The book provides useful background information and reference materials to help explain the different approaches and interventions that are used to reduce water losses. Numerous real case studies are provided that highlight the processes and methodologies employed around the world to reduce water losses. Water Management and Water Loss covers many aspects of water loss control including, pressure management, leak detection and repair, Internal plumbing losses and retrofitting, community involvement and education/awareness, schools education and leak repair projects.
Authors: Stuart Hamilton, Hydrotec Ltd.,Thorpe Underwood, Northants, UK and Ronnie McKenzie, Groenkloof, Pretoria, South Africa
"Synopsis" may belong to another edition of this title.
Excerpt. © Reprinted by permission. All rights reserved.
Water Management and Water Loss
By Stuart Hamilton, Ronnie McKenzieIWA Publishing
All rights reserved.
Contents
Chapter 1 Introduction, 1,
Chapter 2 Leak detection technologies, 5,
Chapter 3 Principles of pressure management, 19,
Chapter 4 The repair or replace dilemma Jo Parker, 51,
Chapter 5 Community awareness and education, 69,
Chapter 6 Meter logging and recording, 87,
Chapter 7 Large consumer meter consolidation and improvements: Planning, implementation and benefits, 109,
Chapter 8 Software tools to assist with water loss reduction in municipal systems, 121,
Chapter 9 International case studies from around the world, 143,
Chapter 9.1 Application in water loss reduction project in Bosnia and Herzegovina Ðevad Koldzo and Branko Vucijak, 144,
Chapter 9.2 Large scale water loss management improvement programme in Zagreb (Croatia) water distribution network Kristijan Ilicic, Jurica Kovac, Vlado Herceg, Berislav Bohatka, Mario Medven and Ivan Grdenic, 151,
Chapter 9.3 Analysis of the water losses from the aspect of central water meters in objects of collective housing Bajci Angela and Radovanov Milenko, 160,
Chapter 9.4 Water loss management in Novi Sad water utility, Serbia Zlatko Arvaji and Ikonija Karadzic, 170,
Chapter 9.5 Continuous acoustic monitoring – evolution of an innovation in the USA David Hughes, 176,
Chapter 9.6 Establishing the first validated dataset of North American water utility water audit data A. Chastain-Howley, G. Kunkel and W. Jernigan, 182,
CHAPTER 1
Introduction
Water losses from municipal reticulation systems are becoming a serious problem throughout the world and particularly in developing countries where lack of funds often results in poor maintenance of the water infrastructure. In some areas, the water losses are now estimated to be higher than the actual legitimate water use and the situation is gradually deteriorating to such an extent that intermittent supply is now the norm rather than the exception in some parts of the world.
The International Water Association has identified water loss from municipal systems as one of the most important issues facing a world where the ever increasing population is placing additional strain on systems which are already failing to meet the current demands. In response to these problems, the Water Losses Specialist Group was formed and has emerged as one of the most active and significant groups within the IWA. Its key function is to share the knowledge from specialists throughout the world to assist water suppliers to manage and reduce their water losses. Through the efforts of the group, many new and innovative techniques have been developed to measure, monitor and analyse water losses from municipal water supply systems. A standard water balance has been developed which is now widely accepted worldwide and enables water suppliers to quantify the magnitude of their water losses in a standard and pragmatic approach after which they can select the most appropriate interventions for a specific area. No "one-size fits all" solution is appropriate when trying to deal with water losses and it is important to understand that each area has its own set of problems, some of which may be common to other areas and some of which may be unique to a specific region. It is therefore necessary to identify the key problems and to implement the appropriate interventions.
This book provides a basic overview of the key issues frequently experienced by water supply managers in both developing and developed countries. It is designed to assist water supply managers to understand the problems experienced in their own systems and provides advice on how the problems can be addressed through examples and practical case studies. The book is non-academic and is aimed at providing information and advice in a practical and easy to understand manner. The book is basically a collection of case studies and practical experience from numerous water loss specialists who have worked around the world and have experienced both 'best practice' and the opposite extreme. It is hoped that by providing such examples and case studies, water supply managers and those employed to assist them, can benefit from both the successes and failures discussed in the book.
1.1 THE TECHNOLOGY MATRICES
The choice of a particular leak detection/location technique and technology depends on the operating conditions and construction material of the pipeline in question. To assist in making this determination, four different matrices have been developed.
