Language: English
Published by VDM Verlag Dr. Müller, 2011
ISBN 10: 3639376773 ISBN 13: 9783639376777
Seller: Ria Christie Collections, Uxbridge, United Kingdom
£ 39.43
Quantity: Over 20 available
Add to basketCondition: New. In.
Language: English
Published by VDM Verlag Dr. M�ller 2011-08-11, 2011
ISBN 10: 3639376773 ISBN 13: 9783639376777
Seller: Chiron Media, Wallingford, United Kingdom
Paperback. Condition: New.
Language: English
Published by Plenum Press, New York & London, 1980
ISBN 10: 0306405512 ISBN 13: 9780306405518
Seller: Richard Booth's Bookshop, Hereford, United Kingdom
HardBack. Condition: Very Good. Dust Jacket Condition: Very Good. The boards and dust wrapper are in good condition- the back bottom corner of the board is bumped as is the top and tail of the spine. The spine of the dustwrapper is sunned to white. Light edge wear on the dust wrapper, heavier on the corners and top and tail of the spine.Binding tight and square, contents clean and unmarked.
£ 50.43
Quantity: Over 20 available
Add to basketCondition: New. In.
PF. Condition: New.
Condition: New. pp. 272.
Paperback. Condition: Brand New. reprint edition. 260 pages. 10.00x7.01x0.64 inches. In Stock.
Language: English
Published by VDM Verlag Dr. Müller, 2011
ISBN 10: 3639376773 ISBN 13: 9783639376777
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Fast Medical Image Reconstruction using Graphics Processing Unit | Towards Real-Time Reconstruction of Magnetic Resonance Images | Mohammad Nazmul Haque | Taschenbuch | Einband - flex.(Paperback) | Englisch | 2011 | VDM Verlag Dr. Müller | EAN 9783639376777 | Verantwortliche Person für die EU: OmniScriptum GmbH & Co. KG, Bahnhofstr. 28, 66111 Saarbrücken, info[at]akademikerverlag[dot]de | Anbieter: preigu.
Taschenbuch. Condition: Neu. Real-Time Medical Image Processing | Morio Onoe | Taschenbuch | xvi | Englisch | 2012 | Springer | EAN 9781475701234 | Verantwortliche Person für die EU: Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg, juergen[dot]hartmann[at]springer[dot]com | Anbieter: preigu.
Taschenbuch. Condition: Neu. Druck auf Anfrage Neuware - Printed after ordering - In order to rea1ize real-time medica1 imaging systems, such as are used for computed tomography, automated miscroscopy, dynamic radioisotope imaging, etc., special techno1ogy is required. The high-speed image sour ce must be successfu11y married with the u1tra high-speed computer. Usua11y the ordinary genera1-purpose computer is found to be inadequate to the image generation and/or image pro cessing task. The ordinary computer executes instructions at be tween 1 and 10 million per second. Speed has improved by only about a factor of 10 during the past 20 years. In contrast a typical com puter used in recognizing blood cell images at 10,000 per hour must execute instructions at between 1 billion and 10 billion per second. Simi1ar execution rates are required to construct a computed tomogra phy image in real-time (1 to 10 seconds). For the reasons given above, engineering development in image generation and processing in the field of biomedicine has become a discipline unto itself; a discipline wherein the computer engineer is driven to design extremely high-speed machines that far surpass the ordinary computer and the x-ray, radioisotope, or microscope scanner designer must also produce equipment whose specifications extend far beyond the state-of-the-art.
Language: English
Published by New York: Plenum 1980., 1981
ISBN 10: 0306405512 ISBN 13: 9780306405518
Seller: Mispah books, Redhill, SURRE, United Kingdom
hardcover. Condition: Acceptable. Acceptable. Dust Jacket NOT present. CD WILL BE MISSING. SHIPS FROM MULTIPLE LOCATIONS. book.
Seller: Brook Bookstore On Demand, Napoli, NA, Italy
Condition: new. Questo è un articolo print on demand.
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand pp. 272.
