Design Implementation Low Power Device by Pires Luis (11 results)

- Softcover
Seller: BargainBookStores, Grand Rapids, MI, U.S.A.BargainBookStores
Contact seller5-star sellerCondition: New
£ 33.95
Free ShippingShips within U.S.A.Quantity: 5 available
Paperback or Softback. Condition: New. Design and Implementation of a Low-Power Device for Non-Invasive Blood Glucose. Book.

- Softcover
Seller: California Books, Miami, FL, U.S.A.California Books
Contact seller4-star sellerCondition: New
£ 34.99
Free ShippingShips within U.S.A.Quantity: Over 20 available
Condition: New.

- Softcover
Seller: PBShop.store US, Wood Dale, IL, U.S.A.PBShop.store US
Contact seller5-star sellerCondition: New
£ 46.12
Free ShippingShips within U.S.A.Quantity: Over 20 available
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000.

- Softcover
Seller: PBShop.store UK, Fairford, GLOS, United KingdomPBShop.store UK
Contact seller5-star sellerCondition: New
£ 43.23
£ 3.29 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000.

- Softcover
Seller: Revaluation Books, Exeter, United KingdomRevaluation Books
Contact seller5-star sellerCondition: New
£ 41.28
£ 10.00 shippingShips from United Kingdom to U.S.A.Quantity: 2 available
Paperback. Condition: Brand New. 44 pages. 6.00x0.10x9.00 inches. In Stock.

- Softcover
- Print on Demand
Seller: Majestic Books, Hounslow, United KingdomMajestic Books
Contact seller4-star sellerCondition: New
£ 45.64
£ 6.50 shippingShips from United Kingdom to U.S.A.Quantity: 4 available
Condition: New. Print on Demand.

- Softcover
- Print on Demand
Seller: Books Puddle, Woodside, NY, U.S.A.Books Puddle
Contact seller4-star sellerCondition: New
£ 50.34
£ 3.01 shippingShips within U.S.A.Quantity: 4 available
Condition: New. Print on Demand.

- Softcover
- Print on Demand
Seller: THE SAINT BOOKSTORE, Southport, United KingdomTHE SAINT BOOKSTORE
Contact seller5-star sellerCondition: New
£ 40.52
£ 11.52 shippingShips from United Kingdom to U.S.A.Quantity: Over 20 available
Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days.

- Softcover
- Print on Demand
Seller: Biblios, frankfurt am main, HESSE, GermanyBiblios
Contact seller4-star sellerCondition: New
£ 47.54
£ 8.56 shippingShips from Germany to U.S.A.Quantity: 4 available
Condition: New. PRINT ON DEMAND.

- Softcover
- Print on Demand
Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
Contact seller5-star sellerCondition: New
£ 45.72
£ 30.10 shippingShips from Germany to U.S.A.Quantity: 2 available
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Glucose is a simple sugar molecule. The chemical formula of this sugar molecule is C6H12O6. This means that the glucose molecule contains six carbon atoms (C), twelve hydrogen atoms (H), and six oxygen atoms (O). In human blood, the molecule glucose circulates as blood sugar. Normally, after eating or drinking, our bodies break down the sugars in food and use them to obtain energy for our cells. To execute this process, our pancreas produces insulin. Insulin 'pulls' sugar from the blood and puts it into the cells for use. If someone has diabetes, their pancreas cannot produce enough insulin. As a result, the level of glucose in their blood rises. This can lead to many potential complications, including blindness, disease, nerve damage, amputation, stroke, heart attack, damage to blood vessels, etc. In this study, a non-invasive and therefore easily usable method for monitoring blood glucose was developed. With the experiment carried out, it was possible to measure glucose levels continuously, thus eliminating the disadvantages of invasive systems. Near-IR sensors (optical sensors) were used to estimate the concentration of glucose in blood; these sensors have a wavelength of 940 nm. The sensor was placed on a small black parallelepiped-shaped box on the tip of the finger and the output of the optical sensor was then connected to a microcontroller at the analogue input. Another sensor used, but only to provide more medical information, was the heartbeat sensor, inserted into an armband (along with the microprocessor). After processing and linear regression analysis, the glucose level was predicted, and data were sent via the Bluetooth network to a developed APP. The results of the implemented device were compared with available invasive methods (commercial products). The hardware consisted of a microcontroller, a near-IR optical sensor, a heartbeat sensor, and a Bluetooth module. Another objective of this experiment using low-cost and low-power hardware was to not carry out complex processing of data from the sensors.…

- Softcover
- Print on Demand
Seller: preigu, Osnabrück, Germanypreigu
Contact seller5-star sellerCondition: New
£ 38.54
£ 60.20 shippingShips from Germany to U.S.A.Quantity: 5 available
Taschenbuch. Condition: Neu. Design and Implementation of a Low-Power Device for Non-Invasive Blood Glucose | Luis Pires | Taschenbuch | Englisch | 2024 | Eliva Press | EAN 9781636486819 | Verantwortliche Person für die EU: Libri GmbH, Europaallee 1, 36244 Bad Hersfeld, gpsr[at]libri[dot]de | Anbieter: preigu Print on Demand.…