Optimization of Paced AV Delay Using Atrial Contribution Index. This item is unavailable.

Language: English

Published by Nova Science Publishers Inc Okt 2008, 2008

1604566043 / 9781604566048

  • Softcover
  • New
See all details

Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH

5-star seller

AbeBooks seller since August 14, 2006

Unavailable
Softcover

Condition: New

£ 71.33

This specific item is no longer available.

Item description from seller

Neuware - The hemodynamic effect of the atria on the net performance of the heart is called atrial contribution (AC). AC is either linked to ventricular filling or to the systolic function of the heart, i.e. to the systolic volume or cardiac output. Several noninvasive methods for the quantification of AC are described in literature but none of them are routinely used in cardiac pacing centres due to the time-consuming nature of the methods, the limited reproducibility of measured values and observer dependency. The aim of these studies was to develop a method for determining optimal AV delay in patients treated by dual chamber pacing using an index (ACSp) that quantifies atrial contribution to the systolic volume of the left ventricle. The new method is based on the quantitative analysis of a beat to beat decrease in the amplitude of the pulse oximetry signal (SpO2). The change in the amplitudes is induced by a sudden drop of the stimulus to the right atrium, while maintaining the rate of ventricular stimuli at a constant level. The obtained ACSp is given as a percentage of the pulse amplitude of SpO2. The method is independent of the observer, non-invasive and relatively fast. In a group of 47 patients, remarkable similarities between ACSp and another atrial contribution index estimated using the tracings of invasively registered aortal pressure were demonstrated. In all investigated AV intervals of 50 to 250 ms, significant inter-individual variability of ACSp was discovered. The poorest hemodynamic effect was seen at AV delay of 50 ms (median ACSp of 10.4 % from 97 subjects). In 150 subjects, the following values of ACSp were obtained at AV delay of 200 ms: median 30 %, minimum 3.6 % and maximum 80.4 %. An increase in ACSp follows reduction of preload induced by administration of furosemide. This suggests that when preload decreases cardiac output is preserved by an increase in AC enforced by sympathetic activation.…

Seller Inventory # 9781604566048

Title
Optimization of Paced AV Delay Using Atrial Contribution Index
Author
Miroslav Mestan
Publisher
Nova Science Publishers Inc Okt 2008
Publication year
2008
Condition
Neu
Binding
Taschenbuch
Language
English
ISBN 10
1604566043
ISBN 13
9781604566048
Item weight
148 grams
Dimensions
216x139x1 mm

Search results for Optimization of Paced AV Delay Using Atrial Contribution Index