Milestones in the techniques and methodology of polypeptide structure determination include the determination of the sequence of insulin by Sanger in 1951 (I) and the introduction of the repeti- tive degradation of proteins with phenylisothiocyanate by Edman in 1959 (2). The automation of Edman chemistry (3) played a major role in the determination of polypeptide structures. Important modifications of Edman chemistry include the solid-phase approach by Laursen in 1971 (4) and the use of modified Edman reagents such as 4-N,N-dimethylaminoazobenzene-4'-isothiocy- ate (DABITC) for manual sequencing by Chang et al. (5) in 1976. A second major breakthrough in the analysis of polypeptides was automated amino acid analysis described by Spackman et al. in 1958 (6). However, during the period from 1975 to 1980, it became increasingly clear that the amount of material required for struc- tural analysis was more than could be easily isolated for the vast majority of proteins. The field was criticized for its lack of sensitive techniques for the analysis of growth factors, immune modulators, membrane receptors, and peptide hormones. In addition, very little had been done to modernize and improve the original instruments introduced in the mid-1960s. The first indications of improved instrumentation for Edman chemistry came from Wittmann-Liebold's laboratory (7), followed by the introduction of a "micro" sequencer by Hunkapiller and Hood in 1978 (8). The movement toward improved instrumentation culminated in the "gas"-phase sequencer of Hewick et al. (9) in 1981.
"synopsis" may belong to another edition of this title.
Seller: Ria Christie Collections, Uxbridge, United Kingdom
Condition: New. In. Seller Inventory # ria9781489941329_new
Quantity: Over 20 available
Seller: Kennys Bookshop and Art Galleries Ltd., Galway, GY, Ireland
Condition: New. Series: Biological Methods. Num Pages: 456 pages, biography. BIC Classification: PSB. Category: (P) Professional & Vocational. Dimension: 229 x 152 x 25. Weight in Grams: 697. . 2013. Softcover reprint of the original 1st ed. 1986. Paperback. . . . . Seller Inventory # V9781489941329
Seller: Revaluation Books, Exeter, United Kingdom
Paperback. Condition: Brand New. 475 pages. 9.10x6.00x1.09 inches. In Stock. Seller Inventory # x-1489941320
Quantity: 2 available
Seller: Books Puddle, New York, NY, U.S.A.
Condition: New. pp. 480. Seller Inventory # 26134186610
Seller: Kennys Bookstore, Olney, MD, U.S.A.
Condition: New. Series: Biological Methods. Num Pages: 456 pages, biography. BIC Classification: PSB. Category: (P) Professional & Vocational. Dimension: 229 x 152 x 25. Weight in Grams: 697. . 2013. Softcover reprint of the original 1st ed. 1986. Paperback. . . . . Books ship from the US and Ireland. Seller Inventory # V9781489941329
Seller: Majestic Books, Hounslow, United Kingdom
Condition: New. Print on Demand pp. 480 23:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on White w/Gloss Lam. Seller Inventory # 126368173
Quantity: 4 available
Seller: moluna, Greven, Germany
Condition: New. Microisolation Techniques.- Microisolation of Biologically Active Polypeptides by Reverse-Phase Liquid Chromatography.- Reverse-Phase HPLC Isolation and Microsequence Analysis.- Purification of Microgram Quantities of Proteins by Polyacrylamide Gel Electrop. Seller Inventory # 4212232
Quantity: Over 20 available
Seller: Biblios, Frankfurt am main, HESSE, Germany
Condition: New. PRINT ON DEMAND pp. 480. Seller Inventory # 18134186616
Seller: AHA-BUCH GmbH, Einbeck, Germany
Taschenbuch. Condition: Neu. Neuware - Milestones in the techniques and methodology of polypeptide structure determination include the determination of the sequence of insulin by Sanger in 1951 (I) and the introduction of the repeti tive degradation of proteins with phenylisothiocyanate by Edman in 1959 (2). The automation of Edman chemistry (3) played a major role in the determination of polypeptide structures. Important modifications of Edman chemistry include the solid-phase approach by Laursen in 1971 (4) and the use of modified Edman reagents such as 4-N,N-dimethylaminoazobenzene-4'-isothiocy- ate (DABITC) for manual sequencing by Chang et al. (5) in 1976. A second major breakthrough in the analysis of polypeptides was automated amino acid analysis described by Spackman et al. in 1958 (6). However, during the period from 1975 to 1980, it became increasingly clear that the amount of material required for struc tural analysis was more than could be easily isolated for the vast majority of proteins. The field was criticized for its lack of sensitive techniques for the analysis of growth factors, immune modulators, membrane receptors, and peptide hormones. In addition, very little had been done to modernize and improve the original instruments introduced in the mid-1960s. The first indications of improved instrumentation for Edman chemistry came from Wittmann-Liebold's laboratory (7), followed by the introduction of a 'micro' sequencer by Hunkapiller and Hood in 1978 (8). The movement toward improved instrumentation culminated in the 'gas'-phase sequencer of Hewick et al. (9) in 1981. Seller Inventory # 9781489941329
Seller: Mispah books, Redhill, SURRE, United Kingdom
Paperback. Condition: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Seller Inventory # ERICA77314899413206
Quantity: 1 available