Chanda Souptick (39 results)

- Softcover
Seller: Books Puddle, Woodside, NY, U.S.A.Books Puddle
Contact seller4-star sellerCondition: New
£ 93.55
£ 3.02 shippingShips within U.S.A.Quantity: 4 available
Condition: New.

- Softcover
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 43.40
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New.

- Hardcover
Seller: Books Puddle, Woodside, NY, U.S.A.Books Puddle
Contact seller4-star sellerCondition: New
£ 150.23
£ 3.02 shippingShips within U.S.A.Quantity: 4 available
Condition: New.

- Hardcover
Seller: Revaluation Books, Exeter, United KingdomRevaluation Books
Contact seller5-star sellerCondition: New
£ 145.98
£ 12.50 shippingShips from United Kingdom to U.S.A.Quantity: 1 available
Hardcover. Condition: Brand New. 453 pages. 10.01x7.01x9.49 inches. In Stock.

- Hardcover
Seller: Home-set, Mannheim, GermanyHome-set
Contact seller5-star sellerCondition: New
£ 126.39
£ 41.62 shippingShips from Germany to U.S.A.Quantity: 2 available
Gebundene Ausgabe. Condition: Neu. This textbook serves as a comprehensive resource for readers interested in applying the principles of engineering mechanics to analyse the mechanical and structural functions of the musculoskeletal system. Over the past few decades, orthopaedic practice has strongly been influenced by the contributions from mechanical analysis and design. This book sequentially presents basic concepts and applications necessary for understanding a biomechanical system. The book is specially focussed on analysis and design of orthopaedic implants used to treat skeletal diseases and disorders. The book begins with an introduction to the anatomy, physiology, and movements of human body and its mechanical analogy, followed by chapters on basic biomechanics of various joints and spine. It elaborately discusses the gait analysis and measurement techniques and systematically presents the quantitative estimation of musculoskeletal forces (joint forces and moments, muscle forces) using the fundamental concepts of joint dynamics (kinematics and kinetics), with relevant solved examples and exercises to impart basic understanding and knowledge to the students. It also discusses the basic concepts of mechanics of deformable bodies relevant for bone tissue as well as implanted bone structure, common failure mechanisms of implanted bone structure and biomaterials used in orthopaedic implants, and the steps involved in finite element modelling and analysis of implant-bone structures. Other topics covered include various theories, mathematical formulations, the computational framework of bone remodelling and bone ingrowth, mechanobiology based mathematical models of tissue differentiation, and simulations on tissue ingrowth have been presented along with the outcomes of our research activities, which may help and inspire the students to pursue research in this field. Sprache: Englisch Gewicht in Gramm: 877.…

- Softcover
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 43.40
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 48.03
£ 58.39 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Optimisation de la forme de l'implant fémoral dans l'arthroplastie totale de la hanche | Approche par éléments finis à l'aide d'un réseau neuronal et d'algorithmes génétiques combinés | Souptick Chanda | Taschenbuch | Französisch | 2023 | Editions Notre Savoir | EAN 9786206365891 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu.…

- Softcover
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 43.40
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 43.40
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: Home-set, Mannheim, GermanyHome-set
Contact seller5-star sellerCondition: New
£ 55.76
£ 41.62 shippingShips from Germany to U.S.A.Quantity: 2 available
Softcover/Taschenbuch. Condition: Neu. Es ist bekannt, dass Versagensmechanismen wie implantatbedingter ung?nstiger Knochenumbau, ?berm??ige Spannungen an der Schnittstelle zwischen Implantat und Knochen und mangelnde Prim?rstabilit?t das Ergebnis der zementfreien H?fttotalendoprothese (HTEP) beeintr?chtigen. Es wird berichtet, dass diese Versagensmechanismen durch das Design des Femurimplantats beeinflusst werden. Mit Hilfe der Formoptimierung als pr?klinisches Designwerkzeug k?nnen Schaftgeometrien auf der Grundlage dieser Versagensziele bewertet werden. Diese Ziele k?nnen jedoch manchmal miteinander in Konflikt stehen. Daher ist es notwendig, eine multikriterielle Formoptimierung zu implementieren, um den Designkonflikt zu l?sen. Anhand eines patientenspezifischen Femurs und eines ersten Designs eines TriLock? (DePuy)-Schafts wurde ein vollautomatisches 3D-Formoptimierungsschema entwickelt, das auf der Minimierung des Knochenumbaus und der Schnittstellenspannungen basiert. In der Studie wurde nach weiteren kompromissf?higen Designs von Femurimplantaten gesucht, indem ein neuartiges hybrides System zur gleichzeitigen Minimierung aller drei Ziele eingef?hrt wurde. In der Studie wurden lateral aufgeweitete Designs mit rechteckigen proximalen Querschnitten und gr??eren Schaftgr??en zur Verbesserung der Stabilit?t bevorzugt. Die endg?ltigen Kompromiss-Schaftgeometrien sagten eine g?nstige Last?bertragung und verbesserte Fixierung voraus. De Gewicht in Gramm: 286. …

