The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer.
"synopsis" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 49309777-n
Seller: PBShop.store US, Wood Dale, IL, U.S.A.
PAP. Condition: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # L0-9783659758607
Seller: PBShop.store UK, Fairford, GLOS, United Kingdom
PAP. Condition: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Seller Inventory # L0-9783659758607
Quantity: Over 20 available
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 49309777
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Seller Inventory # I-9783659758607
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 49309777-n
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 49309777
Quantity: Over 20 available
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer. 88 pp. Englisch. Seller Inventory # 9783659758607
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: OHAJ MOHAMED ARTEGADr. Osama Mohammed Elmardi Suleiman Khayal was born in Atbara, Sudan in 1966. He received a bachelor degree in mechanical engineering from Sudan University of science and technology in 1998, and a master degree in. Seller Inventory # 1959525695
Quantity: Over 20 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The components of the station were studied, the data regarding breakdowns was collected. Operation reports, and times of stopping were taken during the year (2017-2021). The problems that cause the breakdowns are classified into internal and external problems and are tabled and converted into diagrams. From the analysis, it was found that the internal problems represents (73.7%) of the total problems. (58.1%) of the internal problems is found in fueling system, cooling systems, besides other main problems that range between weakness of preventive maintenance, operational errors and inappropriate work environment. The study recommends to tackle the problems through the following procedures:- Using clean tanker provided with pumping machine for fueling and pumping fuels instead of the recent used method.- The necessity to conduct continuous physical test when the station is in service and upon stoppage as well. - The necessity to use coolant water and lubricant oil that are recommended by the manufacturer. Seller Inventory # 9783659758607