This report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 °C (500 °F) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved.
"synopsis" may belong to another edition of this title.
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: As New. Unread book in perfect condition. Seller Inventory # 21157391
Seller: THE SAINT BOOKSTORE, Southport, United Kingdom
Paperback / softback. Condition: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Seller Inventory # C9781496136602
Quantity: Over 20 available
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: As New. Unread book in perfect condition. Seller Inventory # 21157391
Quantity: Over 20 available
Seller: GreatBookPrices, Columbia, MD, U.S.A.
Condition: New. Seller Inventory # 21157391-n
Seller: GreatBookPricesUK, Woodford Green, United Kingdom
Condition: New. Seller Inventory # 21157391-n
Quantity: Over 20 available
Seller: CitiRetail, Stevenage, United Kingdom
Paperback. Condition: new. Paperback. This report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 0C (500 0F) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Seller Inventory # 9781496136602
Quantity: 1 available