Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (Idms)
Language: English
Published by RSC Publishing Mai 2002, 2002
- Softcover
- New

Seller: AHA-BUCH GmbH, Einbeck, GermanyAHA-BUCH GmbH
AbeBooks seller since August 14, 2006
Condition: New
£ 81.96
Quantity: 2 available
Add to basketItem description from seller
Neuware - The isotope dilution mass spectrometry (IDMS) technique is well known and widely reported in the literature. However, its application can present considerable difficulties with regard to obtaining reliable results. Produced jointly by the Royal Society of Chemistry's Analytical Methods Committee and the Valid Analytical Measurement (VAM) programme, the aim of this book is to provide a simplified yet robust methodology, together with adequate guidance, to enable laboratories wishing to use the technique to obtain reliable data. The methodologies, for inorganic and organic mass spectrometry, which use exact and approximate matching, are illustrated with worked examples and clear diagrammatic representations. A comprehensive glossary of terms, references to key publications and an extensive IDMS bibliography are also provided. Clear and comprehensive in coverage, Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS) will provide valuable assistance to a wide variety of analytical chemists interested in applying the IDMS technique to their own measurement applications.…
Seller Inventory # 9780854044184
- Title
- Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (Idms)
- Author
- Peter Bedson
- Publisher
- RSC Publishing Mai 2002
- Publication year
- 2002
- Condition
- Neu
- Binding
- Taschenbuch
- Language
- English
- ISBN 10
- 0854044183
- ISBN 13
- 9780854044184
- Item weight
- 109 grams
- Dimensions
- 221x173x5 mm
"Synopsis" may belong to another edition of this title.
Excerpt. © Reprinted by permission. All rights reserved.
Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS)
By Chris HarringtonThe Royal Society of Chemistry
All rights reserved.
Contents
1 Introduction,
1.1 Advantages and Disadvantages of IDMS, 2,
2 The Principles of IDMS, 3,
3 Critical Stages and Sources of Error, 4,
3.1 Introduction, 4,
3.2 Sample Preparation, 5,
3.3 Selection of the Isotopic Analogue, 6,
3.4 Addition of the Isotopic Analogue, 6,
3.5 Characterisation of the Isotopic Analogue, 7,
3.6 Blank Correction, 8,
3.7 Instrumental Analysis, 8,
3.8 Calibration Procedures, 10,
3.9 Isotopic Interferences, 12,
3.10 Isotopic Discrimination, 14,
3.11 Aspects of Achieving High Accuracy Measurements, 15,
4 The Structured Approach to IDMS analysis, 17,
4.1 The 'Exact signal matching' Method for Organic IDMS, 17,
4.2 The 'Approximate signal matching' method for Inorganic IDMS, 19,
4.3 A Diagrammatic Overview of Inorganic IDMS, 22,
5 Optimised Spiking for Inorganic IDMS Analysis, 30,
5.1 Introduction, 30,
5.2 Key Parameters, 30,
Annex 1: References and Additional Reading, 35,
References, 35,
Additional Organic IDMS Publications, 36,
Additional Inorganic IDMS Publications, 38,
Annex 2: Glossary of Terms and Abbreviations, 41,
Annex 3: Standard IDMS Equations, 46,
CHAPTER 1
Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectronometry (IDMS)
1 Introduction
The technique of isotope dilution mass spectrometry (IDMS) was initially developed during the 1950s for elemental analysis. With readily available and user-friendly instrumentation, the number of applications for which elemental IDMS was used developed rapidly. IDMS was extended into the field of organic compounds in the 1970s and the range of applications for which isotopically labelled organic compounds are available continues to grow. IDMS applications range from routine survey work, such as residue analysis of dioxins, to use as a reference technique.
