Lvrt Stability Analysis Wgs by Phani Kumar (4 results)

Author: 
Title: 
Refine with Advanced Search

Refine your search

  • Books (4)

  • New (4)

to

Custom price range (£)

to

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2018

    6139887607 / 9786139887606

    • Softcover

    Seller: preigu, Osnabrück, Germanypreigu

    5-star seller
    Contact seller

    Condition: New

    £ 41.46

    £ 58.76 shipping 
    Ships from Germany to U.S.A.

    Quantity: 5 available

    Taschenbuch. Condition: Neu. LVRT and Stability Analysis of WGS Integrated to Microgrid | S. V. S. Phani Kumar Ch. (u. a.) | Taschenbuch | 92 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786139887606 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. …

  • Language: English

    Published by LAP LAMBERT Academic Publishing Jul 2018, 2018

    6139887607 / 9786139887606

    • Softcover
    • Print on Demand

    Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.

    5-star seller
    Contact seller

    Condition: New

    £ 47.47

    £ 19.31 shipping 
    Ships from Germany to U.S.A.

    Quantity: 2 available

    Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The Type-4 wind generation system integrated to Micro-grid through VSC-HVDC link is implemented and the analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. The present system considers the'Fault Ride Through' (FRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The VSC-HVDC based Type-4 Wind Generation System give more reliable to operate under FRT condition and can meet the Emergency Load demand when the system is under fault condition. 92 pp. Englisch.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing, 2018

    6139887607 / 9786139887606

    • Softcover
    • Print on Demand

    Seller: moluna, Greven, Germanymoluna

    5-star seller
    Contact seller

    Condition: New

    £ 39.30

    £ 41.13 shipping 
    Ships from Germany to U.S.A.

    Quantity: Over 20 available

    Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ch. S. V. S. Phani Kumar1st author received the B.Tech degree in Electrical Engg. from Nagarjuna University in 2008, received M.Tech degree in Power System Engineering from JNTU, Kakinada in year 2012. Since May 2014 working as an As.…

  • Language: English

    Published by LAP LAMBERT Academic Publishing Jul 2018, 2018

    6139887607 / 9786139887606

    • Softcover
    • Print on Demand

    Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000

    5-star seller
    Contact seller

    Condition: New

    £ 47.47

    £ 50.37 shipping 
    Ships from Germany to U.S.A.

    Quantity: 1 available

    Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The Type-4 wind generation system integrated to Micro-grid through VSC-HVDC link is implemented and the analysis is done by considering a fault on the grid side by the system gets isolated and wind generation system transfers voltage to local load and remote load. When a DC fault is occurred on the VSC-HVDC link then the grid side breaker and wind side breaker gets open, then system gets isolated. The present system considers the'Fault Ride Through' (FRT) conditions, According to the Indian grid code of contact wind generation maintain constant even the voltage collapse is occurred on the grid side. The VSC-HVDC based Type-4 Wind Generation System give more reliable to operate under FRT condition and can meet the Emergency Load demand when the system is under fault condition.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 92 pp. Englisch.…