019
- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 54.60
£ 51.38 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -An experimental investigation was presented to evaluate static and repeated response of flat plate slabs reinforced by shearhead system. Fifteen panels were cast and tested under centrally point load. The slabs were geometrically simila…r (1000x1000x80) mm. The studied parameters are divided into shape of shearhead, section depth of shearhead, diameter of shearhead and number of stiffeners. The experimental results indicated that using square shearhead achieved slight increase in punching shear strength about 3% over that circular shearhead with same surface area. When increase the section depth of shearhead is increased from 30 mm to 40mm, the punching shear strength was increased about 32.7%. Increasing the number of stiffeners from one stiffener to two stiffener results a decrease in punching shear strength by about 20.3%. Under repeated load testing, there was an increase in punching shear strength when using shearhead reinforcement with 25%. When comparison between static and repeated load test was made, there was an increase in stiffness and ductility in specimens tested under static loading than specimens tested under repeated load.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 136 pp. Englisch.

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 55.25
£ 52.33 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - An experimental investigation was presented to evaluate static and repeated response of flat plate slabs reinforced by shearhead system. Fifteen panels were cast and tested under centrally point load. The slabs were geometrically similar… (1000x1000x80) mm. The studied parameters are divided into shape of shearhead, section depth of shearhead, diameter of shearhead and number of stiffeners. The experimental results indicated that using square shearhead achieved slight increase in punching shear strength about 3% over that circular shearhead with same surface area. When increase the section depth of shearhead is increased from 30 mm to 40mm, the punching shear strength was increased about 32.7%. Increasing the number of stiffeners from one stiffener to two stiffener results a decrease in punching shear strength by about 20.3%. Under repeated load testing, there was an increase in punching shear strength when using shearhead reinforcement with 25%. When comparison between static and repeated load test was made, there was an increase in stiffness and ductility in specimens tested under static loading than specimens tested under repeated load.