This book presents the research works and investigations related to the contingency due to line outage. Firstly, the detail assessment of the impact of line outage has been studied through PV curve method. Later on, investigation has been carried out to find the most critical line in normal loading condition. In view of this, ranking of the line outage contingencies are done on the basis of proposed overall severity index (OSI) comprising of two index i.e. active power deviation-based index and voltage deviation based index. Furthermore, the critical contingency is identified though well-known L-index. Moreover, the impact of critical contingency is analysed through new indices namely voltage deviation index (VDI) and loss deviation index (LDI). The effectiveness and viability of the proposed schemes are checked on different IEEE benchmark systems in MATLAB environment.
"synopsis" may belong to another edition of this title.
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. Seller Inventory # 26397359525
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book presents the research works and investigations related to the contingency due to line outage. Firstly, the detail assessment of the impact of line outage has been studied through PV curve method. Later on, investigation has been carried out to find the most critical line in normal loading condition. In view of this, ranking of the line outage contingencies are done on the basis of proposed overall severity index (OSI) comprising of two index i.e. active power deviation-based index and voltage deviation based index. Furthermore, the critical contingency is identified though well-known L-index. Moreover, the impact of critical contingency is analysed through new indices namely voltage deviation index (VDI) and loss deviation index (LDI). The effectiveness and viability of the proposed schemes are checked on different IEEE benchmark systems in MATLAB environment. 72 pp. Englisch. Seller Inventory # 9786206158004
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand. Seller Inventory # 400066170
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND. Seller Inventory # 18397359535
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Alam MehebubDr. Mehebub Alam completed B.Tech (EE) in 2012. He obtained M.Tech (Gold Medalist) and PhD degree from NIT Durgapur in 2018 and 2023 respectively. He has published 9 research papers in international peer reviewed journals. Seller Inventory # 875209698
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. Neuware -This book presents the research works and investigations related to the contingency due to line outage. Firstly, the detail assessment of the impact of line outage has been studied through PV curve method. Later on, investigation has been carried out to find the most critical line in normal loading condition. In view of this, ranking of the line outage contingencies are done on the basis of proposed overall severity index (OSI) comprising of two index i.e. active power deviation-based index and voltage deviation based index. Furthermore, the critical contingency is identified though well-known L-index. Moreover, the impact of critical contingency is analysed through new indices namely voltage deviation index (VDI) and loss deviation index (LDI). The effectiveness and viability of the proposed schemes are checked on different IEEE benchmark systems in MATLAB environment.Books on Demand GmbH, Überseering 33, 22297 Hamburg 72 pp. Englisch. Seller Inventory # 9786206158004
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book presents the research works and investigations related to the contingency due to line outage. Firstly, the detail assessment of the impact of line outage has been studied through PV curve method. Later on, investigation has been carried out to find the most critical line in normal loading condition. In view of this, ranking of the line outage contingencies are done on the basis of proposed overall severity index (OSI) comprising of two index i.e. active power deviation-based index and voltage deviation based index. Furthermore, the critical contingency is identified though well-known L-index. Moreover, the impact of critical contingency is analysed through new indices namely voltage deviation index (VDI) and loss deviation index (LDI). The effectiveness and viability of the proposed schemes are checked on different IEEE benchmark systems in MATLAB environment. Seller Inventory # 9786206158004
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Thorough Investigations and Impact Analysis of Line Outage Contingency | Mehebub Alam (u. a.) | Taschenbuch | Englisch | 2023 | LAP LAMBERT Academic Publishing | EAN 9786206158004 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Seller Inventory # 126935282