There are several designs and techniques for measuring the ac voltage. The ac-dc thermal transfer standards represent the common method for measuring the ac voltage accurately in terms of the dc voltage. The single junction thermal converter (SJTVC) is widely used as thermal transfer standard. It is to be noted that the SJTVC is mainly an electric resistor (heater) whose temperature is sensed by a standard thermocouple. This device has an input which is ac voltage and an output signal represented by the output voltage of the thermocouple. This thermal converter suffers from many drawbacks such as, it has low dc output voltage requiring accurate milli-voltmeter to measure it. This leads to high uncertainty and not very high accuracy of ac voltage measurement. These drawbacks are studied and treated in this thesis through fabricating of modified designs TVCs. The suggested solution depends on three different electrical connections of a number of new single junction vacuum thermocouples their heaters leads gathered in three groups; Series, Parallel and Series/Parallel arrangements. The modified TVCs are implemented entirely in National Institute for Standards (NIS), Egypt.
"synopsis" may belong to another edition of this title.
Rasha S. M. Ali born on 2nd of August, 1979. Graduated from Faculty of Engineering, Ain Shams University from 2001. I worked as researcher in the national institute for standards from 2003 in the electrical quantities metrology laboratory. The master degree was taken from Faculty of Engineering, Ain Shams University in 2005 and the Ph.D in 2009.
"About this title" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -There are several designs and techniques for measuring the ac voltage. The ac-dc thermal transfer standards represent the common method for measuring the ac voltage accurately in terms of the dc voltage. The single junction thermal converter (SJTVC) is widely used as thermal transfer standard. It is to be noted that the SJTVC is mainly an electric resistor (heater) whose temperature is sensed by a standard thermocouple. This device has an input which is ac voltage and an output signal represented by the output voltage of the thermocouple. This thermal converter suffers from many drawbacks such as, it has low dc output voltage requiring accurate milli-voltmeter to measure it. This leads to high uncertainty and not very high accuracy of ac voltage measurement. These drawbacks are studied and treated in this thesis through fabricating of modified designs TVCs. The suggested solution depends on three different electrical connections of a number of new single junction vacuum thermocouples their heaters leads gathered in three groups; Series, Parallel and Series/Parallel arrangements. The modified TVCs are implemented entirely in National Institute for Standards (NIS), Egypt. 204 pp. Englisch. Seller Inventory # 9783659115721
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Ali Rasha S.M.Rasha S. M. Ali born on 2nd of August, 1979. Graduated from Faculty of Engineering, Ain Shams University from 2001. I worked as researcher in the national institute for standards from 2003 in the electrical quantities . Seller Inventory # 5132426
Quantity: Over 20 available
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - There are several designs and techniques for measuring the ac voltage. The ac-dc thermal transfer standards represent the common method for measuring the ac voltage accurately in terms of the dc voltage. The single junction thermal converter (SJTVC) is widely used as thermal transfer standard. It is to be noted that the SJTVC is mainly an electric resistor (heater) whose temperature is sensed by a standard thermocouple. This device has an input which is ac voltage and an output signal represented by the output voltage of the thermocouple. This thermal converter suffers from many drawbacks such as, it has low dc output voltage requiring accurate milli-voltmeter to measure it. This leads to high uncertainty and not very high accuracy of ac voltage measurement. These drawbacks are studied and treated in this thesis through fabricating of modified designs TVCs. The suggested solution depends on three different electrical connections of a number of new single junction vacuum thermocouples their heaters leads gathered in three groups; Series, Parallel and Series/Parallel arrangements. The modified TVCs are implemented entirely in National Institute for Standards (NIS), Egypt. Seller Inventory # 9783659115721
Seller: Mispah books, Redhill, SURRE, United Kingdom
Paperback. Condition: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Seller Inventory # ERICA796365911572X6
Quantity: 1 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - Print on Demand Titel. Neuware -There are several designs and techniques for measuring the ac voltage. The ac-dc thermal transfer standards represent the common method for measuring the ac voltage accurately in terms of the dc voltage. The single junction thermal converter (SJTVC) is widely used as thermal transfer standard. It is to be noted that the SJTVC is mainly an electric resistor (heater) whose temperature is sensed by a standard thermocouple. This device has an input which is ac voltage and an output signal represented by the output voltage of the thermocouple. This thermal converter suffers from many drawbacks such as, it has low dc output voltage requiring accurate milli-voltmeter to measure it. This leads to high uncertainty and not very high accuracy of ac voltage measurement. These drawbacks are studied and treated in this thesis through fabricating of modified designs TVCs. The suggested solution depends on three different electrical connections of a number of new single junction vacuum thermocouples their heaters leads gathered in three groups; Series, Parallel and Series/Parallel arrangements. The modified TVCs are implemented entirely in National Institute for Standards (NIS), Egypt.OmniScriptum SRL, Str. Armeneasca 28/1, office 1, 2012 Chisinau 204 pp. Englisch. Seller Inventory # 9783659115721
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. Design and Implementation of Thermal Converter for AC Volt Measurement | Characteristics, Modeling and Confirmation | Rasha S. M. Ali | Taschenbuch | 204 S. | Englisch | 2012 | LAP LAMBERT Academic Publishing | EAN 9783659115721 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Seller Inventory # 106490287