(1) Mains fittings only – high pressure
• For leakage detection on mains fittings only (no house connections) with pressures greater than 10 m head or 15 psi. Fittings are at a minimum distance of 200 m apart and maximum 500 m
(2) Mains fittings only – low pressure
• For leakage detection on mains fittings only (no house connections) with pressures less than 10 m head or 15 psi. Fittings are at a minimum distance of 200 m apart and maximum 500 m
(3) Domestic and mains fittings – high pressure
• For leakage detection on all property and mains fittings with pressures greater than 10 m head or 15 psi. Fittings are at a minimum distance of 10 m apart and maximum 50 m
(4) Domestic and mains fittings – low pressure
• For leakage detection on all property and mains fittings with pressures less than 10 m head or 15 psi. Fittings are at a minimum distance of 10 m apart and maximum 50 m
The matrices consider the following pipeline materials:
• Metallic
* Includes steel, ductile iron and other ferrous materials
• Concrete
* Includes reinforced concrete, pre-stressed concrete pipe (PCP)
• Asbestos cement
• Glass-reinforced plastic (GRP)
• Polyvinyl chloride (PVC)
• Polyethylene
* MDPE medium density poly ethylene
* HDPE high density poly ethylene
The technologies available are discussed in more detail later in this document. The equipment has been placed in the selected categories where it is reliably successful. The equipment may sometimes be successful in other categories but not reliably so.
Note that new equipment is continuously being developed: these matrices only take into account equipment that was available during the preparation of the matrices (up to December 2012).
1.1.1 Main pipelines only – high pressure
This matrix is for leakage detection on mains fittings only (no house connections) with pressures greater than 10 m head or 15 psi. Fittings are at a minimum distance of 200 m apart and maximum 500 m.
1.1.2 Main pipelines only – low pressure
This matrix is for leakage detection on mains fittings only (no house connections) with pressures less than 10 m head or 15 psi. Fittings are at a minimum distance of 200 m apart and maximum 500 m.
1.1.3 Domestic and mains fittings – high pressure
This matrix is for leakage detection on all property and mains fittings with pressures greater than 10 m head or 15 psi. Fittings are at a minimum distance of 10 m apart and maximum 50 m.
1.1.4 Domestic and mains fittings – low pressure
This matrix is for leakage detection on all property and mains fittings with pressures less than 10 m head or 15 psi. Fittings are at a minimum distance of 10 m apart and maximum 50 m.
CHAPTER 2Leak detection technologies
There are a vast number of techniques to detect where leakage is occurring in the network. Location accuracy depends on many factors, and the subsequent portions of this document provide further detail. Some techniques are able to approximate or localize the position of a leak while others can find exact locations. Often a tool-box approach is used, where multiple technologies are deployed.
2.1 METHOD A: GAS INJECTION METHOD
This method uses a gas detector to find the presence of a tracer gas that has been injected into a pipeline. While helium can be used, the most common tracer gas is hydrogen due to its lower cost and high performance.
Hydrogen is the lightest gas and has the lowest viscosity. This makes it easy to fill, evacuate and dissipate. Typically diluted 5% in nitrogen, the gas can be injected into buried and ducted cables, pipelines and also small diameter in-house heating pipes.
The gas injection method can be used to detect leaks in all pipe materials from 75 mm to 1000 mm in diameter. It can be used on pipes of greater diameter but for obvious reasons a considerable amount of gas would be required. The pipeline can be empty of water or full, however with the pipeline full of water, less gas is required to be used to find the leak.
To accurately locate the leaking gas which comes to the surface after leaving the leak in the pipe, the direction of the water flow must be known and the gas should be kept within the pipeline in which the leak is suspected. This requires the closure of any branches/off-takes which may cause the gas to be diluted or transferred away from the pipeline in question. The mixing of the gas with water does not affect the water quality. This methodology can be used in all types of sealed tubes including cables and pipelines. The material has no effect on the gas injected.
2.2 METHOD B: MANUAL LISTENING STICK
The stethoscope or listening stick has an earpiece and is used to listen to leaks in fittings and to pinpoint the location of a leak. It is a widely used piece of equipment for many water utilities. The material of the listening stick can be metal, wooden or plastic. This technique is dependent on the ability of the engineer to hear the leak and uses no electronic equipment to enhance the sound.
This technique is best suited for use on metallic pipelines between 75 mm and 250 mm and with pressures above 10 m (15 psi). The material or pipe size does not prevent the listening stick from being able to pinpoint the leak from the surface, but what does affect this is the type of leak, ground backfill material, pressure of the water leaving the pipe, background noise and the ability of the engineer (Figure 2.1).
2.3 METHODS C AND D: LEAK NOISE CORRELATION
Leak noise correlation works by comparing the noise detected at two different points in the pipeline. Assuming consistent pipe material and diameter, the noise travels from the leak in both directions at a constant velocity, so that if the leak is equidistant between two sensors then these sensors will detect the noise at the same time. Conversely, if the leak is not equidistant, then the sensors will detect the same noise at different times – this difference in arrival times is measured by the correlation process.
