Items related to NMR-based Metabolomics: Volume 14 (New Developments...

NMR-based Metabolomics: Volume 14 (New Developments in NMR) - Hardcover

 
9781849736435: NMR-based Metabolomics: Volume 14 (New Developments in NMR)

Synopsis

This book describes the state of the art in the application of NMR spectroscopy to metabolomics and will be a key title for researchers and practitioners.

"synopsis" may belong to another edition of this title.

From the Back Cover

In the rapidly growing field of metabolomics, a comprehensive book describing the state of the art in the application of NMR spectroscopy will be a key title for practitioners. Providing a unique resource of background knowledge, resources, instrumental platforms and software, this book will introduce relevant theory to the researcher as well as serve as a practical guide detailing key experiments and data handling procedures. Information available on common sample types will be described together with reference to the latest web-based resources available. Application-specific considerations will be discussed for a wide range of research topics. Written by a expert team as a service to the metabolomics community, this book will appeal to NMR spectroscopist, analytical chemist and biochemists especially those with an interest in medical applications.

Excerpt. © Reprinted by permission. All rights reserved.

NMR-based Metabolomics

By Hector C. Keun

The Royal Society of Chemistry

Copyright © 2018 The Royal Society of Chemistry
All rights reserved.
ISBN: 978-1-84973-643-5

Contents

Chapter 1 Instrumental Platforms for NMR-based Metabolomics Anthony C. Dona, 1,
Chapter 2 NMR Pulse Sequences for Metabolomics Bénédicte Elena-Herrmann, 22,
Chapter 3 NMR Spectroscopy of Urine Barry Slaff, Arjun Sengupta and Aalim Weljie, 39,
Chapter 4 NMR Spectroscopy of Serum and Plasma Hector C. Keun, 85,
Chapter 5 High-resolution Magic-angle Spinning (HR-MAS) NMR Spectroscopy Alan Wong and Covadonga Lucas-Torres, 133,
Chapter 6 Investigation of Tumor Metabolism by High-resolution Magic-angle Spinning (HR-MAS) Magnetic Resonance Spectroscopy (MRS) May-Britt Tessem, Siver A. Moestue and Tone F. Bathen, 151,
Chapter 7 NMR in Environmental and Nutritional Research Toby J. Athersuch and Anisha Wijeyesekera, 168,
Chapter 8 NMR Foodomics Francesco Savorani, Bekzod Khakimov, Nanna Viereck and Søren Balling Engelsen, 183,
Chapter 9 NMR-based Metabolomics: Understanding Plant Chemistry and Identification of Biologically Active Compounds M. Jahangir, T. R. Nuringtyas, K. Ali, E. G. Wilson, Y. H. Choi and R. Verpoorte, 246,
Chapter 10 1H NMR-based Metabolic Profiling in Infectious Disease Research Jasmina Saric, Sabrina D. Lamour and Jia V. Li, 264,
Chapter 11 Imaging Metabolic Processes in Living Systems with Hyperpolarised 13C Magnetic Resonance Deborah K. Hill, Erika Mariotti and Thomas R. Eykyn, 280,
Chapter 12 Advances in Computational Analysis of Metabolomic NMR Data Timothy M. D. Ebbels, Andrea Rodriguez-Martinez, Marc-Emmanuel Dumas and Hector C. Keun, 310,
Chapter 13 NMR Spectroscopy of Cell Culture, Tissues, and Other Biofluids Toby J. Athersuch, Chung-Ho Lau, Volker Behrends and Hector C. Keun, 324,
Subject Index, 360,


CHAPTER 1

Instrumental Platforms for NMR-based Metabolomics

Anthony C. Dona

MRC-NIHR National Phenome Centre, Department of Surgery & Cancer, Imperial College of London, South Kensington Campus SW7 2AZ, United Kingdom

* E-mail: anthony.dona@sydney.edu.au


1.1 History of NMR Hardware Development

The basic function of an NMR spectrometer is to measure the frequency of the resonance of a given nucleus. After the first decade of discovery (1946–1955), the basic NMR relationship was established (eqn (1.1)), which suggests the resonance frequency of a nucleus (?) to the magnetogyric ratio (?, specific to nucleus type) and the external magnetic field (B).