In mass spectrometry, unlike spectrophotometric techniques, there is no fixed relationship between the amount, and concentration, of a particular substance and the instrument response. Sensitivity for a particular compound or ion varies with, for example, time and instrumental tune parameters. These variations are in addition to those caused by, for example, sample introduction and chromatography. To achieve even moderately accurate quantification requires the use of an internal standard. An advantage of mass spectrometry lies in its ability to use isotopically enriched analogues (inorganic mass spectrometry) or isotopically labelled analogues (organic mass spectrometry) as internal standards. Indeed, in some instances IDMS is referred to as 'stable isotope internal standardisation'. Provided the isotopic analogue is added to the sample at the very beginning of the analytical method and it comes into equilibrium with the analyte without losses or isotopic fractionation, it enables exact compensation to be made for errors at all stages of the analysis, from sample digestion/preparation through to the final instrumental measurement.
Initially, IDMS of inorganic analytes was most frequently performed using thermal ionisation mass spectrometry (TIMS). More recently, inductively coupled plasma mass spectrometry (ICP-MS) based IDMS has become more prevalent, because it requires much less sample preparation prior to analysis, and can provide results of the required accuracy and precision. The inorganic sections of this guide are concerned only with the use of ICP-MS for high accuracy IDMS measurements. IDMS of organic analytes can equally well be carried out using the full range of sample inlet systems available, such as GC-MS, LC-MS and the newer technique of capillary zone electrophoresis-mass spectrometry (CZE-MS). Tandem mass spectrometers (MS-MS) can also be used. In some instances, however, the inlet system/mass spectrometer type can have an influence on IDMS analysis. The use of a GC split injector, for example, can cause isotopic fractionation.
The advent of compact and economic instrumentation, such as quadrupole and ion trap mass spectrometers, has led to the increasing use of mass spectrometry in the field of analytical chemistry. As a result, IDMS is playing an increasingly important role in trace analysis. This is also due to its greater accuracy than other calibration methods and its ability to compensate for matrix effects. Notwithstanding this, there are several reasons why, in spite of the unrivalled accuracy and precision possible with the IDMS technique, it is not more widely used. In principle, the method is simple and allows for knowledge or control of all the variables that can lead to error. In practice, achieving accurate results requires careful design of the experiment and considerable attention to detail and is hence quite time consuming. Such factors have led to a slow acceptance of the technique. It has become popular, however, in some analytical fields where the sample matrix makes sufficiently accurate quantification difficult, e.g. clinical analysis. A theoretical discussion on the influence of some instrumental parameters on the precision of IDMS measurements has been published.
1.1 Advantages and Disadvantages of IDMS
The use of IDMS has a number of advantages and disadvantages, which the prospective user should consider.
1.1.1 Advantages
Providing the sample is homogeneous and isotopic equilibrium has been reached, the advantages of IDMS include:
1. It is a definitive method because of its precision, accuracy and provision of definable uncertainty values.
2. Once equilibration of the spike and analyte isotopes has been achieved, the total recovery of the analyte is not required, because the determined value is based on measuring the ratio between the analyte and the isotopic analogue (spike).
3. The accuracy of the method is determined by the precision of this ratio measurement.
4. Analyte transformation (e.g. breakdown) during sample preparation (most applicable to organic analysis) is compensated for by use of the isotopic analogue as internal standard.
5. The methodology is less time consuming and can provide greater accuracy than standard additions.
This guide aims to provide a structured approach to the use of IDMS to achieve high accuracy analytical measurements in both organic and inorganic IDMS. The approach outlined in Sections 4 and 5 has the advantage over normal IDMS of:
1. Negating the need to accurately characterise the isotopic analogue in terms of isotopic abundance and concentration (most applicable to inorganic analysis).
2. Providing a logical framework of understanding, which allows the analyst to identify specific problems, related to their application.
3. Providing a lower uncertainty value.
4. Simplifying the equations used for organic analytes.
1.1.2 Disadvantages of IDMS
1. The cost and availability of suitable isotopic materials.
2. The cost of the mass spectrometry instrumentation required.
3. Training of the analyst is of the utmost importance; otherwise less accurate results are often achieved.
4. Isotopic equilibration needs to be shown to have been achieved.
5. Differences in the physical (e.g. solvation) and chemical properties (e.g. pKa value) between the analyte and the isotopic analogue, can affect the ions generated in the mass spectrometer (most applicable to organic analysis).
