Method Development Validation Gas by Mishra Garima (12 results)

- Softcover
Seller: Ria Christie Collections, Uxbridge, United KingdomRia Christie Collections
Contact seller5-star sellerCondition: New
£ 44.10
£ 11.98 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Condition: New. In.

Language: English
Published by LAP LAMBERT Academic Publishing 2013-11-27, 2013
- Softcover
Seller: Chiron Media, Wallingford, United KingdomChiron Media
Contact seller5-star sellerCondition: New
£ 41.98
£ 15.49 shippingShips from United Kingdom to U.S.A.Quantity: 10 available
Paperback. Condition: New.

Language: English
Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2013
- Softcover
Seller: Books Puddle, New York, NY, U.S.A.Books Puddle
Contact seller4-star sellerCondition: New
£ 76.66
£ 2.98 shippingShips within U.S.A.Quantity: 4 available
Condition: New. pp. 96.

- Softcover
- Print on Demand
Seller: PBShop.store US, Wood Dale, IL, U.S.A.PBShop.store US
Contact seller5-star sellerCondition: New
£ 47.99
Free ShippingShips within U.S.A.Quantity: Over 20 available
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

- Softcover
- Print on Demand
Seller: PBShop.store UK, Fairford, GLOS, United KingdomPBShop.store UK
Contact seller5-star sellerCondition: New
£ 46.04
£ 3.29 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
PAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000.

Language: English
Published by LAP LAMBERT Academic Publishing Nov 2013, 2013
- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 48.18
£ 19.60 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical… ingredients (API). The analysis of residual organic solvents (methanol, ethanol, acetone and toluene) in Omeprazole API was investigated.The Head space gas chromatography (HSGC) method described in this investigation utilized a DB - 624, 30 m long x 0.32 mm internal diameter, 1.8 mim thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 180°C to prevent degradation. The initial oven temperature was set at 50°C for 10 min and programmed at a rate of 30°C min-1 to a final temperature of 200°C for 10 min. Nitrogen was used as a carrier gas and flame ionization detector was used. N,N-dimethyl formamide was selected as a diluent. The method was validated according to ICH guidelines and found to be specific, linear i.e.,C.C is 0.998,% RSD of each analyte is less than 8%, sensitive, rugged and showed excellent recovery. 96 pp. Englisch.

- Softcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 39.88
£ 41.74 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Mishra GarimaThe author is Garima Mishra D/o Kashi Prasad Mishra, has completed her B.Pharm (2006-2010) from Lloyd institute of management and technology, Gr. Noida with 75.3%. She has completed M.Pharm…a (Pharmaceutical Chemistry) fr.

Language: English
Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2013
- Softcover
- Print on Demand
Seller: Majestic Books, Hounslow, United KingdomMajestic Books
Contact seller4-star sellerCondition: New
£ 78.51
£ 6.50 shippingShips from United Kingdom to U.S.A.Quantity: 4 available
Condition: New. Print on Demand pp. 96 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam.

Language: English
Published by VDM Verlag Dr. Mueller Aktiengesellschaft & Co. KG, 2013
- Softcover
- Print on Demand
Seller: Biblios, frankfurt am main, HESSE, GermanyBiblios
Contact seller4-star sellerCondition: New
£ 81.26
£ 8.48 shippingShips from Germany to U.S.A.Quantity: 4 available
Condition: New. PRINT ON DEMAND pp. 96.

Language: English
Published by LAP LAMBERT Academic Publishing Nov 2013, 2013
- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 48.18
£ 51.12 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ing…redients (API). The analysis of residual organic solvents (methanol, ethanol, acetone and toluene) in Omeprazole API was investigated.The Head space gas chromatography (HSGC) method described in this investigation utilized a DB - 624, 30 m long x 0.32 mm internal diameter, 1.8 ¿m thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 180°C to prevent degradation. The initial oven temperature was set at 50°C for 10 min and programmed at a rate of 30°C min¿1 to a final temperature of 200°C for 10 min. Nitrogen was used as a carrier gas and flame ionization detector was used. N,N-dimethyl formamide was selected as a diluent. The method was validated according to ICH guidelines and found to be specific, linear i.e.,C.C is 0.998,% RSD of each analyte is less than 8%, sensitive, rugged and showed excellent recovery.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 96 pp. Englisch.
More images- Softcover
- Print on Demand
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 42.04
£ 59.64 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Method development and validation by Gas chromatography-HeadSpace | Garima Mishra (u. a.) | Taschenbuch | 96 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659492914 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[d…ot]de | Anbieter: preigu Print on Demand.

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 48.76
£ 51.81 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingr…edients (API). The analysis of residual organic solvents (methanol, ethanol, acetone and toluene) in Omeprazole API was investigated.The Head space gas chromatography (HSGC) method described in this investigation utilized a DB - 624, 30 m long x 0.32 mm internal diameter, 1.8 mim thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 180°C to prevent degradation. The initial oven temperature was set at 50°C for 10 min and programmed at a rate of 30°C min-1 to a final temperature of 200°C for 10 min. Nitrogen was used as a carrier gas and flame ionization detector was used. N,N-dimethyl formamide was selected as a diluent. The method was validated according to ICH guidelines and found to be specific, linear i.e.,C.C is 0.998,% RSD of each analyte is less than 8%, sensitive, rugged and showed excellent recovery.