Language: English
Published by Springer, Springer Mai 2012, 2012
ISBN 10: 1475701233 ISBN 13: 9781475701234
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -In order to rea1ize real-time medica1 imaging systems, such as are used for computed tomography, automated miscroscopy, dynamic radioisotope imaging, etc., special techno1ogy is required. The high-speed image sour ce must be successfu11y married with the u1tra high-speed computer. Usua11y the ordinary genera1-purpose computer is found to be inadequate to the image generation and/or image pro cessing task. The ordinary computer executes instructions at be tween 1 and 10 million per second. Speed has improved by only about a factor of 10 during the past 20 years. In contrast a typical com puter used in recognizing blood cell images at 10,000 per hour must execute instructions at between 1 billion and 10 billion per second. Simi1ar execution rates are required to construct a computed tomogra phy image in real-time (1 to 10 seconds). For the reasons given above, engineering development in image generation and processing in the field of biomedicine has become a discipline unto itself; a discipline wherein the computer engineer is driven to design extremely high-speed machines that far surpass the ordinary computer and the x-ray, radioisotope, or microscope scanner designer must also produce equipment whose specifications extend far beyond the state-of-the-art. 272 pp. Englisch.
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND pp. 272.
Language: English
Published by Springer-Verlag New York Inc., 2012
ISBN 10: 1475701233 ISBN 13: 9781475701234
Seller: THE SAINT BOOKSTORE, Southport, United Kingdom
£ 57.65
Quantity: Over 20 available
Add to basketPaperback / softback. Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days.
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. General.- Towards an Image Analysis Center for Medicine.- 1. Introduction.- 2. The Interactive Image Analysis System.- 2.1 The Input Units.- 2.2 The Image Display System.- 2.3 The Computer System.- 3. The Computerized Microscope.- 3.1 The Input System.- 3.2.
Language: English
Published by VDM Verlag Dr. Müller, 2011
ISBN 10: 3639376773 ISBN 13: 9783639376777
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A fast magnetic resonance images (MRI) reconstruction algorithm taking advantage of the prevailing general purpose graphics processing unit (GPGPU) programming paradigm is experimented in this book. In a number of medical imaging modalities, the Fast Fourier Transform (FFT) is being used for the reconstruction of images from acquired raw data.The objective is to develop an algorithm to run under CPU and also in GPU for the reconstruction by performing the Fast Fourier Transform (FFT) as well as Inverse Fourier Transformation (IFT) in much faster way. The algorithm is developed in MATLAB environment. The CUFFT library is used to run under device to study the improved performance of reconstructions. GPUMat is used to running CUDA code in MATLAB. This book exercises the acceleration of MRI reconstruction algorithm on NVIDIA's GeForce G 103M based GPU and Intel® Core 2 Duo based CPU. Experimental FFT based reconstruction algorithm shows that GPU based MRI reconstruction achieved significant speedup compared to the CPUs for medical applications at a cheaper cost. The runtime for GPU shows that real-time MRI reconstruction will be possible.
Language: English
Published by Springer, Springer Mai 2012, 2012
ISBN 10: 1475701233 ISBN 13: 9781475701234
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -In order to rea1ize real-time medica1 imaging systems, such as are used for computed tomography, automated miscroscopy, dynamic radioisotope imaging, etc., special techno1ogy is required. The high-speed image sour ce must be successfu11y married with the u1tra high-speed computer. Usua11y the ordinary genera1-purpose computer is found to be inadequate to the image generation and/or image pro cessing task. The ordinary computer executes instructions at be tween 1 and 10 million per second. Speed has improved by only about a factor of 10 during the past 20 years. In contrast a typical com puter used in recognizing blood cell images at 10,000 per hour must execute instructions at between 1 billion and 10 billion per second. Simi1ar execution rates are required to construct a computed tomogra phy image in real-time (1 to 10 seconds). For the reasons given above, engineering development in image generation and processing in the field of biomedicine has become a discipline unto itself; a discipline wherein the computer engineer is driven to design extremely high-speed machines that far surpass the ordinary computer and the x-ray, radioisotope, or microscope scanner designer must also produce equipment whose specifications extend far beyond the state-of-the-art.Springer-Verlag KG, Sachsenplatz 4-6, 1201 Wien 272 pp. Englisch.