Refrigerant Charging and Service Procedures Handbook for Air Conditioning (Paperback)
Language: English
Published by Independently Published, 2026
- Softcover
- New

Seller: CitiRetail, Stevenage, United KingdomCitiRetail
AbeBooks seller since June 29, 2022
Condition: New
£ 73.49
Quantity: 1 available
Add to basketItem description from seller
Paperback. A technician standing at a condensing unit with a set of gauges is making decisions that determine system performance, energy cost, and legal compliance, often within a single service call.Too many of those calls still run on a single gauge reading and a guess. High superheat gets refrigerant added. Low subcooling gets refrigerant added. A restricted filter-drier, a dirty condenser coil, and a failing metering device can all produce the same misleading numbers, and refrigerant keeps getting added until the real fault catches up with the compressor, or with the paperwork required under current federal recovery and recordkeeping rules.This handbook was built as a single procedures-focused reference that follows the logical sequence of a real service call, from first inspection to final documentation, connecting the vapor-compression cycle to the decisions a technician actually makes: choosing the correct charging method for the installed metering device, evacuating and dehydrating to a verified vacuum, confirming a leak before reaching for the recovery machine, and diagnosing charge- and airflow-related faults instead of defaulting to adding refrigerant. Each of its thirteen chapters opens with clear learning objectives, works through complete examples with units carried at every step, and closes with practice problems and provided answers.Inside, you will be able to: Understand the vapor-compression cycle well enough to explain why a superheat or subcooling reading is behaving the way it is, not just what to do when it doesApply weight-based, superheat, and subcooling charging methods correctly, matched to the installed metering device, using worked calculations that carry units at every stepEvacuate and dehydrate a system to a verified micron level and recognize a decay test that points to a leak rather than residual moistureDetect, confirm, and repair leaks, and select recovery and tool practices appropriate to the refrigerant classification involved, including the workspace considerations that apply to mildly flammable refrigerant categoriesWork through a structured diagnostic sequence for charge-related, airflow-related, electrical, and mechanical faultsMeet current federal recordkeeping, evacuation-level, and recovery and reclamation documentation requirements as a built-in part of the service process, not a separate compliance moduleThe book follows the complete arc of a service call across thirteen chapters: refrigeration fundamentals and the pressure-enthalpy relationship; refrigerant properties and regulatory classification, including mildly flammable categories; core federal compliance obligations; tools, instruments, calibration, and safe work practice; system inspection; evacuation and dehydration; refrigerant recovery; charging by weight, superheat, and subcooling; leak detection technologies; leak repair and pressure verification; charge- and airflow-related fault diagnosis; electrical and mechanical component diagnostics; and refrigerant recovery, reclamation, and environmental compliance across a refrigerant's full service life, supported by a glossary and four reference appendices, including a pressure-temperature chart and unit conversion tables.This handbook is written for practicing HVAC technicians, field engineers supporting service operations, and advanced trainees who already hold, or are working toward, federal refrigerant-handling certification. Readers are assumed to have some prior exposure to basic electrical and mechanical concepts; this is a procedures-focused reference rather than a general survey of heating and cooling theory, and it is equally suited to a working reference shelf or a training-program reading list.Take the next step toward diagnosing with evidence instead of habit. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability.…
Seller Inventory # 9798174661219
- Title
- Refrigerant Charging and Service Procedures Handbook for Air Conditioning (Paperback)
- Author
- Keller Ben
- Publisher
- Independently Published
- Publication year
- 2026
- Condition
- new
- Binding
- Paperback
- Language
- English
- ISBN 13
- 9798174661219
- Series
- Book 1 of 2: The HVAC-R Technician's Field Library
Too many of those calls still run on a single gauge reading and a guess. High superheat gets refrigerant added. Low subcooling gets refrigerant added. A restricted filter-drier, a dirty condenser coil, and a failing metering device can all produce the same misleading numbers, and refrigerant keeps getting added until the real fault catches up with the compressor, or with the paperwork required under current federal recovery and recordkeeping rules.
This handbook was built as a single procedures-focused reference that follows the logical sequence of a real service call, from first inspection to final documentation, connecting the vapor-compression cycle to the decisions a technician actually makes: choosing the correct charging method for the installed metering device, evacuating and dehydrating to a verified vacuum, confirming a leak before reaching for the recovery machine, and diagnosing charge- and airflow-related faults instead of defaulting to adding refrigerant. Each of its thirteen chapters opens with clear learning objectives, works through complete examples with units carried at every step, and closes with practice problems and provided answers.