? = ?B (1.1)

At this stage it was thought that the frequency of a nucleus depended entirely on the strength of the magnetic field in which it was placed. In 1949–1950, however, observations from 19F and 31P showed variations in frequency between the two types of nucleus beyond the still rather large experimental error. Furthermore, after developments in the stability and homogeneity of the magnetic field, two separate resonances where observed from the hydrogen atoms in ethanol and separately for nitrogen atoms in different chemical environments. This phenomenon soon became known as 'chemical shift' as the frequency of a resonating nucleus is largely dependent on the local chemical environment surrounding the nucleus itself. Further improvements in the resolution allowed separate resonance lines to be observed from a single chemical resonance, allowing the discovery of the concepts of indirect spin–spin coupling or scalar coupling. In the late 1950s and the into the 1960s the strength of the field increased to 100 MHz and commercial instruments were developed by Varian that maintained a constant relationship between the magnetic field and the radiofrequency (RF) applied so spectra could be recorded at a known scan rate. In this time the first 13C spectrum was recorded, made difficult at the time by the low natural abundance of 13C atoms (1.1%). Carbon spectroscopy really became popular with the advent of double resonance, where two RF fields are applied to a sample simultaneously in order to measure one spin system while the other is perturbed. From double resonance, applications such as spin decoupling experiments and nuclear Overhauser effect (nOe) were introduced to aid studies of molecular conformation.

In 1966, Ernst and Anderson published work showing that Fourier Induction Decay (FID) following a short RF pulse was all that was necessary to produce a spectrum measuring a range of frequencies. Additionally, minicomputers were being developed to interface directly with the spectrometer, allowing Fourier Transform NMR (FT-NMR). These hardware advances revolutionised NMR spectroscopy, supporting the enhancement of sensitivity (which was NMR's main disadvantage compared with other spectroscopy techniques) and enabling exploitation of time-dependent NMR phenomenon, namely relaxation.

Since these major advances in NMR hardware, many pulse sequences and applications have developed over the last 40 years, making NMR spectroscopy an incredibly versatile tool in chemical and biochemical research areas. Magnetic Resonance Imaging (MRI) was also made possible by imposing magnetic field gradients across a sample in vivo. Two-dimensional and eventually three-dimensional NMR imaging was made possible with wide bore magnets (wide enough to fit animals or humans through) and the measure of a frequency across a spatial gradient. Techniques are also currently being produced to integrate spectroscopy with imaging to obtain localised spectra in living creatures.

These days, the hardware available for modern-day NMR measurements allows for routine acquisitions with relative ease, in small (metabolite, organically synthesised) and large (protein) molecules, in either purified solutions (for molecular structure elucidation) or complex mixtures (for solution composition elucidation).

1.2 Components of NMR Hardware

1.2.1 Magnet

The NMR magnet itself is generally considered the most important part of the NMR spectrometer and is commonly the most expensive piece of equipment for a standard NMR laboratory. Before the advent of superconducting magnets, iron-core electromagnets had enabled field strengths of 2.35 T to be reached. At this stage iron saturates, so a great effort was required to develop a magnet that could be housed in a liquid helium Dewar to obtain the temperatures required to cool a superconducting solenoid. Today, commercial NMR magnets are generally superconducting and range in field strength from 6 to 23.5 T. Other physical chemistry laboratories are developing larger magnets, not intended for commercial distribution, with magnetic field strengths of up to 45 T. With increasing strength, not only does the size of the magnet need to increase but technologies need to be developed to break ground in new magnet generation. As magnets increase in size (and so magnetic field strength) their resolution and sensitivity of frequencies improves, but their cost also increases substantially, meaning larger magnets are much less accessible.

Superconducting wires are generally made from Nb3Sn or (NbTaTi)3Sn, which are wrapped hundreds of times into a coil making up a length of wire up to 100 km long. Few higher temperature superconducting materials are suitable for manufacturing in the quality and quantity required for NMR magnets, so very low temperature superconductors (~10 K) are usually constructed. The wire has a rectangular cross section allowing maximum current density and therefore maximum magnetic field strength. This coil is kept inside a large Dewar containing liquid helium, keeping the coil at superconducting temperatures, which is in turn surrounded by a liquid nitrogen reservoir acting as a buffer between the room temperature air and the liquid helium. A significant property of the wire is the maximum critical current (Ic), which is a function of the operational temperature (T) and magnetic field (B). If the critical value is reached there is a transition in the wire from a superconductive to a resistive state, which in turn generates heat. The heat propagates rapidly through the coil prompting the energy store to be converted to heat, which induces the helium store to boil extremely rapidly. The loss of the superconductive state is known as a 'quench' and magnetic coils are developed to avoid quenches at all costs. Modern day magnets have an additional coil outside the main coil, which is used to contain the strong magnetic field by cancelling (shielding) the stray field, restricting it to a relatively small area.