- Softcover
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 48.03
£ 58.39 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Otimização da forma do implante femoral na artroplastia total da anca | Uma abordagem de elementos finitos utilizando redes neurais combinadas e algoritmos genéticos | Souptick Chanda | Taschenbuch | Portugiesisch | 2023 | Edições Nosso Conhecimento | EAN 9786206365921 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu.…

- Softcover
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 55.76
£ 58.39 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Optimierung der Form des Femurimplantats in der Hüfttotalendoprothese | Ein Finite-Elemente-Ansatz unter Verwendung einer Kombination aus neuronalem Netz und genetischen Algorithmen | Souptick Chanda | Taschenbuch | 180 S. | Deutsch | 2023 | Verlag Unser Wissen | EAN 9786206365884 | Verantwortliche Person für die EU: SIA OmniScriptum Publishing, Brivibas Gatve 197, 1039 RIGA, LETTLAND, customerservice[at]vdm-vsg[dot]de | Anbieter: preigu.…

Language: English
Published by LAP LAMBERT Academic Publishing Jan 2017, 2017
- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 55.76
£ 19.19 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Failure mechanisms, such as implant-induced adverse bone remodelling, excessive implant-bone interface stresses and lack of primary stability, are known to affect the outcome of cementless Total Hip Arthroplasty (THA). These failure mechanisms are reported to be influenced by the design of femoral implant. Employing shape optimization as pre-clinical design tool, stem geometries can be evaluated based on these failure objectives. However, these objectives may sometimes be mutually conflicting. Hence, it is necessary to implement multi-objective shape optimization to tackle the design conflict. Using a patient-specific femur and an initial design of TriLock® (DePuy) stem, a fully-automated 3-D shape optimization scheme was developed based on minimization of bone remodelling and interface stresses. Further compromised designs of femoral implants were sought in study by introducing a novel hybrid framework for simultaneous minimization of all three objectives. The study favoured lateral-flared designs having rectangular proximal transverse sections and greater stem-sizes for improved stability. Final trade-off stem geometries predicted favourable load transfer and improved fixation. 172 pp. Englisch.…

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 55.76
£ 29.20 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Failure mechanisms, such as implant-induced adverse bone remodelling, excessive implant-bone interface stresses and lack of primary stability, are known to affect the outcome of cementless Total Hip Arthroplasty (THA). These failure mechanisms are reported to be influenced by the design of femoral implant. Employing shape optimization as pre-clinical design tool, stem geometries can be evaluated based on these failure objectives. However, these objectives may sometimes be mutually conflicting. Hence, it is necessary to implement multi-objective shape optimization to tackle the design conflict. Using a patient-specific femur and an initial design of TriLock® (DePuy) stem, a fully-automated 3-D shape optimization scheme was developed based on minimization of bone remodelling and interface stresses. Further compromised designs of femoral implants were sought in study by introducing a novel hybrid framework for simultaneous minimization of all three objectives. The study favoured lateral-flared designs having rectangular proximal transverse sections and greater stem-sizes for improved stability. Final trade-off stem geometries predicted favourable load transfer and improved fixation.…

- Softcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 45.45
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Chanda SouptickDr. Souptick Chanda was born on 28 January 1981 in India. After completing his Masters in Mechanical Engineering, he worked for two prominent corporate sectors. He did his PhD from IIT Kharagpur in 2015. After a short .…