Inside, you will be able to:
- Understand the vapor-compression cycle well enough to explain why a superheat or subcooling reading is behaving the way it is, not just what to do when it does
- Apply weight-based, superheat, and subcooling charging methods correctly, matched to the installed metering device, using worked calculations that carry units at every step
- Evacuate and dehydrate a system to a verified micron level and recognize a decay test that points to a leak rather than residual moisture
- Detect, confirm, and repair leaks, and select recovery and tool practices appropriate to the refrigerant classification involved, including the workspace considerations that apply to mildly flammable refrigerant categories
- Work through a structured diagnostic sequence for charge-related, airflow-related, electrical, and mechanical faults
- Meet current federal recordkeeping, evacuation-level, and recovery and reclamation documentation requirements as a built-in part of the service process, not a separate compliance module
This handbook is written for practicing HVAC technicians, field engineers supporting service operations, and advanced trainees who already hold, or are working toward, federal refrigerant-handling certification. Readers are assumed to have some prior exposure to basic electrical and mechanical concepts; this is a procedures-focused reference rather than a general survey of heating and cooling theory, and it is equally suited to a working reference shelf or a training-program reading list.
Take the next step toward diagnosing with evidence instead of habit. Get your copy and start building a reference you can return to on every service call
"Synopsis" may belong to another edition of this title.
CitiRetail
Stevenage, United Kingdom
AbeBooks seller since June 29, 2022
Shipping rates from United Kingdom to U.S.A.
| Item | 7 to 14 business days | 7 to 60 business days |
|---|---|---|
| First item | £ 37.00 | £ 37.00 |
Payment methods
Store description
Online business
Seller's business information
ABC BOOKS LIMITED
10 John Street
London, United Kingdom WC1N 2EB
Terms of sale
Orders can be returned within 30 days of receipt.
Right of withdrawal
If you are a consumer you can withdraw from the contract in accordance with the following. Consumer means any natural person who is acting for purposes which are outside his trade, business, craft or profession.
Information regarding the right of withdrawal
Statutory right to withdraw
You have the right to withdraw from this contract within 14 days without giving any reason.
The withdrawal period will expire after 14 days from the day on which you acquire, or a third party other than the carrier and indicated by you acquires, physical possession of the last good or the last lot or piece.
To exercise the right of withdrawal, electronically fill in and submit a clear statement on our website, under "My Purchases" in "My Account". We will communicate to you an acknowledgement of receipt of such a withdrawal on a durable medium (e.g. by e-mail) without delay.
To meet the withdrawal deadline, it is sufficient for you to send your communication concerning your exercise of the right of withdrawal before the withdrawal period has expired.
Effects of withdrawal
If you withdraw from this contract, we will reimburse to you all payments received from you, including the costs of delivery (except for the supplementary costs arising if you chose a type of delivery other than the least expensive type of standard delivery offered by us).
We may make a deduction from the reimbursement for loss in value of any goods supplied, if the loss is the result of unnecessary handling by you.
We will make the reimbursement without undue delay, and not later than 14 days after the day on which we are informed about your decision to withdraw from this contract.
We will make the reimbursement using the same means of payment as you used for the initial transaction, unless you have expressly agreed otherwise; in any event, you will not incur any fees as a result of such reimbursement.
We may withhold reimbursement until we have received the goods back, or you have supplied evidence of having sent back the goods, whichever is the earliest.
You shall send back the goods or hand them over to CitiRetail, Stevenage, United Kingdom, without undue delay and in any event not later than 14 days from the day on which you communicate your withdrawal from this contract to us. The deadline is met if you send back the goods before the period of 14 days has expired. You will have to bear the direct cost of returning the goods. You are only liable for any diminished value of the goods resulting from the handling other than what is necessary to establish the nature, characteristics and functioning of the goods.
Exceptions to the right of withdrawal
The right of withdrawal does not apply to:
- The delivery of newspapers, journals or magazines with the exception of subscription contracts; and
- The supply of digital content which is not supplied on a tangible medium (e.g. on a CD or DVD) if you accepted when you placed your order that we could start to deliver it, and that you could not withdraw once delivery had started.
Shipping terms
Please note that titles are dispatched from our US, Canadian or Australian warehouses. Delivery times specified in shipping terms. Orders ship within 2 business days. Delivery to your door then takes 7-14 days.