Soft Computing Based Data Mining by Zadgaonkar a S (5 results)

Author: 
Title: 
Refine with Advanced Search

Refine your search

  • Books (5)

  • New (5)

to

Custom price range (£)

to

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2020

    6202676264 / 9786202676267

    • Softcover

    Seller: preigu, Osnabrück, Germanypreigu

    5-star seller
    Contact seller

    Condition: New

    £ 53.02

    £ 59.02 shipping 
    Ships from Germany to U.S.A.

    Quantity: 5 available

    Taschenbuch. Condition: Neu. SOFT-COMPUTING BASED DATA MINING | APPLIED FOR FAULT DIAGNOSIS AND RELIABILITY PROBLEMS EVALUATION IN POWER SYSTEM | A. S. Zadgaonkar (u. a.) | Taschenbuch | 192 S. | Englisch | 2020 | LAP LAMBERT Academic Publishing | EAN 9786202676267 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Jul 2020, 2020

    6202676264 / 9786202676267

    • Softcover
    • Print on Demand

    Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

    5-star seller
    Contact seller

    Condition: New

    £ 62.45

    £ 19.39 shipping 
    Ships from Germany to U.S.A.

    Quantity: 2 available

    Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In this thesis a noble method of fault locating in a radial power distribution system is discussed. Interval type-2 fuzzy system will ease the calculation involved. The history associated with fault occurred in power system can be effectively used as a strong database. This database will act as the trainer to the interval type-2 fuzzy expert system. A rich history of faulty area will enhance the performance of the interval type-2 Fuzzy Fault Identification System (IT2FFIS). Fault section location aims to identify the faulty area in the power system using the post fault status of protective relays and circuit breakers and diagnose the cause of a fault that has occurred. Restoration cost can be significantly reduced by accurately identifying a fault location and its cause, which also reduces the restoration time of the faulty section. In this thesis methodology based on interval type-2 fuzzy expert system is discussed for assistance to the operators for easy fault detection.The interval type-2 fuzzy sets are used here for data mining for fault location in the distribution system. 192 pp. Englisch.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2020

    6202676264 / 9786202676267

    • Softcover
    • Print on Demand

    Seller: moluna, Greven, Germanymoluna

    5-star seller
    Contact seller

    Condition: New

    £ 50.47

    £ 41.31 shipping 
    Ships from Germany to U.S.A.

    Quantity: Over 20 available

    Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Zadgaonkar A.S.Dr Arun Shrihari Zadgaonkar, a researcher and academician .He was awarded the Doctor of Literature (D.Litt) . He has published more than 400 research papers,3 Books,supervised more than 30 scholars,Own Indian Patents &.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2020

    6202676264 / 9786202676267

    • Softcover
    • Print on Demand

    Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

    5-star seller
    Contact seller

    Condition: New

    £ 68.93

    £ 29.51 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - In this thesis a noble method of fault locating in a radial power distribution system is discussed. Interval type-2 fuzzy system will ease the calculation involved. The history associated with fault occurred in power system can be effectively used as a strong database. This database will act as the trainer to the interval type-2 fuzzy expert system. A rich history of faulty area will enhance the performance of the interval type-2 Fuzzy Fault Identification System (IT2FFIS). Fault section location aims to identify the faulty area in the power system using the post fault status of protective relays and circuit breakers and diagnose the cause of a fault that has occurred. Restoration cost can be significantly reduced by accurately identifying a fault location and its cause, which also reduces the restoration time of the faulty section. In this thesis methodology based on interval type-2 fuzzy expert system is discussed for assistance to the operators for easy fault detection.The interval type-2 fuzzy sets are used here for data mining for fault location in the distribution system.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Jul 2020, 2020

    6202676264 / 9786202676267

    • Softcover
    • Print on Demand

    Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

    5-star seller
    Contact seller

    Condition: New

    £ 62.45

    £ 50.59 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In this thesis a noble method of fault locating in a radial power distribution system is discussed. Interval type-2 fuzzy system will ease the calculation involved. The history associated with fault occurred in power system can be effectively used as a strong database. This database will act as the trainer to the interval type-2 fuzzy expert system. A rich history of faulty area will enhance the performance of the interval type-2 Fuzzy Fault Identification System (IT2FFIS). Fault section location aims to identify the faulty area in the power system using the post fault status of protective relays and circuit breakers and diagnose the cause of a fault that has occurred. Restoration cost can be significantly reduced by accurately identifying a fault location and its cause, which also reduces the restoration time of the faulty section. In this thesis methodology based on interval type-2 fuzzy expert system is discussed for assistance to the operators for easy fault detection.The interval type-2 fuzzy sets are used here for data mining for fault location in the distribution system.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 192 pp. Englisch.…