Language: Spanish
Published by Ediciones Nuestro Conocimiento Aug 2023, 2023
- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 55.76
£ 19.19 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Se sabe que los mecanismos de fallo, como la remodelación ósea adversa inducida por el implante, las tensiones excesivas de la interfaz implante-hueso y la falta de estabilidad primaria, afectan al resultado de la artroplastia total de cadera (ATC) sin cemento. Estos mecanismos de fallo se ven influidos por el diseño del implante femoral. Empleando la optimización de la forma como herramienta de diseño preclínico, las geometrías de los vástagos pueden evaluarse en función de estos objetivos de fallo. Sin embargo, en ocasiones estos objetivos pueden entrar en conflicto. Por lo tanto, es necesario implementar la optimización de forma multiobjetivo para abordar el conflicto de diseño. Utilizando un fémur específico de un paciente y un diseño inicial de vástago TriLock® (DePuy), se desarrolló un esquema de optimización de forma tridimensional totalmente automatizado basado en la minimización de la remodelación ósea y las tensiones de interfaz. En el estudio se buscaron diseños más comprometidos de implantes femorales mediante la introducción de un novedoso marco híbrido para la minimización simultánea de los tres objetivos. El estudio favoreció los diseños de acampanado lateral con secciones transversales proximales rectangulares y vástagos de mayor tamaño para mejorar la estabilidad. Las geometrías finales del vástago predijeron una transferencia de carga favorable y una fijación mejorada. 176 pp. Spanisch.…

- Softcover
- Print on Demand
Seller: Majestic Books, Hounslow, United KingdomMajestic Books
Contact seller4-star sellerCondition: New
£ 96.54
£ 6.50 shippingShips from United Kingdom to U.S.A.Quantity: 4 available
Condition: New. Print on Demand.

- Softcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 62.63
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt.

- Softcover
- Print on Demand
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 47.38
£ 58.39 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Shape Optimization of Femoral Implant in Total Hip Arthroplasty | A Finite Element Approach Using Combined Neural Network and Genetic Algorithms | Souptick Chanda | Taschenbuch | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783659937330 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu Print on Demand.…

- Softcover
- Print on Demand
Seller: Biblios, frankfurt am main, HESSE, GermanyBiblios
Contact seller4-star sellerCondition: New
£ 98.28
£ 8.30 shippingShips from Germany to U.S.A.Quantity: 4 available
Condition: New. PRINT ON DEMAND.

Language: English
Published by LAP LAMBERT Academic Publishing Jan 2017, 2017
- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 55.76
£ 50.05 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Failure mechanisms, such as implant-induced adverse bone remodelling, excessive implant-bone interface stresses and lack of primary stability, are known to affect the outcome of cementless Total Hip Arthroplasty (THA). These failure mechanisms are reported to be influenced by the design of femoral implant. Employing shape optimization as pre-clinical design tool, stem geometries can be evaluated based on these failure objectives. However, these objectives may sometimes be mutually conflicting. Hence, it is necessary to implement multi-objective shape optimization to tackle the design conflict. Using a patient-specific femur and an initial design of TriLock® (DePuy) stem, a fully-automated 3-D shape optimization scheme was developed based on minimization of bone remodelling and interface stresses. Further compromised designs of femoral implants were sought in study by introducing a novel hybrid framework for simultaneous minimization of all three objectives. The study favoured lateral-flared designs having rectangular proximal transverse sections and greater stem-sizes for improved stability. Final trade-off stem geometries predicted favourable load transfer and improved fixation.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 172 pp. Englisch.…

- Hardcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 84.67
£ 40.87 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt.

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 62.95
£ 29.20 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Se sabe que los mecanismos de fallo, como la remodelación ósea adversa inducida por el implante, las tensiones excesivas de la interfaz implante-hueso y la falta de estabilidad primaria, afectan al resultado de la artroplastia total de cadera (ATC) sin cemento. Estos mecanismos de fallo se ven influidos por el diseño del implante femoral. Empleando la optimización de la forma como herramienta de diseño preclínico, las geometrías de los vástagos pueden evaluarse en función de estos objetivos de fallo. Sin embargo, en ocasiones estos objetivos pueden entrar en conflicto. Por lo tanto, es necesario implementar la optimización de forma multiobjetivo para abordar el conflicto de diseño. Utilizando un fémur específico de un paciente y un diseño inicial de vástago TriLock® (DePuy), se desarrolló un esquema de optimización de forma tridimensional totalmente automatizado basado en la minimización de la remodelación ósea y las tensiones de interfaz. En el estudio se buscaron diseños más comprometidos de implantes femorales mediante la introducción de un novedoso marco híbrido para la minimización simultánea de los tres objetivos. El estudio favoreció los diseños de acampanado lateral con secciones transversales proximales rectangulares y vástagos de mayor tamaño para mejorar la estabilidad. Las geometrías finales del vástago predijeron una transferencia de carga favorable y una fijación mejorada.…

