Language: English
Published by LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: Hawking Books, Edgewood, TX, U.S.A.
Condition: Very Good. Very Good Condition. Tight and Neat. Five star seller - Buy with confidence!
Language: English
Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. pp. 128.
Language: English
Published by LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: Mispah books, Redhill, SURRE, United Kingdom
Paperback. Condition: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book.
Language: English
Published by LAP LAMBERT Academic Publishing Apr 2011, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -I describe a system to study the relation between cardiac stroke volume and intracardiac bioimpedance signal. The system is a MATLAB based software composed of 3D dynamic heart modelling part and impedance signal simulation part. This system allows to conduct virtual experiments with dynamic heart models that can be designed with characteristics of real dynamic hearts. The simulation part computes the bioimpedance signal with Finite Difference Method. Electrode locations can be specified anywhere in the virtual heart and the FDM computes the complex electrical potential in the whole modelling domain. This method effectively gives the solution to the forward problem of electrical bioimpedance. Sample results of the working system are presented as simulated complex impedance signals at the catheter electrodes with 5 different stroke volumes of the heart and at 2 different frequencies. The results show that magnitude and also phase of the signal correlate with the changing volume of the heart. The impedance of static heart with anisotropic tissue properties was also studied and it uncovered the extent of errors that improper use of anisotropy could introduce. 128 pp. Englisch.
Language: English
Published by LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: moluna, Greven, Germany
Kartoniert / Broschiert. Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Gordon RaunoRauno Gordon graduated Tallinn University of Technology with a degree in physics in 2000 and continued research in the Institute of Electronics. In 2007 he defended his PhD in the field of bioimpedance and computer simula.
Language: English
Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand pp. 128 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam.
Language: English
Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND pp. 128.
Language: English
Published by LAP LAMBERT Academic Publishing Apr 2011, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -I describe a system to study the relation between cardiac stroke volume and intracardiac bioimpedance signal. The system is a MATLAB based software composed of 3D dynamic heart modelling part and impedance signal simulation part. This system allows to conduct virtual experiments with dynamic heart models that can be designed with characteristics of real dynamic hearts. The simulation part computes the bioimpedance signal with Finite Difference Method. Electrode locations can be specified anywhere in the virtual heart and the FDM computes the complex electrical potential in the whole modelling domain. This method effectively gives the solution to the forward problem of electrical bioimpedance. Sample results of the working system are presented as simulated complex impedance signals at the catheter electrodes with 5 different stroke volumes of the heart and at 2 different frequencies. The results show that magnitude and also phase of the signal correlate with the changing volume of the heart. The impedance of static heart with anisotropic tissue properties was also studied and it uncovered the extent of errors that improper use of anisotropy could introduce.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 128 pp. Englisch.
Language: English
Published by LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Virtual Heart | Modelling of Cardiac Dynamics and Intracardiac Bioimpedance | Rauno Gordon | Taschenbuch | 128 S. | Englisch | 2011 | LAP LAMBERT Academic Publishing | EAN 9783838370644 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand.
Language: English
Published by LAP LAMBERT Academic Publishing, 2011
ISBN 10: 3838370643 ISBN 13: 9783838370644
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - I describe a system to study the relation between cardiac stroke volume and intracardiac bioimpedance signal. The system is a MATLAB based software composed of 3D dynamic heart modelling part and impedance signal simulation part. This system allows to conduct virtual experiments with dynamic heart models that can be designed with characteristics of real dynamic hearts. The simulation part computes the bioimpedance signal with Finite Difference Method. Electrode locations can be specified anywhere in the virtual heart and the FDM computes the complex electrical potential in the whole modelling domain. This method effectively gives the solution to the forward problem of electrical bioimpedance. Sample results of the working system are presented as simulated complex impedance signals at the catheter electrodes with 5 different stroke volumes of the heart and at 2 different frequencies. The results show that magnitude and also phase of the signal correlate with the changing volume of the heart. The impedance of static heart with anisotropic tissue properties was also studied and it uncovered the extent of errors that improper use of anisotropy could introduce.