The cryostat, which is the vessel surrounding the magnetic coil, must also be designed to be insensitive to variations in the environment and other disturbances such as helium evaporation rate, ambient temperature and pressure, and the cryogen levels inside the cryostat. New technologies in this area are focused around either using the complete enthalpy stored in the helium gas to enable further cooling of the system or otherwise recycling helium such that it is not lost to the atmosphere. These technologies are aimed at having the lowest possible helium consumption as it becomes a rarer and more expensive commodity.

NMR laboratories are often forced to compromise on magnetic field strength owing to available funding and space. Modern day magnets between 400 and 600 MHz are commonplace in metabolomics laboratories as they are now constructed to fit in a room without roof height modification. With modern day shielding, the footprint required for the magnetic field is not much larger than the magnet itself and so magnets of this size can essentially be lined up next to one another. Magnets of 600 MHz are produced much more readily than those of larger size and so the production cost is far cheaper and more reliable, making them the magnet size of choice for routine metabolomics studies. On the other hand, magnet sizes smaller than 400 MHz do not enable researchers to resolve important metabolite signatures in complex biofluids and so these are generally overlooked when purchasing a magnet for metabolomics purposes.


1.2.2 Shim Coils

Shim coils are a set of conducting coils used to adjust the homogeneity of a magnetic field. In the past, shimming (the process of optimising the homogeneity of the magnetic field) a magnet consisted of attaching thin metal shims in various positions around the permanent magnet. Coincidently, the term 'shimming' is used to describe the modern day process of homogenising the magnetic field across which the samples nuclei frequencies are measured. Modern high-resolution spectrometers alter the current in various conducting coils, which surround the external magnetic field, to alter it homogeneity.

When a spectrometer is installed, the local environment can disturb the magnetic field. Iron constructs in the walls and floor of the surrounding building disturb the homogeneity of the spectrometer's magnetic field. Therefore, upon installation spectrometers need to be roughly shimmed, after the initial activation of the magnetic field, with regards to the external environment. Once relative homogeneity is achieved, relatively minor changes in the magnetic field as a result of variations in the sample, the tube thickness and movement of ferromagnetic materials around the magnet are corrected before sample acquisition. These minor changes in the magnetic field are adjusted by changing the current in one or more (of up to 40) small shim coils with various gradients along all three spatial axes. In high-resolution spectrometers the magnetic field often demands homogeneity better than 1 part per billion in a tube, which is generally less than a millilitre in volume.


1.2.3 Sample Probe

The probe is the part of the spectrometer that does a lot of the physical experimental work and laboratories can often gain significant improvements in spectral quality by upgrading their spectrometer's probe. The probe contains the RF coils tuned to specific frequencies to excite particular nuclei and coils to detect the NMR signal. Pulsed Field Gradient coils, which allow for the application of field gradients, are also commonplace, allowing for the application of field-gradient pulses. The probe must also consist of the necessary hardware to measure and control the temperature of samples (a thermocouple device).

An important aspect of probe design is the size of the bore, which can alter to accommodate various sizes of tube. Small volume probes (3 mm) or nanotubes (1.7 mm) are able to give the greatest sensitivity, benefiting from the dramatic decrease in the diameter of the NMR detection coil. Some modern day probes are able to record good quality spectra from microlitre or even picolitre sample volumes. Nevertheless, in many cases larger volume bores (5 mm, 10 mm or wide bore) are necessary as the solubility or concentration of the sample is an issue. Larger volume bores are also recommended when measuring samples of higher viscosity or samples with micro-scale inhomogeneities (blood or emulsions), and are necessary when imaging small animals.

1.2.3.1 Radiofrequency Coils Modern day probes are constructed with two coils to record NMR signal (known as observe coils). They are wrapped around one another such that there is an inner coil and an outer coil, allowing the probe to respond to different frequencies during the one experiment. This design also allows multiple nuclei to be excited during one pulse sequence. There are two main approaches to the design of these coils:

- A 'Broadband Observe Probe' is constructed with the inner coil tuned to a broadband nucleus, and so is optimised for maximum sensitivity for nuclei at lower frequency (13C, 31P, etc.).

