Haldar Putul (7 results)

Author
Refine with Advanced Search

Refine your search

  • Books (7)

  • New (7)

to

Custom price range (£)

to

    • Condition: New

      £ 84.93

      £ 10.00 shipping 
      Ships from United Kingdom to U.S.A.

      Quantity: 1 available

      Paperback. Condition: Brand New. 112 pages. 8.66x5.91x0.26 inches. In Stock.

    • Language: English

      Published by LAP LAMBERT Academic Publishing, 2012

      3659250961 / 9783659250965

      • Softcover

      Seller: Mispah books, Redhill, SURRE, United KingdomMispah books

      4-star seller
      Contact seller

      Condition: New

      £ 143.00

      £ 25.00 shipping 
      Ships from United Kingdom to U.S.A.

      Quantity: 1 available

      paperback. Condition: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

    • Language: English

      Published by LAP LAMBERT Academic Publishing, 2012

      3659250961 / 9783659250965

      • Softcover

      Seller: preigu, Osnabrück, Germanypreigu

      5-star seller
      Contact seller

      Condition: New

      £ 173.12

      £ 60.03 shipping 
      Ships from Germany to U.S.A.

      Quantity: 5 available

      Taschenbuch. Condition: Neu. Seismic Performance and Vulnerability of Indian RC Frame Buildings | Seismic performance evaluation of RC frame buildings with and without infills, designed for Indian codes | Putul Haldar (u. a.) | Taschenbuch | 112 S. | Englisch | 2012 | LAP LAMBERT Academic Publishing | EAN 9783659250965 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

    • Language: English

      Published by LAP LAMBERT Academic Publishing Okt 2012, 2012

      3659250961 / 9783659250965

      • Softcover
      • Print on Demand

      Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

      5-star seller
      Contact seller

      Condition: New

      £ 43.28

      £ 19.72 shipping 
      Ships from Germany to U.S.A.

      Quantity: 2 available

      Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Current seismic design practice in India is based on force-based design philosophy, with partial incorporation of capacity design concepts. In the present study, adequacy of this philosophy and relative importance of various code provisions are examined by estimating the expected performance of a set of code-designed buildings, with and without URM infills, in deterministic and probabilistic terms. It is shown that the current form of the Indian standard provisions for the control of interstorey drift leads to many discrepancies. Special Moment-Resisting Frame (SMRF) under the current design provisions of Indian standards has a higher probability of damage, as compared with the Ordinary Moment-Resisting Frame (OMRF). This discrepancy is due to the specification of interstorey drift limit at the design loads, which results in different effective limits on the inelastic drifts in the cases of OMRF and SMRF. Performance of SMRF design is improved significantly, particularly at the higher ground shaking levels, by controlling the inelastic drift. Therefore, the current provision of Indian standard IS 1893 (2002) regarding the limit on interstorey drift needs revision. 112 pp. Englisch.

    • Language: English

      Published by LAP LAMBERT Academic Publishing, 2012

      3659250961 / 9783659250965

      • Softcover
      • Print on Demand

      Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

      5-star seller
      Contact seller

      Condition: New

      £ 43.28

      £ 26.15 shipping 
      Ships from Germany to U.S.A.

      Quantity: 1 available

      Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Current seismic design practice in India is based on force-based design philosophy, with partial incorporation of capacity design concepts. In the present study, adequacy of this philosophy and relative importance of various code provisions are examined by estimating the expected performance of a set of code-designed buildings, with and without URM infills, in deterministic and probabilistic terms. It is shown that the current form of the Indian standard provisions for the control of interstorey drift leads to many discrepancies. Special Moment-Resisting Frame (SMRF) under the current design provisions of Indian standards has a higher probability of damage, as compared with the Ordinary Moment-Resisting Frame (OMRF). This discrepancy is due to the specification of interstorey drift limit at the design loads, which results in different effective limits on the inelastic drifts in the cases of OMRF and SMRF. Performance of SMRF design is improved significantly, particularly at the higher ground shaking levels, by controlling the inelastic drift. Therefore, the current provision of Indian standard IS 1893 (2002) regarding the limit on interstorey drift needs revision.

    • Language: English

      Published by LAP LAMBERT Academic Publishing, 2012

      3659250961 / 9783659250965

      • Softcover
      • Print on Demand

      Seller: moluna, Greven, Germanymoluna

      5-star seller
      Contact seller

      Condition: New

      £ 36.81

      £ 42.01 shipping 
      Ships from Germany to U.S.A.

      Quantity: Over 20 available

      Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Haldar PutulMs. Putul Haldar (Chartered Engineer)is working as Fellow B on Indo-Norwegian collaborative research project Earthquake Hazard and Risk Reduction on the Indian Subcontinent .Dr. Yogendra Singh (Ph.D.) is Associate Prof.

    • Language: English

      Published by LAP LAMBERT Academic Publishing Okt 2012, 2012

      3659250961 / 9783659250965

      • Softcover
      • Print on Demand

      Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

      5-star seller
      Contact seller

      Condition: New

      £ 173.12

      £ 51.45 shipping 
      Ships from Germany to U.S.A.

      Quantity: 1 available

      Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Current seismic design practice in India is based on force-based design philosophy, with partial incorporation of capacity design concepts. In the present study, adequacy of this philosophy and relative importance of various code provisions are examined by estimating the expected performance of a set of code-designed buildings, with and without URM infills, in deterministic and probabilistic terms. It is shown that the current form of the Indian standard provisions for the control of interstorey drift leads to many discrepancies. Special Moment-Resisting Frame (SMRF) under the current design provisions of Indian standards has a higher probability of damage, as compared with the Ordinary Moment-Resisting Frame (OMRF). This discrepancy is due to the specification of interstorey drift limit at the design loads, which results in different effective limits on the inelastic drifts in the cases of OMRF and SMRF. Performance of SMRF design is improved significantly, particularly at the higher ground shaking levels, by controlling the inelastic drift. Therefore, the current provision of Indian standard IS 1893 (2002) regarding the limit on interstorey drift needs revision.OmniScriptum SRL, Str. Armeneasca 28/1, office 1, 2012 Chisinau 112 pp. Englisch.