Digital Signal and Image Processing in Jagiellonian Positron Emission Tomography
Language: English
Published by Uniwersytet Jagiellonski, Wydawnictwo, PL, 2023
- Softcover
- New

Seller: Rarewaves USA, HEBRON, KY, U.S.A.Rarewaves USA
AbeBooks seller since June 10, 2025
Condition: New
£ 38.10
Quantity: Over 20 available
Add to basketItem description from seller
Positron Emission Tomography (PET) is a key technique in the medical imaging area, which allows to diagnose the organism functions and to track the tumor changes. In PET measurement the patient is injected with radiotracer, containing a large number of metastable atoms of radionuclide, that emmits positrons. As the result of positron annihilation, the two photons travelling off with nearly opposite directions are produced and registered by detection system positioned so that it surrounds the patient body. State-of-the-art PET scanners use scintillation crystals which are characterized by high detection efficiency of annihilation photons. In this context, it is worth to mention that the Jagiellonian PET (J-PET) Collaboration developed a novel whole-body PET scanner based on plastic scintillators. They are much cheaper than crystal scintillators, which gives the opportunity to reduce the high cost of PET scanners and make them more affordable. However, plastic scintillators have much lower detection efficiency of gamma quanta compared to inorganic scintillation crystals. This can be compensated by increasing the scanner field of view and improving the time resolution in the measurement of the time of flight of gamma quanta. The J-PET scanner consists of plastic scintillator strips read out at both ends by a pair of photomultipliers and arranged axially around a cylindrical tomograph tunnel. The axial coordinate of the annihilation photon interaction point in the scintillator strip is derived from the difference of the light propagation time measured with the pair of photomultipliers. The operational principles of the J-PET scanner are similar to conventional tomographs, except that the highly accurate time information is of paramount importance. Therefore, the J-PET scanner demands a preparation of novel methods on each step of the data processing. The goal of the work presented in this dissertation is a development of the signal and image processing algorithms taking into account uniqueness of the J-PET detector. The proposed methods include: signal recovery based on samples of a waveform registered on photomultiplier output, reconstruction of position and time of interaction of annihilation photon in the scintillator strip, classification of PET events types and image reconstruction that operates exclusively in the image space. Due to the dissimilarity from the conventional PET scanners, majority of the methods presented in this dissertation are innovative solutions in digital signal and image processing in tomography.…
Seller Inventory # LU-9788323350156
- Title
- Digital Signal and Image Processing in Jagiellonian Positron Emission Tomography
- Author
- Lech Raczynski
- Publisher
- Uniwersytet Jagiellonski, Wydawnictwo, PL
- Publication year
- 2023
- Condition
- New
- Binding
- Paperback
- Language
- English
- ISBN 10
- 8323350159
- ISBN 13
- 9788323350156
- Item weight
- 666 grams
- Dimensions
- 6.69 x 0.27 x 9.61 inches
In this context, it is worth to mention that the Jagiellonian PET (J-PET) Collaboration developed a novel whole-body PET scanner based on plastic scintillators. They are much cheaper than crystal scintillators, which gives the opportunity to reduce the high cost of PET scanners and make them more affordable. However, plastic scintillators have much lower detection efficiency of gamma quanta compared to inorganic scintillation crystals. This can be compensated by increasing the scanner field of view and improving the time resolution in the measurement of the time of flight of gamma quanta. The J-PET scanner consists of plastic scintillator strips read out at both ends by a pair of photomultipliers and arranged axially around a cylindrical tomograph tunnel. The axial coordinate of the annihilation photon interaction point in the scintillator strip is derived from the difference of the light propagation time measured with the pair of photomultipliers.
The operational principles of the J-PET scanner are similar to conventional tomographs, except that the highly accurate time information is of paramount importance. Therefore, the J-PET scanner demands a preparation of novel methods on each step of the data processing. The goal of the work presented in this dissertation is a development of the signal and image processing algorithms taking into account uniqueness of the J-PET detector. The proposed methods include: signal recovery based on samples of a waveform registered on photomultiplier output, reconstruction of position and time of interaction of annihilation photon in the scintillator strip, classification of PET events types and image reconstruction that operates exclusively in the image space. Due to the dissimilarity from the conventional PET scanners, majority of the methods presented in this dissertation are innovative solutions in digital signal and image processing in tomography.
"Synopsis" may belong to another edition of this title.
About the Author
"About the title" may belong to another edition of this title.
Shipping rates within U.S.A.
| Item | 10 to 13 business days | 10 to 13 business days |
|---|---|---|
| First item | £ 0.00 | £ 0.00 |
Payment methods
Seller's business information
Rarewaves USA
10100 West Sample Road, Ste 101
Coral Springs, FL U.S.A. 33065
Right of withdrawal
If you are a consumer you can withdraw from the contract in accordance with the following. Consumer means any natural person who is acting for purposes which are outside his trade, business, craft or profession.
Information regarding the right of withdrawal
Statutory right to withdraw
You have the right to withdraw from this contract within 14 days without giving any reason.
The withdrawal period will expire after 14 days from the day on which you acquire, or a third party other than the carrier and indicated by you acquires, physical possession of the last good or the last lot or piece.
To exercise the right of withdrawal, electronically fill in and submit a clear statement on our website, under "My Purchases" in "My Account". We will communicate to you an acknowledgement of receipt of such a withdrawal on a durable medium (e.g. by e-mail) without delay.
To meet the withdrawal deadline, it is sufficient for you to send your communication concerning your exercise of the right of withdrawal before the withdrawal period has expired.
Effects of withdrawal
If you withdraw from this contract, we will reimburse to you all payments received from you, including the costs of delivery (except for the supplementary costs arising if you chose a type of delivery other than the least expensive type of standard delivery offered by us).
We may make a deduction from the reimbursement for loss in value of any goods supplied, if the loss is the result of unnecessary handling by you.
We will make the reimbursement without undue delay, and not later than 14 days after the day on which we are informed about your decision to withdraw from this contract.
We will make the reimbursement using the same means of payment as you used for the initial transaction, unless you have expressly agreed otherwise; in any event, you will not incur any fees as a result of such reimbursement.
We may withhold reimbursement until we have received the goods back, or you have supplied evidence of having sent back the goods, whichever is the earliest.
You shall send back the goods or hand them over to Rarewaves USA, Coral Springs, Florida, U.S.A., without undue delay and in any event not later than 14 days from the day on which you communicate your withdrawal from this contract to us. The deadline is met if you send back the goods before the period of 14 days has expired. You will have to bear the direct cost of returning the goods. You are only liable for any diminished value of the goods resulting from the handling other than what is necessary to establish the nature, characteristics and functioning of the goods.
Exceptions to the right of withdrawal
The right of withdrawal does not apply to:
- The delivery of newspapers, journals or magazines with the exception of subscription contracts; and
- The supply of digital content which is not supplied on a tangible medium (e.g. on a CD or DVD) if you accepted when you placed your order that we could start to deliver it, and that you could not withdraw once delivery had started.
Shipping terms
Please note that we do not offer Priority shipping to any country.
We currently do not ship to the below countries:
Afghanistan
Bhutan
Brazil
Brunei Darussalam
Channel Islands
Chile
Israel
Lao
Mexico
Russian Federation
Saudi Arabia
South Africa
Yemen
Please do not attempt to place orders with any of these countries as a ship to address - they will be cancelled.