The following diagram illustrates this principle (Figure 2.2):
The sensors are located on valves A and B (convenient access points for underground pipes), and as shown, the leak position is closer to A.
By the time an instance of noise from the leak has reached A, the same noise heading towards B has only travelled as far as point X. The distance from X to B causes a time delay (t) before the noise arrives at B. The correlation processing detects the delay (t) between the arrival of the noise at A and its arrival at B. If the velocity of sound is V and the distance between the loggers is D, then as the distance from X to B = V * t.
Then D = (2 * L) + (V* t).
This equation may be rearranged to give L, the distance from the nearer logger to the leak site:
L = D - (V * t)/2
Correlation measures the time delay (t). The distance between the sensors must be determined by accurate measurement.
The sound velocity depends upon pipe material, pipe diameter and, to a lesser extent, on surrounding soil. Often, theoretical values of sound velocity are used and this is fine for a first approximation of the leak position. However, the velocity will vary due to many factors, and significantly so if a repair section of a different pipe material exists. Sound velocity must therefore be measured or, alternatively, multiple correlations carried out.
With all correlation techniques, practitioners should be aware that any noise source can result in a correlation peak and all results should thus be treated as 'points of interest' until confirmed. Confirmation is usually done using a ground microphone.
It is important to note that the capability of correlators is dependent on the pressure and level of background noise within the network. Furthermore, correlation can become impossible, because it requires two monitoring points, one on each side of the leak and the attenuation often causes leak signals to disappear at one or both points.
Leak noise correlation requires a noise signal. There are two types of noise transducer in normal use: accelerometers and hydrophones. These have significant differences in their deployment and uses, and have hence been identified as two different methods in the sections below.
2.4 METHOD C: CORRELATION USING ACCELEROMETERS
To perform correlation using accelerometers, two sensors are deployed on pipe fittings, so no access to the water inside the pipe is required. The sensors are then positioned on either side of the suspect leak position. Accelerometers respond to acceleration and so tend to be more responsive to higher frequencies
Accelerometers are most effective on metallic pipes and tend to be less effective with non-metallic pipes. This is due to both the rapid attenuation of high frequency signals in many non-metallic pipes and the impedance mismatch between the pipe material and the metal fittings normally used to site accelerometers. However their ease of deployment and low-cost make them an attractive choice when trying to localize leaks (Figure 2.3).
2.5 METHOD D: CORRELATION USING HYDROPHONES
Leak location on plastic pipes and in large diameter pipes is difficult because they become more elastic as the pipe material gets softer, or the ratio of pipe wall thickness to overall diameter increases. This results in more rapid absorption of leak energy into the pipe material and surrounding soil, with resultant attenuation as distance from the leak increases.
Furthermore, higher frequency leak noise energy is absorbed much more rapidly than low frequency energy.
Accelerometers placed on the outside of the pipe detect the energy lost into the pipe wall. The water-borne wave is detected directly by hydrophones placed into the water at convenient fittings such as fire hydrants. Combined with advanced filtering technology, particularly at very low acoustic frequencies, hydrophones are beneficial in enabling leak location on plastic pipes and on larger diameter mains (Figure 2.4).
Hydrophone-based acoustic correlation techniques are beneficial in locating leaks in difficult situations. These situations are likely to occur in the following:
• Large diameter or trunk mains
• Plastic pipes
• Pipes with large distances between available pipe access points
• When high acoustic background noise exists, often due to traffic, and so on.
2.6 METHOD E: IN-LINE LEAK DETECTION TECHNIQUES
Specifically designed for large diameter pipes, in-line systems are able to discriminate between multiple leaks in a single length of pipeline. Pipelines can be inspected while under pressure and in service, and leaks are accurately located. Equipment is suitable for potable water applications, and no disruption to customers is needed.
There are two types of in-line systems; tethered and free swimming. Both have their advantages and disadvantages, but in both cases a sensor passes directly beside leaks, meaning that neither the pipe material nor the type of leak is relevant. The proximity of the sensor to any leak also results in very sensitive systems and the detection of small leaks.
2.6.1 Tethered systems
Tethered systems operate by deploying a hydrophone into the pipeline to be inspected. The hydrophone is connected to a signal processing and display unit via an umbilical cable. The sensor travels along inside the pipe pulled by the flow of water acting on a drogue (parachute) attached to the front of the sensor. As the sensor passes any leak in the pipeline it will detect the noise being generated by the water escaping through the leak. At this point the operator is able to stop deployment of the sensor (by stopping deployment of the umbilical) and then position the sensor at the leak position by withdrawing or deploying the umbilical as necessary.
