A series of experiments are described in which helium was released at constant rates into a 1.5 m 1.5 m 0.75 m enclosure designed as a -scale model of a two car garage. The purpose was to provide reference data sets for testing and validating computational fluid dynamics (CFD) models and to experimentally characterize the effects of a number of variables on the mixing behavior within an enclosure and the exchange of helium with the surroundings. Helium was used as a surrogate for hydrogen, and the total volume released was scaled as the amount that could be released by a typical hydrogen-fueled automobile with a full fuel tank. Temporal profiles of helium were measured at seven vertical locations within the enclosure during and following one hour and four hour releases. Idealized vents in one wall sized to provide air exchange rates typical of actual garages were used. The effects of vent size, number, and location were investigated using three different vent combinations. The dependence on leak location was considered by releasing helium from three different points within the enclosure. A number of tabulated quantitative measures are used to characterize the experiments. The complete experimental measurement results for each condition are available on the internet as described in Appendix A (http://www.nist.gov/el/fire_protection/buildings/upload/HeliumDispersionDataSets.zip.)
"synopsis" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 21171539
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 21171539-n
Seller: California Books, Miami, FL, U.S.A.
Condition: New. Print on Demand. Seller Inventory # I-9781496168696
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 21171539
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 21171539-n
Quantity: Over 20 available
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. A series of experiments are described in which helium was released at constant rates into a 1.5 m 1.5 m 0.75 m enclosure designed as a -scale model of a two car garage. The purpose was to provide reference data sets for testing and validating computational fluid dynamics (CFD) models and to experimentally characterize the effects of a number of variables on the mixing behavior within an enclosure and the exchange of helium with the surroundings. Helium was used as a surrogate for hydrogen, and the total volume released was scaled as the amount that could be released by a typical hydrogen-fueled automobile with a full fuel tank. Temporal profiles of helium were measured at seven vertical locations within the enclosure during and following one hour and four hour releases. Idealized vents in one wall sized to provide air exchange rates typical of actual garages were used. The effects of vent size, number, and location were investigated using three different vent combinations. The dependence on leak location was considered by releasing helium from three different points within the enclosure. A number of tabulated quantitative measures are used to characterize the experiments. The complete experimental measurement results for each condition are available on the internet as described in Appendix A _protection/buildings/upload/HeliumDispersionDataSets.zip. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Seller Inventory # 9781496168696
Quantity: 1 available
Seller: THE SAINT BOOKSTORE, Southport, United Kingdom
Paperback / softback. Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Seller Inventory # C9781496168696
Quantity: Over 20 available