A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r² ≥ 0.9995) in the range of 1.0–5.0 mg L⁻¹. The method demonstrated high recoveries (95%–108%) with relative standard deviations ≤ 4%, while LODs and LOQs ranged from 0.06–0.12 mg L⁻¹ and 0.21–0.38 mg L⁻¹, respectively. The results confirmed the method's reliability for quantitative detection in real textile samples.
"synopsis" may belong to another edition of this title.
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # L2-9786208433604
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Seller Inventory # I-9786208433604
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # L2-9786208433604
Quantity: Over 20 available
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In. Seller Inventory # ria9786208433604_new
Quantity: Over 20 available
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26404082745
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand. Seller Inventory # 409104358
Quantity: 4 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r 0.9995) in the range of 1.0-5.0 mg L . The method demonstrated high recoveries (95%-108%) with relative standard deviations 4%, while LODs and LOQs ranged from 0.06-0.12 mg L and 0.21-0.38 mg L , respectively. The results confirmed the method's reliability for quantitative detection in real textile samples. 60 pp. Englisch. Seller Inventory # 9786208433604
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND. Seller Inventory # 18404082739
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r ¿ 0.9995) in the range of 1.0-5.0 mg L¿ . The method demonstrated high recoveries (95%-108%) with relative standard deviations ¿ 4%, while LODs and LOQs ranged from 0.06-0.12 mg L¿ and 0.21-0.38 mg L¿ , respectively. The results confirmed the method's reliability for quantitative detection in real textile samples.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 60 pp. Englisch. Seller Inventory # 9786208433604
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - A rapid method was developed for detecting biocides in textiles that come into direct contact with human skin, as recently regulated biocides lack validated testing methods. The method focuses on analyzing four biocides: MIT, CIT, OIT, and Triclosan. Textile samples were extracted using methanolic sonication, purified through centrifugation and filtration, and analyzed using a C18 column with 0.4% acetic acid: methanol (1:1 v/v) under isocratic conditions at 280 nm wavelength. Extraction parameters were optimized, and the calibration curve showed strong linearity (r 0.9995) in the range of 1.0-5.0 mg L . The method demonstrated high recoveries (95%-108%) with relative standard deviations 4%, while LODs and LOQs ranged from 0.06-0.12 mg L and 0.21-0.38 mg L , respectively. The results confirmed the method's reliability for quantitative detection in real textile samples. Seller Inventory # 9786208433604