Fathy Marzouk (7 results)

- Softcover
Seller: Revaluation Books, Exeter, United KingdomRevaluation Books
Contact seller5-star sellerCondition: New
£ 79.24
£ 10.00 shippingShips from United Kingdom to U.S.A.Quantity: 1 available
Paperback. Condition: Brand New. 144 pages. 8.66x5.91x0.33 inches. In Stock.

- Softcover
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 40.96
£ 60.39 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Block Building Load Estimation | Fathy Marzouk | Taschenbuch | 144 S. | Englisch | 2016 | LAP LAMBERT Academic Publishing | EAN 9783659960215 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.

- Softcover
Seller: Mispah books, Redhill, SURRE, United KingdomMispah books
Contact seller4-star sellerCondition: New
£ 140.00
£ 25.00 shippingShips from United Kingdom to U.S.A.Quantity: 1 available
paperback. Condition: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book.

Language: English
Published by LAP LAMBERT Academic Publishing Sep 2016, 2016
- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 49.68
£ 19.84 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This research aims to talk about load calculation for any block building (office buildings, hotels, residential, .etc.) Heat transmission, sun load, equipment, number of persons.etc., all of these factors affect the load calculated…for any building. Equipment in air conditioning system should be known well as we selected the suitable equipment for our system. Components and types of primary refrigeration equipment (like chillers) affect the efficiency of our air conditioning system so we should to know what we are selecting for our system. Air movers (fans) should provide enough fresh air for persons according to type of activity so; they should have enough power to provide air. Piping system is very important to transport secondary refrigerant (chilled water) to air handlers. It should be designed well to reduce head that pumps should to overcome. 144 pp. Englisch.

- Softcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 41.04
£ 42.27 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Marzouk FathyMy name is Fathy Marzouk. I am mechanical Team leader working in mechanical field since 2006. I had finished my master in 2012 and PMP in 2013. Now i am preparing MBA.This research aims to…talk about load calculation.

Language: English
Published by LAP LAMBERT Academic Publishing Sep 2016, 2016
- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 49.68
£ 51.77 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This research aims to talk about load calculation for any block building (office buildings, hotels, residential, .etc.) Heat transmission, sun load, equipment, number of persons¿etc., all of these factors affect the load calculated for…any building. Equipment in air conditioning system should be known well as we selected the suitable equipment for our system. Components and types of primary refrigeration equipment (like chillers) affect the efficiency of our air conditioning system so we should to know what we are selecting for our system. Air movers (fans) should provide enough fresh air for persons according to type of activity so; they should have enough power to provide air. Piping system is very important to transport secondary refrigerant (chilled water) to air handlers. It should be designed well to reduce head that pumps should to overcome.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 144 pp. Englisch.

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 49.68
£ 52.77 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This research aims to talk about load calculation for any block building (office buildings, hotels, residential, .etc.) Heat transmission, sun load, equipment, number of persons.etc., all of these factors affect the load calculated for a…ny building. Equipment in air conditioning system should be known well as we selected the suitable equipment for our system. Components and types of primary refrigeration equipment (like chillers) affect the efficiency of our air conditioning system so we should to know what we are selecting for our system. Air movers (fans) should provide enough fresh air for persons according to type of activity so; they should have enough power to provide air. Piping system is very important to transport secondary refrigerant (chilled water) to air handlers. It should be designed well to reduce head that pumps should to overcome.