Novel Method for Measuring the Time of Death on Teeth - Based on Liquid Contents, Reflection Spectra and Colour
Language: English
Published by Hoffmann, 2004
- Softcover
- New

Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, GermanyBuchWeltWeit Ludwig Meier e.K.
AbeBooks seller since January 11, 2012
Condition: New
£ 35.31
Quantity: 2 available
Add to basketItem description from seller
This item is printed on demand - it takes 3-4 days longer - Neuware -Knowing about the time of death is often the central key to solving criminal cases. The time of death is also relevant in cases of natural death - for the family register entry, for the insurance system or the succession. However, the forensic medical estimation of the time of death (postmortal interval) is still not without limitations - especially if it should be precise or if it cannot be done relatively immediately after onset of death. With the onset of death, various processes begin to set in place that change a corpse and its tissues over the time axis.If it were possible to find a process in a certain tissue that would behave precisely like one or, better, several clockworks, and if it were still possible to reset the time to the state before or at the time of death, if it would also be possible that these synchronous clocks run again, and if it were also possible to run the elapsed time after death in real time on the identical individual to be examined or the identical examination object under comparable conditions (simulation), the perfect and most precise method for determining the time of death would be born.The author of the present work has observed that teeth of dead appear much brighter, differently coloured and less translucent and more opaque than teeth of living people and that dental colour changes are based on reversible drying and liquid absorption processes and can be measured with high precision and very differentiated values - he revealed phenomena, paradoxes, dynamics and liquid flow and articulates the 'dental fingerprint' for identification, 'tooth clock', 'tooth memory' .He measures the loss of liquid in ranges of up to one millionth of a gram, in the microgram range, as well as the colour and reflection spectra with high-precision measuring systems and he sees a fundamental possibility in the use of processes that he has measured and analyzed on drying and liquid-absorbing teeth and he is presenting a novel method for the first time. Furthermore, for the first time, he also presents a reference-independent approach (perhaps the first reference-independent analysis or measurement method in the natural sciences) based on drying up to the time of the first measurement, liquid storage and repeated drying - the actual simulation. For this reference-independent method approach, in contrast to his reference-dependent method, it does not necessarily need reference values, i.e. values that had to be obtained beforehand on other, comparable samples (see nomogram), but only values that were obtained previously on the identical object. For the first time, the 'scattering problem' was circumvented - the way to a high-precision method The novel method of analyzing and measuring the time of death seems to have a number of advantages: objectifying measurement instead of subjective estimations of stages; several independent values, such as L \*, a \*, b \*, C \*, h, M, spectral values, instead of just one numerical value (temperature in degrees) in the case of the body cooling method, reversibility instead of irreversibility of the processes and thus, after sufficient liquid storage, repeatability of the post-mortem conditions and consequently the post-mortem interval up to the first measurement in the context of a simulation under comparable conditions on the identical object and thus avoidance of the 'scattering problem', avoidance of intra- and inter-individual differences on both sides of the autopsy table - for the estimating and for the estimated individual, time of death measurement on site or high-precision measurements with high-precision positioning systems instead of measurement with thermometers, in the author's vision, comfortable measurements of various samples independently of one another within an automatic analyzer simulating ambient conditions in the laboratory instead . - A breakthrough 96 pp. Englisch.…
Seller Inventory # 9783340000374
- Title
- Novel Method for Measuring the Time of Death on Teeth - Based on Liquid Contents, Reflection Spectra and Colour
- Author
- André Hoffmann
- Publisher
- Hoffmann
- Publication year
- 2004
- Condition
- Neu
- Binding
- Taschenbuch
- Language
- English
- ISBN 10
- 3340000379
- ISBN 13
- 9783340000374
- Item weight
- 119 grams
- Dimensions
- 210x148x6 mm
"Synopsis" may belong to another edition of this title.
BuchWeltWeit Ludwig Meier e.K.
Bergisch Gladbach, Germany
AbeBooks seller since January 11, 2012
Shipping rates from Germany to U.S.A.
| Item | 5 to 15 business days | 5 to 15 business days |
|---|---|---|
| First item | £ 19.71 | £ 19.71 |
Payment methods
- Bank Wire Transfer
- Check
- Paypal
Seller's business information
BuchWeltWeit Ludwig Meier e.K.
Germany
Terms of sale
BuchWeltWeit Inh. Ludwig Meier e.K.
Inhaber: Ludwig Meier
De-Gasperi-Str. 8
51469 Bergisch Gladbach
Deutschland
Tel.: +49(0)22028659300
Fax: +49(0)22028659301
E-Mail: info@buchweltweit.de
Registergericht: Amtsgericht Köln
Registernummer: HRA 28253
Umsatzsteuer-Identifikationsnummer: DE815259907
Wir sind zur Teilnahme an einem Streitbeilegungsverfahren vor einer Verbraucherschlichtungsstelle weder verpflichtet noch bereit.
Right of withdrawal
If you are a consumer you can withdraw from the contract in accordance with the following. Consumer means any natural person who is acting for purposes which are outside his trade, business, craft or profession.
Information regarding the right of withdrawal
Statutory right to withdraw
You have the right to withdraw from this contract within 14 days without giving any reason.
The withdrawal period will expire after 14 days from the day on which you acquire, or a third party other than the carrier and indicated by you acquires, physical possession of the last good or the last lot or piece.
To exercise the right of withdrawal, electronically fill in and submit a clear statement on our website, under "My Purchases" in "My Account". We will communicate to you an acknowledgement of receipt of such a withdrawal on a durable medium (e.g. by e-mail) without delay.
To meet the withdrawal deadline, it is sufficient for you to send your communication concerning your exercise of the right of withdrawal before the withdrawal period has expired.
Effects of withdrawal
If you withdraw from this contract, we will reimburse to you all payments received from you, including the costs of delivery (except for the supplementary costs arising if you chose a type of delivery other than the least expensive type of standard delivery offered by us).
We may make a deduction from the reimbursement for loss in value of any goods supplied, if the loss is the result of unnecessary handling by you.
We will make the reimbursement without undue delay, and not later than 14 days after the day on which we are informed about your decision to withdraw from this contract.
We will make the reimbursement using the same means of payment as you used for the initial transaction, unless you have expressly agreed otherwise; in any event, you will not incur any fees as a result of such reimbursement.
We may withhold reimbursement until we have received the goods back, or you have supplied evidence of having sent back the goods, whichever is the earliest.
You shall send back the goods or hand them over to BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany, without undue delay and in any event not later than 14 days from the day on which you communicate your withdrawal from this contract to us. The deadline is met if you send back the goods before the period of 14 days has expired. You will have to bear the direct cost of returning the goods. You are only liable for any diminished value of the goods resulting from the handling other than what is necessary to establish the nature, characteristics and functioning of the goods.
Exceptions to the right of withdrawal
The right of withdrawal does not apply to:
- The delivery of newspapers, journals or magazines with the exception of subscription contracts; and
- The supply of digital content which is not supplied on a tangible medium (e.g. on a CD or DVD) if you accepted when you placed your order that we could start to deliver it, and that you could not withdraw once delivery had started.
Shipping terms
Der Versand ins Ausland findet IMMER mit DHL statt. Auch nach Österreich verschicken wir nur mit DHL! Daher Standardversand == Luftpost!