- Hardcover
- Print on Demand
Seller: Majestic Books, Hounslow, United KingdomMajestic Books
Contact seller4-star sellerCondition: New
£ 157.37
£ 6.50 shippingShips from United Kingdom to U.S.A.Quantity: 4 available
Condition: New. Print on Demand.

- Hardcover
- Print on Demand
Seller: Biblios, frankfurt am main, HESSE, GermanyBiblios
Contact seller4-star sellerCondition: New
£ 161.29
£ 8.30 shippingShips from Germany to U.S.A.Quantity: 4 available
Condition: New. PRINT ON DEMAND.

- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 55.76
£ 19.19 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Les mécanismes de défaillance, tels que le remodelage osseux négatif induit par l'implant, les contraintes excessives à l'interface implant-os et le manque de stabilité primaire, sont connus pour affecter le résultat de l'arthroplastie totale de la hanche (ATH) sans ciment. Ces mécanismes de défaillance seraient influencés par la conception de l'implant fémoral. En utilisant l'optimisation de la forme comme outil de conception préclinique, les géométries de tige peuvent être évaluées sur la base de ces objectifs de défaillance. Cependant, ces objectifs peuvent parfois être mutuellement contradictoires. Il est donc nécessaire de mettre en oeuvre une optimisation de forme multi-objectifs pour résoudre le conflit de conception. En utilisant un fémur spécifique à un patient et une conception initiale de tige TriLock® (DePuy), un schéma d'optimisation de forme 3D entièrement automatisé a été développé sur la base de la minimisation du remodelage osseux et des contraintes d'interface. D'autres conceptions compromises d'implants fémoraux ont été recherchées dans l'étude en introduisant un nouveau cadre hybride pour la minimisation simultanée des trois objectifs. L'étude a favorisé les conceptions à évasement latéral ayant des sections transversales proximales rectangulaires et des tiges de plus grande taille pour une meilleure stabilité. Les géométries de tiges de compromis finales prévoyaient un transfert de charge favorable et une fixation améliorée. 172 pp. Französisch.…

Language: Spanish
Published by Ediciones Nuestro Conocimiento Aug 2023, 2023
- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 55.76
£ 50.05 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Se sabe que los mecanismos de fallo, como la remodelación ósea adversa inducida por el implante, las tensiones excesivas de la interfaz implante-hueso y la falta de estabilidad primaria, afectan al resultado de la artroplastia total de cadera (ATC) sin cemento. Estos mecanismos de fallo se ven influidos por el diseño del implante femoral. Empleando la optimización de la forma como herramienta de diseño preclínico, las geometrías de los vástagos pueden evaluarse en función de estos objetivos de fallo. Sin embargo, en ocasiones estos objetivos pueden entrar en conflicto. Por lo tanto, es necesario implementar la optimización de forma multiobjetivo para abordar el conflicto de diseño. Utilizando un fémur específico de un paciente y un diseño inicial de vástago TriLock® (DePuy), se desarrolló un esquema de optimización de forma tridimensional totalmente automatizado basado en la minimización de la remodelación ósea y las tensiones de interfaz. En el estudio se buscaron diseños más comprometidos de implantes femorales mediante la introducción de un novedoso marco híbrido para la minimización simultánea de los tres objetivos. El estudio favoreció los diseños de acampanado lateral con secciones transversales proximales rectangulares y vástagos de mayor tamaño para mejorar la estabilidad. Las geometrías finales del vástago predijeron una transferencia de carga favorable y una fijación mejorada.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 176 pp. Spanisch.…