2 The Principles of IDMS
The underlying principle of IDMS5 is that an isotopically enriched analogue (inorganic MS) or an isotopically labelled analogue (organic MS) of the analyte compound is used as an internal standard in quantification by mass spectrometry. An accurately known amount of the isotopic analogue is added to the sample. The consequent ratio of the amounts of the two isotopes (one resulting from the analyte and the other from the isotopic 'spike') is measured on a portion of the sample using a mass spectrometer, so enabling the analyte concentration to be calculated. In summary the stages are:
1. Characterisation of the isotopic analogue (see Section 3.5) using a traceable natural standard by 'reverse IDMS'. If a certified isotopic analogue is used this information is provided in the certificate. This step applies primarily to inorganic analytes.
2. An accurately known amount of the isotopic analogue is then added to an accurately measured portion of the sample (see Section 3.4). This step is widely referred to as 'spiking' the sample.
3. The mixture is equilibrated for an appropriate time. For inorganic analysis destructive digestion is necessary for solid samples (see Section 3.2.1). With organic analysis sample preparation often involves extraction and purification steps. In some cases a chemical reaction is necessary to free any bound form of the analyte (e.g. conjugates) present in the sample. For analysis by gas chromatography a derivatisation step may be necessary to confer thermal stability to the analyte and spike compounds.
4. An aliquot of the spiked sample is introduced into the mass spectrometer either directly (inorganic MS) or after chromatographic separation from other compounds (organic MS) (see Section 3.7).
5. The ratio of the signal responses for the ions resulting from the mixture of the analyte and isotopic analogue is accurately measured in the spiked sample using a mass spectrometer (see Section 3.8). From this ratio the concentration of analyte is calculated by comparison with the same ratio measured for the same ions in a standard calibration mixture. The calibration mixture contains the spike used in the sample and a certified standard of the analyte.
6. Corrections need to be made for instrumental effects, such as mass bias and detector dead-time (see Section 3.10). Using the signal matching procedures outlined in this guide this can be achieved by running an alternating sequence of standards and samples.
7. Blank analysis is still required when using IDMS because any isotopic contribution to the mixture (from reagents, contamination etc.) will affect the isotopic abundance ratio and ultimately lead to a systematic bias (see Section 3.6).
3 Critical Stages and Sources of Error
3.1 Introduction
IDMS analysis can provide results of great accuracy, but to achieve that accuracy it is necessary to consider the critical stages in the experimental procedure and to understand the potential sources of error. All the general precautions associated with mass spectrometry and trace analysis apply equally well to IDMS based procedures. Issues such as sampling, sample homogeneity, contamination and losses prior to analysis will play their part in influencing the accuracy of the reported result. The purpose of this guide is to highlight the specific points pertinent to the use of IDMS for accurate measurement. Therefore, issues related to sampling etc. will not be directly addressed in this guide. For guidance on general trace analysis the following references may serve as a starting point. A useful summary of critical parameters in ICP-MS instrumentation has been published.
There are a number of critical stages in the IDMS procedure where errors may occur including:
1. Sample preparation
(a) Sample digestion and isotopic equilibration (inorganic analysis)
(b) Extraction, clean up, derivatisation (GC-MS) and isotopic equilibration (organic analysis)
2. Selection of the most appropriate isotopic internal standard (often termed the 'spike' and in this guide generically referred to as the isotopic analogue)
(a) An isotopically enriched analogue (inorganic analysis)
(b) An isotopically labelled analogue (organic analysis)
3. Addition of the isotopic analogue
4. Characterisation of the isotopic analogue
5. Blank correction
6. Instrumental analysis
7. Calibration procedure
8. Calculation of the result
9. Estimation of the uncertainty
There are a number of important sources of error in the IDMS procedure including:
1. Less than complete isotopic equilibration will lead to significant systematic errors 2. Presence of interfering ions
(a) Isobaric and polyatomic interferences (inorganic MS)
(b) Natural analyte ion signal overlap with isotopic analogue ion (organic MS)
3. Isotopic discrimination (mass fractionation, detector dead-time, mass bias)
It should be noted that errors occurring during sub-sampling, addition of the isotopic analogue, sample preparation and isotopic equilibration are not compensated for by the use of isotope dilution analysis. However, these errors can be assessed by analysis of a suitable certified reference material or an 'in-house' prepared standard, analysed alongside the sample.
