Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.
"synopsis" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System. 80 pp. Englisch. Seller Inventory # 9786200284143
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. 80 pages. 8.66x5.91x0.19 inches. In Stock. Seller Inventory # zk6200284148
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Katam Ganesh BabuDr. Ganesh Babu Katam born on 24th August 1983 in Kurnool (D), Andhra Pradesh, India. In 2009 he completed B.Tech in Mechanical Engg (IPE) from G. Pulla Reddy Engg College Kurnool. In the year 2011 received M.Tech de. Seller Inventory # 385887243
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 80 pp. Englisch. Seller Inventory # 9786200284143
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Based on the available literature, the Vapour Compression Refrigeration (VCR) systems are inefficient in Nature. This is because of the usage of inefficient components in VCR System. The Expander is playing a major role in the VCR system Coefficient of Performance (COP). The refrigerants are causing to increase Global Warming due to increase in Greenhouse gases in the environment. To overcome the above issues, in the present work R134a used Two-Phase Ejector based VCR system was simulated. The simulations results are revealed that the Ejector used vapor Compressions Refrigeration (EVCR) system 19% efficient than Conventional Vapor Compressions Refrigeration (VCR) system at optimal operating parameters. Finally, it is proved that the Two-Phase Ejector can replace the Capillary tube/ expansion device in VCR System. Seller Inventory # 9786200284143