- 'Inverse Probes' or 'Indirect Detection Probes' have the inner coil tuned to measure the frequency of 1H atoms and so get maximum sensitivity for proton experiments with much lower sensitivity when observing lower frequency nuclei.


1.2.3.2 Cryoprobes

Sensitivity of detection has dramatically improved with the advent of cryoprobes. These probes are significantly more expensive in design but ensure 2–4 times better sensitivity than standard probes. Cryoprobes have achieved the single largest jump in sensitivity enhancement by probe development in the last few decades by cryogenically cooling probe detector coils and preamplifier coils. As long as these coils, along with the tuning and matching circuits, are maintained at low temperatures the noise generated owing to random thermal motion of electrons is kept at a minimum. The resistivity in metals based in the preamplifier and filters is also cooled, improving the level of noise generated owing to the probe's electronic components. There are currently two types of cryoprobe available, the first is cooled a by closed cycle helium cooler system, which yields a signal-to-noise enhancement up to a factor of five. The second type is a liquid nitrogen-cooled system, which has the advantage of being able to be cooled down and warmed up relatively quickly, although is only able to provide a sensitivity enhancement of up to a factor of three. Either one of these probes is generally applied to compensate for the lack of sensitivity owing to magnet strength, or simply to enhance a laboratory's run time capability.


1.2.3.3 Microprobes

The development of microprobes (or microcoil probes) was driven by the pharmaceutical industry where detection of small sample amounts was required with a relatively high throughput rate. The heart of the problem lied in developing a system with increased sensitivity for small sample volumes. The solution was simply to reduce the diameter of the RF coils; microprobes are generally considered to have an RF coil of less than 1.6 mm inner diameter. Therefore, there are few differences between standard NMR probes and microcoil probes apart from the fundamental sample volume required. However, as the volume required is much less, the microprobes allow for many more molecular biological applications.

While regular volume probes are based on Helmholtz saddle coils (coils that lie parallel to the external magnetic field), microprobes of less than 45 µL require a detection coil, which is typically a solenoid, that is placed orthogonal to the external magnetic field. The sample insertion into the magnetic field therefore cannot be performed traditionally from the top of the magnet using a conventional NMR tube. Sample insertion into a solenoidal coil is generally controlled by a flow injection probe (Section 1.2.3.4). Solenoidal probe interfaces are advantageous as they have a sensitivity level about 2–3 times larger than a traditional coil and only need an order of magnitude 1–2 times less than traditional NMR probes.


1.2.3.4 Flow Injection Probes

Flow injection probes were historically the first approach to conducting high-throughput NMR. Physically a flow probe contains a glass chamber within the RF coils with a total volume of between 1 µL and 120 µL. Flow injection probes with volumes less than 10 µL are considered to be 'microcoil' flow probes (Section 1.2.3.3). The probe contains an inlet for solution to enter the chamber and an outlet for the sample to be evacuated and rinsed out. The probes can either be 'stop-flow', which means during the time of acquisition the sample is motionless in the probe's chamber, or alternately the probe can be 'on-flow' where the sample is flowing during the short analytical measurement of the sample by NMR. When using an on-flow probe, though, the shim quality is compromised owing to the flowing solution making it difficult to homogenise the magnetic field. Therefore, the results from an on-flow probe are generally less resolved than a stop-flow probe, although the throughput is higher. Furthermore, the concentration of the metabolites of interest in the flowing sample needs to be considered before a measurement and optimisation of the methodology for each sample type is almost always necessary.

All flow techniques can be classified into one of two further separate categories. The first simply uses flow injection as a means to transport an untreated sample into the NMR analysis coil (almost always performed in a stop-flow environment to better distinguish samples and improve the shim quality), simplifying automation and speeding up throughput. The second category subjects the sample to a separation technique such as chromatography or electrophoresis before NMR analysis and can be performed in either stop-flow (separating fractions) or on-flow (continuous analysis of the probe's contents, which can be later processed separately). Flow injection probes have had many applications over the last couple of decades and more recently have been successfully applied to metabolic profiling of biofluids.


(Continues...)
Excerpted from NMR-based Metabolomics by Hector C. Keun. Copyright © 2018 The Royal Society of Chemistry. Excerpted by permission of The Royal Society of Chemistry.
All rights reserved. No part of this excerpt may be reproduced or reprinted without permission in writing from the publisher.
Excerpts are provided by Dial-A-Book Inc. solely for the personal use of visitors to this web site.

"About this title" may belong to another edition of this title.