The critical stages and sources of error summarised above are dealt with in greater detail in the following sections.
3.2 Sample Preparation
With IDMS it is particularly important that full equilibration between the analyte and the isotopic analogue is achieved. This will ensure identical behaviour during the analytical procedure. Sufficient time for equilibration must be allowed but, even so, it is often difficult to ensure that full equilibration has taken place. Particular attention must also be paid, for example, to the chemical forms of the analyte and the isotopic analogue, e.g. oxidation state (inorganic MS), analyte form present (organic MS) etc.
3.2.1 Inorganic IDMS
It is advantageous to add the isotopically enriched analogue at the earliest point of the analysis. For solid samples, there will be a period during the digestion phase when the analyte is in a different form from the added enriched isotope. An example of this is the analysis of trace metals in glass. The natural metal has to be released from its silicate matrix to achieve dissolution. During this period the analyte isotope may behave differently from the added analogue isotope before true equilibration is achieved. Thus, losses due to incomplete dissolution or volatile species generation can result in errors, which are unaccounted for by the IDMS procedure. Also, any contamination during the sample digestion stage will add to the final error in an IDMS analysis (this is easily corrected for by analysis of a suitable blank solution). It is essential to ensure that both isotopes are in the same chemical form. This can be achieved, for example, by an oxidation or reduction step.
3.2.2 Organic IDMS
Analyte extraction, sample clean-up and derivatisation steps may also introduce errors prior to the benefits of the isotopic spike being realised. A good example of this is the analysis of cholesterol in serum using IDMS with GC-MS measurements. Even though the serum can be spiked at an early stage with the isotopically labelled analogue this does not guarantee equilibration. In fact, the natural cholesterol is mainly bound to proteins or other lipid materials. Thus, a saponification step is required before the two forms of cholesterol are equivalent and approach equilibration. Even vigorous shaking of the unspiked sample is to be avoided, as there is evidence that foaming is linked to unwanted conversion of the indigenous cholesterol. However, it is essential that all the natural cholesterol is released, otherwise the subsequent derivatisation step for GC-MS analysis will introduce a bias between the isotopically labelled analogue and the natural form.
3.3 Selection of the Isotopic Analogue
For organic analytes, selection of the isotopically labelled analogue may have an effect on the analysis. If deuterium (D) is labelled onto an OH group, for example, then isotopic exchange may take place. Consequently the isotopic label should be introduced into a stable position of the analogue. To avoid discrimination during the various steps of the analytical procedure the label should not be in a position that affects solvation properties, pKa values or derivatisation kinetics (where applicable). When using chemical ionisation GC-MS or atmospheric pressure chemical ionisation LC-MS, if ion formation differs between the isotopic analogue and the analyte, a significant error could occur.
For inorganic analytes there are usually a limited number of options when selecting an isotopically enriched analogue for use in a given IDMS analysis. Where there is a choice, consideration should be given to possible isobaric or polyatomic interferences during the ICP-MS measurement that might be linked with a particular sample (e.g. cadmium in the presence of tin because of the isobaric interferences at m/z values of 112, 114 and 116).
3.4 Addition of the Isotopic Analogue
In general, to achieve an isotopic ion abundance ratio measurement with the best precision, the ratio of analyte concentration to isotopic analogue concentration should be such as to produce equal ion abundances. The solution for analysis should, therefore, contain similar amounts of the two isotopes. However, if measurements are to be made near the detection limit of the analyte, it is often better to use more isotopic analogue so that this response at least can be measured with greater precision.
