Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1’s data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield’s influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).
"synopsis" may belong to another edition of this title.
V.A.Riaby was born in 1938 in Ukraine. In 1956 graduated from the Kalinin Suvorov Military College with golden medal, in 1962 – from the Engine Dept. of the Moscow Aviation Institute (MAI). Scientific degree of Candidate of Technical Sciences was received in 1972. Research interests/activities are in plasma physics, diagnostics & plasma technology.
"About this title" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n). 112 pp. Englisch. Seller Inventory # 9786202197380
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. 112 pages. 8.66x5.91x0.26 inches. In Stock. Seller Inventory # zk6202197382
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Seller Inventory # 385934038
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n).VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 112 pp. Englisch. Seller Inventory # 9786202197380
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Inductive low pressure xenon plasma was generated in an input section of an ion thruster. Its full diagnostics consisted of integral property measurements (Patented) and local plasma parameter determination. Accurate local diagnostics disclosed plasma parameter distributions using cylindrical Langmuir probes. Their leads were protected by conventional bare shields. Subsequent analysis showed that they distorted xenon plasma lowering all its parameters. Then probe diagnostics was specifically arranged with radially movable straight probe-1 and the additional L-shaped probe-2. They both operated in one special position: shield-1 was absent and shield-2 was non-zero disclosing measurement errors which helped to correct probe-1's data. As the result three new probe applications have been proposed: a) elimination of bare probe protective shield's influence on measurement results (Pat. Applic-n); b) measurements of the probe sheath thicknesses and the mean ion mass using cylindrical probes in Maxwellian plasmas (Patented); c) evaluation of ion current density distributions to an ion extracting electrode of an ion thruster arranged by the plane by-wall probe simulator (Pat. Applic-n). Seller Inventory # 9786202197380
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Full diagnostics of an inductive plasma section of an ion thruster | Valentin Riaby (u. a.) | Taschenbuch | 112 S. | Englisch | 2018 | LAP LAMBERT Academic Publishing | EAN 9786202197380 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Seller Inventory # 110866329