This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation.
"synopsis" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 21606325-n
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Print on Demand. Seller Inventory # I-9781499140118
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 21606325
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 21606325
Quantity: Over 20 available
Seller: THE SAINT BOOKSTORE, Southport, United Kingdom
Paperback / softback. Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Seller Inventory # C9781499140118
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 21606325-n
Quantity: Over 20 available
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. This report provides key results of a six-month feasibility study on the effects of normal aging on the performance of pressure transmitters in nuclear power plants. Using experimental methods for response time testing of transmitters and aging tests on representative transmitters, the authors found that five reasonably effective methods are available for response time testing of pressure transmitters, two of which provide on-line measurement capability. The authors show that 38 percent of the problems reported in the 1,325 cases of the U.S. NRC's Licensee Event Report database over a nine-year period involved potential age-related cases such as calibration shifts and response time degradation. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Seller Inventory # 9781499140118
Quantity: 1 available