This approach may be inappropriate for inorganic IDMS, where other situations may apply. In the case of silver, its two natural isotopes actually exist in proportions close to 1:1 (51.8% and 48.2%). Thus, the optimum spiking regime requires a final concentration ratio of ~1:4 to minimise the propagation of errors. A fuller explanation of this particular issue is given in Section 5.
In the case of organic analytes there may be some circumstances where the isotopic analogue has only a small mass difference from the natural analyte, for example, if only one carbon or hydrogen atom has been labelled. In such cases, where the isotopic analogue has a mass of only (M + 1), the analyte itself may have a significant (M + 1) abundance due to the natural isotopic composition of the analyte (contribution from 13C or 2H in the analyte). Under these circumstances a large addition (say 5 to 1) of the isotopic analogue compared to the analyte will reduce the relative concentration of the natural (M + 1) abundance compared to the (M + 1) abundance arising from the isotopic analogue. This will reduce non-linear effects arising from the natural (M + 1) abundance, and can also be particularly important where the bracketing or single point method of calibration is used (see Section 3.8). The relative molecular mass of the analogue should, wherever possible, be increased by at least three mass units, which should avoid interference of the natural isotopes of the analyte on the isotope being measured for the labelled analogue.
(Continues...)
Excerpted from Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS) by Chris Harrington. Copyright © 2002 LGC Limited. Excerpted by permission of The Royal Society of Chemistry.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.
"About the title" may belong to another edition of this title.
Shipping rates from Germany to U.S.A.
| Item | 7 to 10 business days | 5 to 7 business days |
|---|---|---|
| First item | £ 29.20 | £ 37.54 |
Payment methods
- Bank Wire Transfer
- Check
- Paypal
Store description
Das Unternehmen AHA-BUCH GmbH: Seit der Gründung von AHA-BUCH im Juli 2005 ist unser Hauptziel, zufriedenen Kunden so schnell und so preisgünstig wie möglich ihren Bücherwunsch zu erfüllen. Unsere Firma beschäftigt 16 Mitarbeiter, die nur ein Ziel kennen: den Kunden und seine Wünsche! Auf über 3700 m2 Fläche haben wir über 100.000 Bücher, Modernes Antiquariat und Spiele auf Lager.
Specialty
Kinderbücher & Kinderhör Casetten, German Books, Software, Natur & Tiere, Ratgeber, Sachbücher, Englische Bücher, Medizin & Gesundheit, Universität & StudiumSeller's business information
AHA-BUCH GmbH
Garlebsen 48
Einbeck, Germany 37574
Imprint
Seller Info:
AHA-BUCH GmbH
represented by the managing director Christel Glass
Garlebsen 48
37574 Einbeck
Deutschland
Telefon: 055639996039
Telefax: 055639995974
E-Mail: abebooks@aha-buch.de
USt-IdNr.: DE261904229
registered at Commercial register Amtsgerichtes Göttingen
Handelsregisternummer HRB 200691
Alternative dispute resolution:
The European Commission provides a platform for out-of-court online dispute resolution (ODR platform), which can be accessed under https://ec.europa.eu/odr.
We have been a member of the "FairCommerce" initiative since 25.05.2018.
For more information, see www.fair-commerce.de.
Terms of sale
General Terms and Conditions and Customer Information / Privacy Policy
I. General Terms and Conditions
§ 1 Basic provisions
(1) The following terms and conditions apply to all contracts that you conclude with us as a provider (AHA-BUCH GmbH) via the Internet platforms AbeBooks and/or ZVAB. Unless otherwise agreed, the inclusion of any of your own terms and conditions used by you will be objected to
(2) A consumer within the meaning of the following regulations is any natural person who concludes a legal transaction for purposes that can predominantly be attributed neither to their commercial nor their independent professional activity. An entrepreneur is any natural or legal person or a partnership with legal capacity who, when concluding a legal transaction, acts in the exercise of his independent professional or commercial activity.
