Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The improvement of microbial fuel cell (MFC) performance in a real wastewater treatment plant requires the investigation of several aspects. Firstly, a suitable cell design and electrochemical test procedure has to be set up and operated. Secondly, it is necessary to identify which electrode is the limiting electrode. Thirdly, it requires developing catalysts for the performance determining electrode. Fourthly, a method needs to be developed for the attachment of solid catalysts to the surface of the electrode. Finally, all these steps need transfer to technical scale. The data suggest that the MFC fabricated with the catalyst prepared using graphite, ¿-MnO2 and MoS2 in a weight proportion of 20:1:1 exhibited the highest optimal power density of 120 mW/m2. However, after ultrasonic treatment, the power density significantly improved to 183 mW/m2. The long term performances of the MFCs fabricated using catalysts prepared with different graphite, ¿-MnO2 (ß -MnO2) and MoS2 proportions decreased in the order of 20:1:1 (ß -MnO2) > 20:1:1 (ultrasonic) > 10:1 (ß-MnO2) >20:1:1 (¿-MnO2) > 30:2:1 (¿-MnO2) >30:1:2 (¿-MnO2). 142 pp. Englisch. Seller Inventory # 9783736998681
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. KlappentextrnrnThe improvement of microbial fuel cell (MFC) performance in a real wastewater treatment plant requires the investigation of several aspects. Firstly, a suitable cell design and electrochemical test procedure has to be set up and o. Seller Inventory # 245185901
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The improvement of microbial fuel cell (MFC) performance in a real wastewater treatment plant requires the investigation of several aspects. Firstly, a suitable cell design and electrochemical test procedure has to be set up and operated. Secondly, it is necessary to identify which electrode is the limiting electrode. Thirdly, it requires developing catalysts for the performance determining electrode. Fourthly, a method needs to be developed for the attachment of solid catalysts to the surface of the electrode. Finally, all these steps need transfer to technical scale. The data suggest that the MFC fabricated with the catalyst prepared using graphite, ¿-MnO2 and MoS2 in a weight proportion of 20:1:1 exhibited the highest optimal power density of 120 mW/m2. However, after ultrasonic treatment, the power density significantly improved to 183 mW/m2. The long term performances of the MFCs fabricated using catalysts prepared with different graphite, ¿-MnO2 (ß -MnO2) and MoS2 proportions decreased in the order of 20:1:1 (ß -MnO2) > 20:1:1 (ultrasonic) > 10:1 (ß-MnO2) >20:1:1 (¿-MnO2) > 30:2:1 (¿-MnO2) >30:1:2 (¿-MnO2).Cuvillier Verlag, Nonnenstieg 8, 37075 Göttingen 142 pp. Englisch. Seller Inventory # 9783736998681
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The improvement of microbial fuel cell (MFC) performance in a real wastewater treatment plant requires the investigation of several aspects. Firstly, a suitable cell design and electrochemical test procedure has to be set up and operated. Secondly, it is necessary to identify which electrode is the limiting electrode. Thirdly, it requires developing catalysts for the performance determining electrode. Fourthly, a method needs to be developed for the attachment of solid catalysts to the surface of the electrode. Finally, all these steps need transfer to technical scale. The data suggest that the MFC fabricated with the catalyst prepared using graphite, ¿-MnO2 and MoS2 in a weight proportion of 20:1:1 exhibited the highest optimal power density of 120 mW/m2. However, after ultrasonic treatment, the power density significantly improved to 183 mW/m2. The long term performances of the MFCs fabricated using catalysts prepared with different graphite, ¿-MnO2 (ß -MnO2) and MoS2 proportions decreased in the order of 20:1:1 (ß -MnO2) > 20:1:1 (ultrasonic) > 10:1 (ß-MnO2) >20:1:1 (¿-MnO2) > 30:2:1 (¿-MnO2) >30:1:2 (¿-MnO2). Seller Inventory # 9783736998681
Seller: Antiquariat Ehbrecht - Preis inkl. MwSt., Ilsede, Germany
Condition: Wie neu. 8°, 126 Seiten mit einigen Abbildungen, farbig betitelter OKart. - sehr guter Zustand! Wie neu - 2018. c108987 ISBN: 9783736998681 Sprache: Englisch Gewicht in Gramm: 220. Seller Inventory # 238623