National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples(Chinese Edition)
- Softcover
- New

Condition: New
£ 82.85
- Bank Wire Transfer
- Paypal
Quantity: 1 available
Add to basketItem description from seller
Ship out in 2 business day, And Fast shipping, Free Tracking number will be provided after the shipment.Paperback. Pub Date: 2012 07 Pages: 118 Language: Chinese in Publisher: China plans to Press 12SDX101-2 civil electrical design and calculation examples According to the current national standards and engineering design to actual needs. the preparation of civil electrical commonly used in the design calculations and examples for designers to use and reference. National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples include: supply and distribution system. the choice of short circuit current calculation with high and low voltage electrical relay protection calculation. wire and cable section selection and calculation of electrical lighting calculations. building lightning protection and grounding calculation. the weak systems used in the calculation of the engineering example. National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples by calculating principle calculation method. specification requirements and examples used in the process of building electrical design calculation introduced in order to design were able to correct depth understanding and mastery of building electrical design calculation methods and related regulatory requirements. Contents: cataloging a substation load calculation device power computational load to determine single-phase load peak current reactive power compensation capacity of the transformer power supply system power loss calculation of the power supply system power loss calculation and annual electricity consumption selection of high-voltage electrical calculation diesel generator capacity of UPS and EPS installed capacity of solar photovoltaic power system capacity harmonic calculation 2 short-circuit current is calculated with high and low voltage select high and low voltage electrical system short-circuit current is calculated short-circuit current of the power supply system of the diesel generator neutral point grounding device selection current transformer selection voltage transformer low-voltage electrical power transformer protection relay protection power capacitors for high-voltage power lines to protect high-voltage motor protection high voltage bus segment circuit breaker protection for the distribution system microcomputer protection design 4 wire and cable cross-section to select the selection criteria of the wire and cable cross-section to select the economic cross-section by economic current density allowable temperature rise selective cross voltage loss checksum-section by a short circuit heat stable condition check the cross-section and low voltage distribution system neutral line line of protection and protection of the cross-section of the neutral line hard busbar cross-section select 5 commonly used in electrical equipment. motor elevator 6 electrical lighting the illumination calculation estimates of the utilization factor method curve method illuminance calculated point by point calculation method the illuminance calculation 7 Building Lightning Protection calculate building expected camera lens used in the calculation of the number of lightning strikes the scope of protection lightning rod grounding resistance calculation weak project selection DVR capacity to select the video coaxial effective transmission distance calculated the calculated PA system broadcast system amplifier capacity feeder impedance matching. voltage matching calculation wired the related calculations estimate the number of cable socket estimate the number of fiber optic attenuation engine room. TV system user assigned Telecom equipment room area calculation the integrated wiring device configuration Example 9 engineering sample project overview and electrical equipment load to calculate electrical equipment load calculating transformer selection of their own emergency power supply capacity calculation of.…
Seller Inventory # NE048645
- Title
- National Building Standard Design Atlas (12SDX101-2): civil electrical design calculations and examples(Chinese Edition)
- Author
- ZHONG GUO JIAN ZHU BIAO ZHUN SHE JI YAN JIU YUAN
- Condition
- New
- Binding
- paperback
- ISBN 10
- 7802427800
- ISBN 13
- 9787802427808
"Synopsis" may belong to another edition of this title.
Shipping rates from China to U.S.A.
| Item | 16 to 30 business days | 8 to 16 business days |
|---|---|---|
| First item | £ 13.59 | £ 22.66 |
Store description
Thank you for visiting My bookstore! We are an online bookstore, and Is the China's largest online book sales. Generally our books are from China, with reasonable price and decent printing quality. We are always trying our best to satisfy customer's needs!
Specialty
Chemistry, Mathematics, Computer, Physics, Environment, Social SciencesSeller's business information
NAN JING SHI JIANG NING QU NING YUAN DIAN ZI SHANG WU ZHONG XIN
Room 264, Oujiang Shopping Center, No. 1 Dongxin South Road, Dongshan Street, Jiangning District, NanJing
Nanjing, JS China 211100
Terms of sale
We guarantee the condition of every book as it's described on the Abebooks web sites. If you're dissatisfied with your purchase (Incorrect Book/Not as Described/Damaged) or if the order hasn't arrived, you're eligible for a refund within 30 days of the estimated delivery date. If you've changed your mind about a book that you've ordered, please use the Ask bookseller a question link to contact us and we'll respond within 2 business days. Please Note:We don't sell any international Edition to you. Don't send any question about international Edition to us.
Right of withdrawal
If you are a consumer you can withdraw from the contract in accordance with the following. Consumer means any natural person who is acting for purposes which are outside his trade, business, craft or profession.
Information regarding the right of withdrawal
Statutory right to withdraw
You have the right to withdraw from this contract within 14 days without giving any reason.
The withdrawal period will expire after 14 days from the day on which you acquire, or a third party other than the carrier and indicated by you acquires, physical possession of the last good or the last lot or piece.
To exercise the right of withdrawal, electronically fill in and submit a clear statement on our website, under "My Purchases" in "My Account". We will communicate to you an acknowledgement of receipt of such a withdrawal on a durable medium (e.g. by e-mail) without delay.
To meet the withdrawal deadline, it is sufficient for you to send your communication concerning your exercise of the right of withdrawal before the withdrawal period has expired.
Effects of withdrawal
If you withdraw from this contract, we will reimburse to you all payments received from you, including the costs of delivery (except for the supplementary costs arising if you chose a type of delivery other than the least expensive type of standard delivery offered by us).
We may make a deduction from the reimbursement for loss in value of any goods supplied, if the loss is the result of unnecessary handling by you.
We will make the reimbursement without undue delay, and not later than 14 days after the day on which we are informed about your decision to withdraw from this contract.
We will make the reimbursement using the same means of payment as you used for the initial transaction, unless you have expressly agreed otherwise; in any event, you will not incur any fees as a result of such reimbursement.
We may withhold reimbursement until we have received the goods back, or you have supplied evidence of having sent back the goods, whichever is the earliest.
You shall send back the goods or hand them over to liu xing, Nanjing, JS, China, without undue delay and in any event not later than 14 days from the day on which you communicate your withdrawal from this contract to us. The deadline is met if you send back the goods before the period of 14 days has expired. You will have to bear the direct cost of returning the goods. You are only liable for any diminished value of the goods resulting from the handling other than what is necessary to establish the nature, characteristics and functioning of the goods.
Exceptions to the right of withdrawal
The right of withdrawal does not apply to:
- The delivery of newspapers, journals or magazines with the exception of subscription contracts; and
- The supply of digital content which is not supplied on a tangible medium (e.g. on a CD or DVD) if you accepted when you placed your order that we could start to deliver it, and that you could not withdraw once delivery had started.
Shipping terms
Most orders are shipped within 24 hours. We will delivery these items to you by SAL, EUB, EMS, FEDEX etc.