The Demand for Power is increasing day to day and the resources are decaying in the same proportion.The best solution to meet the power demand in future is to convert the existing Double Circuit Three Phase Transmission lines into a compact Six Phase Transmission Line. This conversion will increase the power transfer capability to 1.732 times with in same Right-Of-Way. The other benefits are better voltage regulation, less audio & radio noise levels, low clearances etc.This Book presents the various advantages of Six Phase Transmission, Negative sequence detection in Three Phase and Six Phase Transmission System. A complete Logic Based Protection scheme by using Negative sequence currents is discussed to protect Three phase and Six Phase system against all types of faults such as Shunt, series of both Symmetrical and Unsymmetrical by using MATLAB/SIMULINK. This book initiates the further research in the area of Six Phase transmission systems.
"synopsis" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The Demand for Power is increasing day to day and the resources are decaying in the same proportion.The best solution to meet the power demand in future is to convert the existing Double Circuit Three Phase Transmission lines into a compact Six Phase Transmission Line. This conversion will increase the power transfer capability to 1.732 times with in same Right-Of-Way. The other benefits are better voltage regulation, less audio & radio noise levels, low clearances etc.This Book presents the various advantages of Six Phase Transmission, Negative sequence detection in Three Phase and Six Phase Transmission System. A complete Logic Based Protection scheme by using Negative sequence currents is discussed to protect Three phase and Six Phase system against all types of faults such as Shunt, series of both Symmetrical and Unsymmetrical by using MATLAB/SIMULINK. This book initiates the further research in the area of Six Phase transmission systems. 144 pp. Englisch. Seller Inventory # 9783659743702
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Chandra Sekhar GarlapatiDr.G.Chandra Sekhar received his B.E(EEE) in the year 1998 from Andhra University and M.Tech(EPSHVE) in the year 2001 from JNTU,Hyderabad.He has received his Ph.D from JNTU,Hyderabad.He is working in the area . Seller Inventory # 158429041
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The Demand for Power is increasing day to day and the resources are decaying in the same proportion.The best solution to meet the power demand in future is to convert the existing Double Circuit Three Phase Transmission lines into a compact Six Phase Transmission Line. This conversion will increase the power transfer capability to 1.732 times with in same Right-Of-Way. The other benefits are better voltage regulation, less audio & radio noise levels, low clearances etc.This Book presents the various advantages of Six Phase Transmission, Negative sequence detection in Three Phase and Six Phase Transmission System. A complete Logic Based Protection scheme by using Negative sequence currents is discussed to protect Three phase and Six Phase system against all types of faults such as Shunt, series of both Symmetrical and Unsymmetrical by using MATLAB/SIMULINK. This book initiates the further research in the area of Six Phase transmission systems.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 144 pp. Englisch. Seller Inventory # 9783659743702
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Logic Based Protection Of Six Phase Transmission System | Garlapati Chandra Sekhar (u. a.) | Taschenbuch | 144 S. | Englisch | 2015 | LAP LAMBERT Academic Publishing | EAN 9783659743702 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Seller Inventory # 104486830
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The Demand for Power is increasing day to day and the resources are decaying in the same proportion.The best solution to meet the power demand in future is to convert the existing Double Circuit Three Phase Transmission lines into a compact Six Phase Transmission Line. This conversion will increase the power transfer capability to 1.732 times with in same Right-Of-Way. The other benefits are better voltage regulation, less audio & radio noise levels, low clearances etc.This Book presents the various advantages of Six Phase Transmission, Negative sequence detection in Three Phase and Six Phase Transmission System. A complete Logic Based Protection scheme by using Negative sequence currents is discussed to protect Three phase and Six Phase system against all types of faults such as Shunt, series of both Symmetrical and Unsymmetrical by using MATLAB/SIMULINK. This book initiates the further research in the area of Six Phase transmission systems. Seller Inventory # 9783659743702