Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis.
"synopsis" may belong to another edition of this title.
I got my first university degree in Biomedical Engineering.Having Graduated,I got a seat in master of medical radiation engineering in my homeland IRAN.I then pursued my education in master of advanced studies in Medical Physics at International centre for theoretical physics(ICTP) and I am currently a PhD scholar at University of Trieste(Italy).
"About this title" may belong to another edition of this title.
Seller: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Germany
Taschenbuch. Condition: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis. 52 pp. Englisch. Seller Inventory # 9783330023949
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. 52 pages. 8.66x5.91x0.12 inches. In Stock. Seller Inventory # __3330023945
Quantity: 1 available
Seller: moluna, Greven, Germany
Condition: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Aslian HosseinI got my first university degree in Biomedical Engineering.Having Graduated,I got a seat in master of medical radiation engineering in my homeland IRAN.I then pursued my education in master of advanced studies in Medica. Seller Inventory # 158247005
Quantity: Over 20 available
Seller: buchversandmimpf2000, Emtmannsberg, BAYE, Germany
Taschenbuch. Condition: Neu. Neuware -Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis.Books on Demand GmbH, Überseering 33, 22297 Hamburg 52 pp. Englisch. Seller Inventory # 9783330023949
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Plan optimization and verification in complex treatment delivery techniques such as IMRT and VMAT have been the two major subjects. Because the importance of precise treatment planning and accurate dose delivery is imperative to minimize any possible error in leaf speed, dose rate and gantry rotation. In this work, first the effectiveness of MONACO, which has EUD-based biological optimization combined with physical and radiobiological cost functions and some important parameters in VMAT plan optimization have been studied. Then, dose delivery of different VMAT plans such as Head and Neck (SIB: Simultaneously Integrated Boost), lung (SBRT: Stereotactic Body Radiation Therapy) and prostate (Hypo-fractionated intensity modulated arc therapy) with the Octavius 4D system has been evaluated using gamma index analysis. Seller Inventory # 9783330023949
Seller: preigu, Osnabrück, Germany
Taschenbuch. Condition: Neu. VMAT plans and delivery verification using MONACO TPS and Octavius 4D | Evaluation of simple to more complex VMAT Plans | Hossein Aslian (u. a.) | Taschenbuch | 52 S. | Englisch | 2017 | LAP LAMBERT Academic Publishing | EAN 9783330023949 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Seller Inventory # 108360170
Seller: Mispah books, Redhill, SURRE, United Kingdom
paperback. Condition: New. NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Seller Inventory # ERICA82933300239456