§ 2 Conclusion of the contract
(1) The object of the contract is the sale of goods.
(2) If an article is listed by us at AbeBooks or ZVAB, the activation of the offer page at AbeBooks or ZVAB constitutes the binding offer to conclude a contract under the conditions contained in the article page.
(3) The contract is concluded via the online shopping cart system as follows:
The goods intended for purchase are stored in the "shopping cart". Via the corresponding button in the navigation bar you can call up the "shopping cart" and make changes there at any time.
After calling up the "Checkout" page and entering the personal data as well as the payment and shipping conditions, all order data will be displayed again on the order overview page.
Before sending the order, you have the option of checking all information again, changing it (also via the "back" function of the Internet browser) or cancelling the purchase.
By submitting the order via the "Buy now" button, you declare the acceptance of the offer in a legally binding manner, whereby the contract is concluded.
(4) The processing of the order and transmission of all information required in connection with the conclusion of the contract is partly automated by e-mail. You must therefore ensure that the e-mail address you have stored with us is correct, that the receipt of the e-mails is technically ensured and, in particular, that spam filters do not prevent it.
§ 3 Right of retention, retention of title
(1) You can only exercise a right of retention if it concerns claims from the same contractual relationship.
(2) The goods remain our property until full payment of the purchase price.
§ 4 Warranty
(1) The statutory warranty rights exist.
(2) In the case of used goods, the warranty period is one year from delivery of the item, deviating from the statutory regulation. The shortening of the deadline does not apply:
- culpably caused damages attributable to us from injury to life, limb or health and in the case of other damages caused intentionally or through gross negligence;
- insofar as we have fraudulently concealed the defect or have assumed a guarantee for the quality of the item.
(3) As a consumer, you are requested to check the item immediately upon delivery for completeness, obvious defects and transport damage and to inform us and the freight forwarder of any complaints as soon as possible. If you do not comply with this, this will have no effect on your statutory warranty claims.
§ 5 Choice of law, place of performance, place of jurisdiction
(1) German law shall apply. In the case of consumers, this choice of law shall only apply insofar as this does not withdraw the protection afforded by mandatory provisions of the law of the state of the consumer's habitual residence (principle of favourability).
(2) The place of performance for all services arising from the existing business relationships with us as well as the place of jurisdiction is our registered office, insofar as you are not a consumer, but a merchant, a legal entity under public law or a special fund under public law. The same applies if you do not have a general place of jurisdiction in Germany or the EU or if the domicile or habitual residence is not known at the time the action is brought. The right to appeal to the court at another statutory place of jurisdiction remains unaffected by this.
(3) The provisions of the UN Convention on Contracts for the International Sale of Goods shall expressly not apply.
II. Customer Information
- Identity of the Seller
AHA-BUCH GmbH
Garlebsen 48
D-37574 Einbeck
Germany
Telephone: 055639996039
E-mail: abebooks@aha-buch.de.
Alternative dispute resolution:
The European Commission provides a platform for out-of-court online dispute resolution (ODR platform), which can be accessed under https://ec.europa.eu/odr.
- Information on the conclusion of the contract
The technical steps for the conclusion of the contract, the conclusion of the contract itself and the correction options are carried out in accordance with the provisions "Conclusion of the contract" of our General Terms and Conditions (Part I.).
- Contract language, contract text storage
3.1. The contract language is german.
3.2. The complete text of the contract will not be stored by us. Before sending the order, the contract data can be printed out or electronically saved via the print function of the browser. After receipt of the order by us, the order data, the legally prescribed information for distance contracts and the General Terms and Conditions will be sent to you again by e-mail.
- Essential characteristics of the goods or services
The essential characteristics of the goods and/or services can be found in the respective offer.
- Prices and terms of payment
5.1. The prices stated in the respective offers as well as the shipping costs represent total prices. They include all price components including all applicable taxes.
