The heart of the data processing activities of a modern electric utility energy control center is the power system state estimator. A state estimator provides the same information on-line that are provided by a load flow study off-line. This information is used for contingency evaluation, security assessment, control strategy and economic dispatch. An energy control center gathers information on the state of a power system that may include large errors which called bad data. In view of the above consideration, it is necessary to have a method to establish a reliable and complete data base for on-line monitoring and control. In this book, the fast supper decoupled state (FSDS) estimator is developed and applied to systems having low as well as high R/X ratio lines, well-behaved systems, ill-conditioned systems as well as bad data processing. The FSDS estimator is investigated using a single-rotation angle for all measurements. Comparisons are made with respect to the fast decoupled state estimator. The FSDS estimator is found to be efficient and effective especially for systems having high R/X ratio lines, ill-conditioned system and bad data.
"synopsis" may belong to another edition of this title.
Dr. Ehab Elattar obtained his B.Sc. and M.Sc. degrees in Electrical Engineering from Elec. Eng. Dep., Menofia University, Egypt in 1999 and 2003, respectively, and the Ph.D. degree in 2010 from the Dep. of Elec. Eng., University of Liverpool, UK. His research interests include power system analysis, economic operation and optimization.
"About this title" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The heart of the data processing activities of a modern electric utility energy control center is the power system state estimator. A state estimator provides the same information on-line that are provided by a load flow study off-line. This information is used for contingency evaluation, security assessment, control strategy and economic dispatch. An energy control center gathers information on the state of a power system that may include large errors which called bad data. In view of the above consideration, it is necessary to have a method to establish a reliable and complete data base for on-line monitoring and control. In this book, the fast supper decoupled state (FSDS) estimator is developed and applied to systems having low as well as high R/X ratio lines, well-behaved systems, ill-conditioned systems as well as bad data processing. The FSDS estimator is investigated using a single-rotation angle for all measurements. Comparisons are made with respect to the fast decoupled state estimator. The FSDS estimator is found to be efficient and effective especially for systems having high R/X ratio lines, ill-conditioned system and bad data. 132 pp. Englisch. Seller Inventory # 9783659182976
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. pp. 132. Seller Inventory # 26127790001
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Elattar Ehab E.Dr. Ehab Elattar obtained his B.Sc. and M.Sc. degrees in Electrical Engineering from Elec. Eng. Dep., Menofia University, Egypt in 1999 and 2003, respectively, and the Ph.D. degree in 2010 from the Dep. of Elec. Eng., . Seller Inventory # 5137701
Quantity: Over 20 available
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand pp. 132 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. Seller Inventory # 132797550
Quantity: 4 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND pp. 132. Seller Inventory # 18127790011
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -The heart of the data processing activities of a modern electric utility energy control center is the power system state estimator. A state estimator provides the same information on-line that are provided by a load flow study off-line. This information is used for contingency evaluation, security assessment, control strategy and economic dispatch. An energy control center gathers information on the state of a power system that may include large errors which called bad data. In view of the above consideration, it is necessary to have a method to establish a reliable and complete data base for on-line monitoring and control. In this book, the fast supper decoupled state (FSDS) estimator is developed and applied to systems having low as well as high R/X ratio lines, well-behaved systems, ill-conditioned systems as well as bad data processing. The FSDS estimator is investigated using a single-rotation angle for all measurements. Comparisons are made with respect to the fast decoupled state estimator. The FSDS estimator is found to be efficient and effective especially for systems having high R/X ratio lines, ill-conditioned system and bad data.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 132 pp. Englisch. Seller Inventory # 9783659182976
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The heart of the data processing activities of a modern electric utility energy control center is the power system state estimator. A state estimator provides the same information on-line that are provided by a load flow study off-line. This information is used for contingency evaluation, security assessment, control strategy and economic dispatch. An energy control center gathers information on the state of a power system that may include large errors which called bad data. In view of the above consideration, it is necessary to have a method to establish a reliable and complete data base for on-line monitoring and control. In this book, the fast supper decoupled state (FSDS) estimator is developed and applied to systems having low as well as high R/X ratio lines, well-behaved systems, ill-conditioned systems as well as bad data processing. The FSDS estimator is investigated using a single-rotation angle for all measurements. Comparisons are made with respect to the fast decoupled state estimator. The FSDS estimator is found to be efficient and effective especially for systems having high R/X ratio lines, ill-conditioned system and bad data. Seller Inventory # 9783659182976
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Static State Estimation for Power Systems | Fast supper decoupled state estimator, ill-conditioned systems and bad data processing | Ehab E. Elattar (u. a.) | Taschenbuch | 132 S. | Englisch | 2014 | LAP LAMBERT Academic Publishing | EAN 9783659182976 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Seller Inventory # 105400419