Recently regulated phthalates do not have validated methods for testing hence their presence cannot be estimated in the consumer products. So, a rapid, sensitive and reliable method was developed for the separation and quantitative analysis of all 28 regulated phthalate contents from the childcare items, toys, and textile test specimens. Test specimens were extracted in tetrahydrofuran at 60 ºC and 60 min sonication and purified by centrifugation and filtration. Phthalate contents were separated on a DB-5MS column using helium gas as mobile phase under Sim/Scan mode. Pre-treatment factors such as extraction solvent, extraction method, dilution ratio, extraction time were optimized. Under the optimized conditions, the targets had good linearity (r2 ≥ 0.9995) in the range of 0.2 – 10.0 mg L-1. Recoveries were between 100 ± 15 % for the target analytes. Limit of quantification (LOQs) was between 0.03 - 0.05 mg L-1. The developed analytical method has been successfully applied for extraction of regulated phthalates from real test specimens containing multiple type of matrices. Detected phthalates were in the range of 5.18 mg L-1 to 1798.14 mg L-1.
"synopsis" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 50000049-n
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # L2-9786208433598
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Shipped from UK. Established seller since 2000. Seller Inventory # L2-9786208433598
Quantity: Over 20 available
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 50000049
Seller: Grand Eagle Retail, Bensenville, IL, U.S.A.
Paperback. Condition: new. Paperback. Recently regulated phthalates do not have validated methods for testing hence their presence cannot be estimated in the consumer products. So, a rapid, sensitive and reliable method was developed for the separation and quantitative analysis of all 28 regulated phthalate contents from the childcare items, toys, and textile test specimens. Test specimens were extracted in tetrahydrofuran at 60 0C and 60 min sonication and purified by centrifugation and filtration. Phthalate contents were separated on a DB-5MS column using helium gas as mobile phase under Sim/Scan mode. Pre-treatment factors such as extraction solvent, extraction method, dilution ratio, extraction time were optimized. Under the optimized conditions, the targets had good linearity (r2 >= 0.9995) in the range of 0.2 - 10.0 mg L-1. Recoveries were between 100 15 % for the target analytes. Limit of quantification (LOQs) was between 0.03 - 0.05 mg L-1. The developed analytical method has been successfully applied for extraction of regulated phthalates from real test specimens containing multiple type of matrices. Detected phthalates were in the range of 5.18 mg L-1 to 1798.14 mg L-1. This item is printed on demand. Shipping may be from multiple locations in the US or from the UK, depending on stock availability. Seller Inventory # 9786208433598
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In. Seller Inventory # ria9786208433598_new
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 50000049-n
Quantity: Over 20 available
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26404205786
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 50000049
Quantity: Over 20 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Recently regulated phthalates do not have validated methods for testing hence their presence cannot be estimated in the consumer products. So, a rapid, sensitive and reliable method was developed for the separation and quantitative analysis of all 28 regulated phthalate contents from the childcare items, toys, and textile test specimens. Test specimens were extracted in tetrahydrofuran at 60 ºC and 60 min sonication and purified by centrifugation and filtration. Phthalate contents were separated on a DB-5MS column using helium gas as mobile phase under Sim/Scan mode. Pre-treatment factors such as extraction solvent, extraction method, dilution ratio, extraction time were optimized. Under the optimized conditions, the targets had good linearity (r2 0.9995) in the range of 0.2 - 10.0 mg L-1. Recoveries were between 100 ± 15 % for the target analytes. Limit of quantification (LOQs) was between 0.03 - 0.05 mg L-1. The developed analytical method has been successfully applied for extraction of regulated phthalates from real test specimens containing multiple type of matrices. Detected phthalates were in the range of 5.18 mg L-1 to 1798.14 mg L-1. 64 pp. Englisch. Seller Inventory # 9786208433598