5.2. The shipping costs incurred are not included in the purchase price. They can be called up via a correspondingly designated button on our website or in the respective offer, are shown separately in the course of the ordering process and are to be borne by you in addition, unless free shipping has been promised.
5.3. If the delivery is made to countries outside the European Union, we may incur additional costs for which we are not responsible, such as.B customs duties, taxes or money transfer fees (transfer or exchange rate fees of the credit institutions), which are to be borne by you. Any costs incurred for the transfer of money shall also be borne by you in cases where the delivery is made to an EU member state, but the payment was initiated outside the European Union.
5.4. The payment methods available to you are indicated under a corresponding button on our website or in the respective offer.
5.5. Unless otherwise stated for the individual payment methods, the payment claims from the concluded contract are due for payment immediately.
- Terms of delivery
6.1. The terms of delivery, the delivery date and, if applicable, existing delivery restrictions can be found under a correspondingly designated button on our website or in the respective offer.
Insofar as no other deadline is specified in the respective offer or under the correspondingly designated button, the delivery of the goods will take place within 3-5 days after conclusion of the contract (in the case of agreed advance payment, however, only after the time of your payment instruction).
6.2. Insofar as you are a consumer, it is regulated by law that the risk of accidental loss and accidental deterioration of the sold item during dispatch shall only pass to you upon handover of the goods, regardless of whether the shipment is insured or uninsured. This does not apply if you have independently commissioned a transport company not named by the entrepreneur or a person otherwise designated to carry out the shipment.
- Statutory liability for defects
Liability for defects is governed by the "Warranty" provision in our General Terms and Conditions (Part I).
last update: 01/06/2022
Privacy policy
Unless otherwise stated below, the provision of your personal data is neither required by law or contract, nor is it necessary for the conclusion of a contract. You are not obliged to provide the data. Failure to provide this will have no consequences. This only applies if no other information is provided in the subsequent processing operations.
Collection, processing and disclosure of personal data when placing orders
When ordering, we collect and process your personal data only to the extent necessary to fulfil and process your order and to process your enquiries. The provision of the data is necessary for the conclusion of the contract. Failure to provide this provision means that no contract can be concluded. The processing takes place on the basis of Art. 6 para. 1 lit.b GDPR and is necessary for the performance of a contract with you.
Your data will be passed on, for example, to the shipping companies and dropshipping providers selected by you, payment service providers, service providers for order processing and IT service providers.
In all cases, we strictly observe the legal requirements. The scope of data transmission is limited to a minimum.
Duration of storage
After completion of the contract, the data will first be stored for the duration of the warranty period, then taking into account legal, in particular tax and commercial retention periods and then deleted after expiry of the period, unless you have consented to further processing and use.
Rights of the data subject
If the legal requirements are met, you have the following rights under Articles 15 to 20 GDPR: Right to information, to correction, to erasure, to restriction of processing, to data portability.
In addition, pursuant to Article 21 (1) GDPR, you have the right to object to processing based on Article 6 (1) f GDPR and to processing for direct marketing purposes.
Contact us on request. The contact details can be found in our imprint.
Right to lodge a complaint with the supervisory authority
In accordance with Article 77 GDPR, you have the right to complain to the supervisory authority if you believe that the processing of your personal data is not lawful.
Right to object
If the personal data processing listed here is based on our legitimate interest pursuant to Art. 6 para. 1 lit. f GDPR, you have the right to object to this processing at any time with effect for the future for reasons arising from your particular situation.
Right of withdrawal
If you are a consumer you can withdraw from the contract in accordance with the following. Consumer means any natural person who is acting for purposes which are outside his trade, business, craft or profession.
Information regarding the right of withdrawal
Statutory right to withdraw
You have the right to withdraw from this contract within 14 days without giving any reason.
The withdrawal period will expire after 14 days from the day on which you acquire, or a third party other than the carrier and indicated by you acquires, physical possession of the last good or the last lot or piece.
