This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur (Rajasthan, India) using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2. The peak cooling load is calculated and it is 34.940Kw, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2. The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur, city situated in east of Rajasthan, India. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life.
"synopsis" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur (Rajasthan, India) using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2. The peak cooling load is calculated and it is 34.940Kw, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2. The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur, city situated in east of Rajasthan, India. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life. 96 pp. Englisch. Seller Inventory # 9786200570475
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Khan HappaKhagendra Kumar Upman is working as a Assistant Professor in AIETM Jaipur. He has done M.Tech and B.Tech from RTU Kota. Dr. B.L.Gupta is working as a Asst. Professor in GEC Bharatpur. He has completed his Ph.D from MNIT Jai. Seller Inventory # 482183362
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur (Rajasthan, India) using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2. The peak cooling load is calculated and it is 34.940Kw, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2. The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur, city situated in east of Rajasthan, India. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 96 pp. Englisch. Seller Inventory # 9786200570475
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - This book covers the performance analysis of solar thermal cooling system for a computer lab situated in Government Engineering College Bharatpur (Rajasthan, India) using Flat Plate Collector, Evacuated Tube Collector and Compound Parabolic Collector. The computer lab has the floor and roof area 198.55 m2. The peak cooling load is calculated and it is 34.940Kw, accordingly 10TR vapor absorption cooling system was adopted. The 10 TR vapour absorption system was operated by a field of collector area varying from 80-120 m2. The other parameters like hot storage tank, cold storage tank, pump, cooling tower etc are used. The simulation was carried out on TRANSOL Program for Bharatpur, city situated in east of Rajasthan, India. Sensitivity analysis shows that in coming future the as the total investment cost decreases and electricity prices increases, the payback period came down. If the total investment fall down to its 50% and electric prices are hike 50% than the payback period came down within the system life. Seller Inventory # 9786200570475
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Design and Performance Analysis of Solar Thermal Cooling System | Analysis of Solar Thermal Cooling System | Happa Khan (u. a.) | Taschenbuch | Englisch | 2021 | LAP LAMBERT Academic Publishing | EAN 9786200570475 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Seller Inventory # 120287177