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 62.95
£ 29.20 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Les mécanismes de défaillance, tels que le remodelage osseux négatif induit par l'implant, les contraintes excessives à l'interface implant-os et le manque de stabilité primaire, sont connus pour affecter le résultat de l'arthroplastie totale de la hanche (ATH) sans ciment. Ces mécanismes de défaillance seraient influencés par la conception de l'implant fémoral. En utilisant l'optimisation de la forme comme outil de conception préclinique, les géométries de tige peuvent être évaluées sur la base de ces objectifs de défaillance. Cependant, ces objectifs peuvent parfois être mutuellement contradictoires. Il est donc nécessaire de mettre en oeuvre une optimisation de forme multi-objectifs pour résoudre le conflit de conception. En utilisant un fémur spécifique à un patient et une conception initiale de tige TriLock® (DePuy), un schéma d'optimisation de forme 3D entièrement automatisé a été développé sur la base de la minimisation du remodelage osseux et des contraintes d'interface. D'autres conceptions compromises d'implants fémoraux ont été recherchées dans l'étude en introduisant un nouveau cadre hybride pour la minimisation simultanée des trois objectifs. L'étude a favorisé les conceptions à évasement latéral ayant des sections transversales proximales rectangulaires et des tiges de plus grande taille pour une meilleure stabilité. Les géométries de tiges de compromis finales prévoyaient un transfert de charge favorable et une fixation améliorée.…

- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 55.76
£ 50.05 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Les mécanismes de défaillance, tels que le remodelage osseux négatif induit par l'implant, les contraintes excessives à l'interface implant-os et le manque de stabilité primaire, sont connus pour affecter le résultat de l'arthroplastie totale de la hanche (ATH) sans ciment. Ces mécanismes de défaillance seraient influencés par la conception de l'implant fémoral. En utilisant l'optimisation de la forme comme outil de conception préclinique, les géométries de tige peuvent être évaluées sur la base de ces objectifs de défaillance. Cependant, ces objectifs peuvent parfois être mutuellement contradictoires. Il est donc nécessaire de mettre en uvre une optimisation de forme multi-objectifs pour résoudre le conflit de conception. En utilisant un fémur spécifique à un patient et une conception initiale de tige TriLock® (DePuy), un schéma d'optimisation de forme 3D entièrement automatisé a été développé sur la base de la minimisation du remodelage osseux et des contraintes d'interface. D'autres conceptions compromises d'implants fémoraux ont été recherchées dans l'étude en introduisant un nouveau cadre hybride pour la minimisation simultanée des trois objectifs. L'étude a favorisé les conceptions à évasement latéral ayant des sections transversales proximales rectangulaires et des tiges de plus grande taille pour une meilleure stabilité. Les géométries de tiges de compromis finales prévoyaient un transfert de charge favorable et une fixation améliorée.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 172 pp. Französisch.…

- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 55.76
£ 19.19 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Es ist bekannt, dass Versagensmechanismen wie implantatbedingter ungünstiger Knochenumbau, übermäßige Spannungen an der Schnittstelle zwischen Implantat und Knochen und mangelnde Primärstabilität das Ergebnis der zementfreien Hüfttotalendoprothese (HTEP) beeinträchtigen. Es wird berichtet, dass diese Versagensmechanismen durch das Design des Femurimplantats beeinflusst werden. Mit Hilfe der Formoptimierung als präklinisches Designwerkzeug können Schaftgeometrien auf der Grundlage dieser Versagensziele bewertet werden. Diese Ziele können jedoch manchmal miteinander in Konflikt stehen. Daher ist es notwendig, eine multikriterielle Formoptimierung zu implementieren, um den Designkonflikt zu lösen. Anhand eines patientenspezifischen Femurs und eines ersten Designs eines TriLock® (DePuy)-Schafts wurde ein vollautomatisches 3D-Formoptimierungsschema entwickelt, das auf der Minimierung des Knochenumbaus und der Schnittstellenspannungen basiert. In der Studie wurde nach weiteren kompromissfähigen Designs von Femurimplantaten gesucht, indem ein neuartiges hybrides System zur gleichzeitigen Minimierung aller drei Ziele eingeführt wurde. In der Studie wurden lateral aufgeweitete Designs mit rechteckigen proximalen Querschnitten und größeren Schaftgrößen zur Verbesserung der Stabilität bevorzugt. Die endgültigen Kompromiss-Schaftgeometrien sagten eine günstige Lastübertragung und verbesserte Fixierung voraus. 180 pp. Deutsch.…