To exercise the right of withdrawal, electronically fill in and submit a clear statement on our website, under "My Purchases" in "My Account". We will communicate to you an acknowledgement of receipt of such a withdrawal on a durable medium (e.g. by e-mail) without delay.
To meet the withdrawal deadline, it is sufficient for you to send your communication concerning your exercise of the right of withdrawal before the withdrawal period has expired.
Effects of withdrawal
If you withdraw from this contract, we will reimburse to you all payments received from you, including the costs of delivery (except for the supplementary costs arising if you chose a type of delivery other than the least expensive type of standard delivery offered by us).
We may make a deduction from the reimbursement for loss in value of any goods supplied, if the loss is the result of unnecessary handling by you.
We will make the reimbursement without undue delay, and not later than 14 days after the day on which we are informed about your decision to withdraw from this contract.
We will make the reimbursement using the same means of payment as you used for the initial transaction, unless you have expressly agreed otherwise; in any event, you will not incur any fees as a result of such reimbursement.
We may withhold reimbursement until we have received the goods back, or you have supplied evidence of having sent back the goods, whichever is the earliest.
You shall send back the goods or hand them over to AHA-BUCH GmbH, Einbeck, Germany, without undue delay and in any event not later than 14 days from the day on which you communicate your withdrawal from this contract to us. The deadline is met if you send back the goods before the period of 14 days has expired. You will have to bear the direct cost of returning the goods. You are only liable for any diminished value of the goods resulting from the handling other than what is necessary to establish the nature, characteristics and functioning of the goods.
Exceptions to the right of withdrawal
The right of withdrawal does not apply to:
- The delivery of newspapers, journals or magazines with the exception of subscription contracts; and
- The supply of digital content which is not supplied on a tangible medium (e.g. on a CD or DVD) if you accepted when you placed your order that we could start to deliver it, and that you could not withdraw once delivery had started.
Shipping terms
We ship your order after we received them
for articles on hand latest 24 hours,
for articles with overnight supply latest 48 hours.
In case we need to order an article from our supplier our dispatch time depends on the reception date of the articles, but the articles will be shipped on the same day.
Our goal is to send the ordered articles in the fastest, but also most efficient and secure way to our customers.
Privacy and security
Privacy policy
Unless otherwise stated below, the provision of your personal data is neither required by law or contract, nor is it necessary for the conclusion of a contract. You are not obliged to provide the data. Failure to provide this will have no consequences. This only applies if no other information is provided in the subsequent processing operations.
Collection, processing and use of personal data for orders
When ordering, we collect and use your personal data only to the extent necessary to fulfill and process your order and to process your inquiries. The provision of the data is necessary for the conclusion of the contract. Failure to provide this provision means that no contract can be concluded. The processing takes place on the basis of Art. 6 (1) lit.b GDPR and is necessary for the performance of a contract with you. Your data will not be passed on to third parties without your express consent. Excluded from this are only our service partners, which we need to process the contractual relationship or service providers whom we use in the context of order processing. In addition to the recipients named in the respective clauses of this data protection declaration, these are, for example, recipients of the following categories: shipping service providers, payment service providers, merchandise management service providers, service providers for order processing, web hosts, IT service providers and dropshipping merchants. In all cases, we strictly observe the legal requirements. The scope of data transmission is limited to a minimum.
Duration of storage
After completion of the contract, the data will first be stored for the duration of the warranty period, then taking into account legal, in particular tax and commercial retention periods and then deleted after expiry of the period, unless you have consented to further processing and use.
Rights of the data subject
If the legal requirements are met, you have the following rights under Articles 15 to 20 GDPR: Right to information, to correction, to erasure, to restriction of processing, to data portability. In addition, pursuant to Article 21 (1) GDPR, you have the right to object to processing based on Article 6 (1) f GDPR and to processing for direct marketing purposes.
Contact us on request. The contact details can be found in our imprint.
Right to lodge a complaint with the supervisory authority
In accordance with Article 77 GDPR, you have the right to complain to the supervisory authority if you believe that the processing of your personal data is not lawful.
last updated: 01/06/2022