The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process. The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the sensor to discriminate between polymerized and unpolymerized coatings on metal substrates down to a coating thickness of less than 16µm is demonstrated and and proved by reference measurements.
"synopsis" may belong to another edition of this title.
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # L0-9783866448391
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # L0-9783866448391
Quantity: Over 20 available
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In. Seller Inventory # ria9783866448391_new
Quantity: Over 20 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process. The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the sensor to discriminate between polymerized and unpolymerized coatings on metal substrates down to a coating thickness of less than 16µm is demonstrated and and proved by reference measurements. 146 pp. Englisch. Seller Inventory # 9783866448391
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process.The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the sensor to discriminate between polymerized and unpolymerized coatings on metal substrates down to a coating thickness of less than 16µm is demonstrated and and proved by reference measurements. 146 pp. Englisch. Seller Inventory # 9783866448391
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. Druck auf Anfrage Neuware - Printed after ordering - The work describes a method for the determination of the conversion by radical photopolymerization of acrylic coatings that is suitable for an in situ monitoring during the coating process. The applied method is based on the 1620 nm overtone absorption of the acrylate end group. The capability of the sensor to discriminate between polymerized and unpolymerized coatings on metal substrates down to a coating thickness of less than 16µm is demonstrated and and proved by reference measurements. Seller Inventory # 9783866448391
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Near Infrared Laser Sensor System for In-Line Detection of Conversion in UV-Cured Polymer Coatings | Mathias Bach | Taschenbuch | Kartoniert / Broschiert | Englisch | 2014 | Karlsruher Institut für Technologie | EAN 9783866448391 | Verantwortliche Person für die EU: Karlsruher Institut für Technologie (KIT), Institut AIFB, Kaiserstr. 89, 76133 Karlsruhe, verlag[at]aifb[dot]uni-karlsruhe[dot]de | Anbieter: preigu. Seller Inventory # 105186728