Once the sensor is sited at the leak, the position of the sensor can be determined using a locating system mounted in the sensor head. A second operator can track the position of the sensor head during deployment using this locating device giving an accurate indication of the sensor location and pipe track. Having pinpointed the position of the sensor, the exact location of any leak can be marked on the ground over the pipe (Figure 2.5).
Tethered systems are best suited to work in relatively straight pipelines where deployments of up to 2 km from a single insertion point are possible; other constraints may restrict the length that can be surveyed from each insertion point. Careful planning of the work will maximize the distance that can be surveyed.
Tethered systems are deployed through a tapping made into the pipe. Typically these insertion points may be air-valve connections, insertion flowmeter tappings or specially installed points.
Tethered systems that can access the main through fire hydrants are also available. Alternative sensors, including video and ultrasonic pipe-wall inspection, are also available (Figure 2.6).
2.6.2 Free swimming systems
Free-swimming data acquisition systems for detecting leaks in fluid pipelines are also available. These systems are inserted into a live pipeline and pushed along the pipeline by the water flow. At the end of the inspection, a net or similar capture device is used to catch and extract the system from the pipeline or they are discharged into an open catchment area such as a reservoir and recovered from there; an acoustic recording is made during the entire inspection.
(Continues...)
Excerpted from Water Management and Water Loss by Stuart Hamilton, Ronnie McKenzie. Copyright © 2014 IWA Publishing. Excerpted by permission of IWA Publishing.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.
"About the title" may belong to another edition of this title.
Revaluation Books
Exeter, United Kingdom
AbeBooks seller since January 6, 2003
Shipping rates from United Kingdom to U.S.A.
| Item | 7 to 14 business days | 2 to 3 business days |
|---|---|---|
| First item | £ 10.00 | £ 25.00 |
Payment methods
Seller's business information
Edward Bowditch Ltd
Exstowe, Exton
Exeter, United Kingdom EX3 0PP
Terms of sale
Legal entity name: Edward Bowditch Ltd
Legal entity form: Limited company
Business correspondence address: Exstowe, Exton, Exeter, EX3 0PP
Company registration number: 04916632
VAT registration: GB834241546
Authorised representative: Mr. E. Bowditch
Right of withdrawal
If you are a consumer you can withdraw from the contract in accordance with the following. Consumer means any natural person who is acting for purposes which are outside his trade, business, craft or profession.
Information regarding the right of withdrawal
Statutory right to withdraw
You have the right to withdraw from this contract within 14 days without giving any reason.
The withdrawal period will expire after 14 days from the day on which you acquire, or a third party other than the carrier and indicated by you acquires, physical possession of the last good or the last lot or piece.
To exercise the right of withdrawal, electronically fill in and submit a clear statement on our website, under "My Purchases" in "My Account". We will communicate to you an acknowledgement of receipt of such a withdrawal on a durable medium (e.g. by e-mail) without delay.
To meet the withdrawal deadline, it is sufficient for you to send your communication concerning your exercise of the right of withdrawal before the withdrawal period has expired.
Effects of withdrawal
If you withdraw from this contract, we will reimburse to you all payments received from you, including the costs of delivery (except for the supplementary costs arising if you chose a type of delivery other than the least expensive type of standard delivery offered by us).
We may make a deduction from the reimbursement for loss in value of any goods supplied, if the loss is the result of unnecessary handling by you.
We will make the reimbursement without undue delay, and not later than 14 days after the day on which we are informed about your decision to withdraw from this contract.
We will make the reimbursement using the same means of payment as you used for the initial transaction, unless you have expressly agreed otherwise; in any event, you will not incur any fees as a result of such reimbursement.
We may withhold reimbursement until we have received the goods back, or you have supplied evidence of having sent back the goods, whichever is the earliest.
You shall send back the goods or hand them over to Revaluation Books, Hounslow, United Kingdom, without undue delay and in any event not later than 14 days from the day on which you communicate your withdrawal from this contract to us. The deadline is met if you send back the goods before the period of 14 days has expired. You will have to bear the direct cost of returning the goods. You are only liable for any diminished value of the goods resulting from the handling other than what is necessary to establish the nature, characteristics and functioning of the goods.
Exceptions to the right of withdrawal
The right of withdrawal does not apply to:
- The delivery of newspapers, journals or magazines with the exception of subscription contracts; and
- The supply of digital content which is not supplied on a tangible medium (e.g. on a CD or DVD) if you accepted when you placed your order that we could start to deliver it, and that you could not withdraw once delivery had started.
Shipping terms
Orders usually dispatched within two working days.