Substation Faults and Protection

Language: English

Published by GRIN Verlag, 2013

3656412332 / 9783656412335

  • Softcover
  • New
See all details

Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

5-star seller

AbeBooks seller since August 14, 2006

Softcover

Condition: New

£ 15.42

£ 29.20 shipping 
Ships from Germany to U.S.A.

Quantity: 1 available

Add to basket
Free 30-day returns

Item description from seller

Druck auf Anfrage Neuware - Printed after ordering - Technical Report from the year 2011 in the subject Engineering - Power Engineering, grade: A, ( Atlantic International University ) (Niger Delta University), course: SFP 673, language: English, abstract: The purpose of this work is to establish the type of faults that may result when substations are sited in the region of the Niger Delta due to the prevailing climatic conditions. This will aimed at ensuring as far as possible a small probability of damage to substation insulations.For most transmission lines, relatively large numbers of yearly flashovers are permitted but such number of insulation damages is absolutely not allowed for substations. Flashover of insulation at substation means a short circuit on the busbar which even with the modern means of relay protection can cause most sever system damages. Substations unlike lines have very low probability of damage therefore a quantitative idea of the probability, the so called index of lightning resistance of a substation is used. It is equal to the calculated number of years during which a voltage dangerous for the substation installation does not occur. For modern high voltage substations, the index of lightning resistance is calculated as hundred or even as thousand years which is a proof of attempts made by designers to ensure the largest degree of lightning resistance of substation (Rao,2008,U.S Dept of Agri.2001,Martinez and Castro 2003).Substations must be protected from the direct lightning strokes and voltage waves travelling from the line as well as switching surges. In transmission lines the induced strokes (indirect strokes) due to lightning are important for 11kv lines only. For high voltage transmission lines (up to 220kv) the surges due direct lightning strokes determine the line insulations design. For extra high voltage (400kv and above) the severity of swiching surges is much more than that due to lightning (Gupta, 2008). Whether external or internal over voltage, for reliable operations of substation proper protection is necessary. There are factors that may not produce over voltage but are capable of affecting the operation of the equipments as well as lowering the flashover, these are humidity, rain temperature, pressure and to some extent contamination on the surface of insulator and equipments (outdoor).For proper consideration of these factors with the external and internal over voltages, a proper selection of protective devices may be made for the safe operation of substation.…

Title
Substation Faults and Protection
Author
John Tarilanyo Afa
Publisher
GRIN Verlag
Publication year
2013
Condition
Neu
Binding
Taschenbuch
Language
English
ISBN 10
3656412332
ISBN 13
9783656412335
Item weight
51 grams
Dimensions
210x148x3 mm

AHA-BUCH GmbH

Einbeck, Germany

5-star seller

AbeBooks seller since August 14, 2006

Shipping rates from Germany to U.S.A.

Item7 to 10 business days5 to 7 business days
First item£ 29.20£ 37.54
Delivery times are set by sellers and vary by carrier and location. Orders passing through Customs may face delays and buyers are responsible for any associated duties or fees. Sellers may contact you regarding additional charges to cover any increased costs to ship your items.

Payment methods

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Bank Wire Transfer
  • Check
  • Paypal

Store description

Das Unternehmen AHA-BUCH GmbH: Seit der Gründung von AHA-BUCH im Juli 2005 ist unser Hauptziel, zufriedenen Kunden so schnell und so preisgünstig wie möglich ihren Bücherwunsch zu erfüllen. Unsere Firma beschäftigt 16 Mitarbeiter, die nur ein Ziel kennen: den Kunden und seine Wünsche! Auf über 3700 m2 Fläche haben wir über 100.000 Bücher, Modernes Antiquariat und Spiele auf Lager.

Specialty

Kinderbücher & Kinderhör Casetten, German Books, Software, Natur & Tiere, Ratgeber, Sachbücher, Englische Bücher, Medizin & Gesundheit, Universität & Studium

Seller's business information

AHA-BUCH GmbH

Garlebsen 48
Einbeck, Germany 37574

Imprint

Seller Info:

AHA-BUCH GmbH
represented by the managing director Christel Glass
Garlebsen 48
37574 Einbeck
Deutschland
Telefon: 055639996039
Telefax: 055639995974
E-Mail: abebooks@aha-buch.de
USt-IdNr.: DE261904229
registered at Commercial register Amtsgerichtes Göttingen
Handelsregisternummer HRB 200691

Alternative dispute resolution:
The European Commission provides a platform for out-of-court online dispute resolution (ODR platform), which can be accessed under https://ec.europa.eu/odr.

We have been a member of the "FairCommerce" initiative since 25.05.2018.
For more information, see www.fair-commerce.de.