A linear-fit method of rating residential-type air conditioning systems was evaluated based on performance predictions and laboratory testing of one two-speed matched system and two mixed systems (matched two-speed condensing unit, matched indoor coil blower, and two mixed coil blowers). The individual evaporators and the condensing unit were separately tested using water heated/cooled condensing/evaporating units at standard air conditions over a range of evaporator refrigerant saturation temperatures, evaporator superheats, and liquid refrigerant temperatures. Capacity predictions were within ±1.0 % of the tested values for the mixed systems, and the EER predictions were within ±1.5 % of the measured EERs. The methods used for system rating on the two-speed system can also be applied to a variable-speed system.
"synopsis" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 21615067
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 21615067-n
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Print on Demand. Seller Inventory # I-9781497334786
Seller: THE SAINT BOOKSTORE, Southport, United Kingdom
Paperback / softback. Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Seller Inventory # C9781497334786
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 21615067
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 21615067-n
Quantity: Over 20 available
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. A linear-fit method of rating residential-type air conditioning systems was evaluated based on performance predictions and laboratory testing of one two-speed matched system and two mixed systems (matched two-speed condensing unit, matched indoor coil blower, and two mixed coil blowers). The individual evaporators and the condensing unit were separately tested using water heated/cooled condensing/evaporating units at standard air conditions over a range of evaporator refrigerant saturation temperatures, evaporator superheats, and liquid refrigerant temperatures. Capacity predictions were within 1.0 % of the tested values for the mixed systems, and the EER predictions were within 1.5 % of the measured EERs. The methods used for system rating on the two-speed system can also be applied to a variable-speed system. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Seller Inventory # 9781497334786
Quantity: 1 available