Contingency Analysis Power System by Patel Niraj (6 results)
Contingency Analysis and Power System Security: Contingency Methods and Application of FACTS Devices
- Softcover
Seller: Revaluation Books, Exeter, United KingdomRevaluation Books
Contact seller5-star sellerCondition: New
£ 84.06
£ 10.00 shippingShips from United Kingdom to U.S.A.Quantity: 1 available
Paperback. Condition: Brand New. 124 pages. 8.66x5.91x0.28 inches. In Stock.
- More images
- Softcover
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 38.82
£ 59.90 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Contingency Analysis and Power System Security | Contingency Methods and Application of FACTS Devices | Niraj Patel (u. a.) | Taschenbuch | 124 S. | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783330073364 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848… Norderstedt, info[at]bod[dot]de | Anbieter: preigu.
- More images
Language: English
Published by LAP LAMBERT Academic Publishing Apr 2017, 2017
- Softcover
- Print on Demand
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
Contact seller5-star sellerCondition: New
£ 43.98
£ 19.68 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents contingency analysis of power system is to predict the line outage, generator outage and to keep the system secure and reliable. Whenever the maximum violation occurs in Power system, line and generator are outage… elements. For the system, security can be assessed using contingency analysis. It also describes the power flow analysis of power system network using Matpower 5.0 and estimating the real and reactive power flows, power losses in the entire network and phase angle using Matpower 5.0. This book shows the example of 5 bus test system and IEEE-14 bus power system, on which N-1 contingency sensitivity factors found out by MATLAB. N-1-1 contingency sensitivity factors are found out by Power World Simulator 11.0 by making 5-bus test system in it. For the corrective actions, FACTS devices like TCSC, FC are installed on line by finding proper location by sensitivity analysis method based on real power performance index by AC load flow. After installed FACTS device, GSF and LODF sensitivity factors are compared for TCSC and FC conditions. FC can improve sensitivity factors more than the TCSC and cheaper also than TCSC, but it has higher losses than TCSC. 124 pp. Englisch.
- More images
- Softcover
- Print on Demand
Seller: moluna, Greven, Germanymoluna
Contact seller5-star sellerCondition: New
£ 36.76
£ 41.92 shippingShips from Germany to U.S.A.Quantity: Over 20 available
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Patel NirajNiraj Patel did his Masters in Electrical Engineering (Electrical Power System) from Gujarat Technological University, Ahmedabad. He did his Bachelors in Electrical Engineering from Vishwakar…ma Government Engineering Colle.
- More images
Language: English
Published by LAP LAMBERT Academic Publishing Apr 2017, 2017
- Softcover
- Print on Demand
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germanybuchversandmimpf2000
Contact seller5-star sellerCondition: New
£ 43.98
£ 51.34 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book presents contingency analysis of power system is to predict the line outage, generator outage and to keep the system secure and reliable. Whenever the maximum violation occurs in Power system, line and generator are outage ele…ments. For the system, security can be assessed using contingency analysis. It also describes the power flow analysis of power system network using Matpower 5.0 and estimating the real and reactive power flows, power losses in the entire network and phase angle using Matpower 5.0. This book shows the example of 5 bus test system and IEEE-14 bus power system, on which N-1 contingency sensitivity factors found out by MATLAB. N-1-1 contingency sensitivity factors are found out by Power World Simulator 11.0 by making 5-bus test system in it. For the corrective actions, FACTS devices like TCSC, FC are installed on line by finding proper location by sensitivity analysis method based on real power performance index by AC load flow. After installed FACTS device, GSF and LODF sensitivity factors are compared for TCSC and FC conditions. FC can improve sensitivity factors more than the TCSC and cheaper also than TCSC, but it has higher losses than TCSC.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 124 pp. Englisch.
- More images
- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 43.98
£ 52.22 shippingShips from Germany to U.S.A.Quantity: 1 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book presents contingency analysis of power system is to predict the line outage, generator outage and to keep the system secure and reliable. Whenever the maximum violation occurs in Power system, line and generator are outage elem…ents. For the system, security can be assessed using contingency analysis. It also describes the power flow analysis of power system network using Matpower 5.0 and estimating the real and reactive power flows, power losses in the entire network and phase angle using Matpower 5.0. This book shows the example of 5 bus test system and IEEE-14 bus power system, on which N-1 contingency sensitivity factors found out by MATLAB. N-1-1 contingency sensitivity factors are found out by Power World Simulator 11.0 by making 5-bus test system in it. For the corrective actions, FACTS devices like TCSC, FC are installed on line by finding proper location by sensitivity analysis method based on real power performance index by AC load flow. After installed FACTS device, GSF and LODF sensitivity factors are compared for TCSC and FC conditions. FC can improve sensitivity factors more than the TCSC and cheaper also than TCSC, but it has higher losses than TCSC.





